§431.2. Containers and closures. — Inbound Citations
9 C.F.R. § 431.2
Statutory Authority
Cited by 1 regulation in release Current.
Citations to 9 C.F.R. § 431.2 as a whole
-
(A) (1) For cylindrical containers, measure the following dimensions (Figure 1 to § 431.2) at three points approximately 120 degrees apart on the double seam excluding and at least one-half inch from the side seam juncture:(i) Double seam length—W;(ii) Double seam thickness—S;(iii) Body hook length—BH; and(iv) Cover hook length—CH.(2) Maximum and minimum values for each dimensional measurement must be recorded by the closure technician.