§1755.910. RUS specification for outside plant housings and serving area interface systems.
7 C.F.R. § 1755.910
(1) 3% sulfuric acid;
(2) 100 parts per million (ppm) trichloroethane in water;
(3) 0.2 N sodium hydroxide; and
(4) Unleaded high octane gasoline.
(2) The housing shall remain in its original mounting position throughout the test and exhibit no mechanical deformation.
(3) Figure 4 is as follows:
(2) The housing shall remain in its original mounting position throughout the test and exhibit no mechanical deformation.
(3) Figure 5 is as follows:
(1) The packaged housing and contents shall be placed on its normal shipping base with one corner supported 15 cm (6 in.) above the floor and the other corner of the same end supported 30 cm (12 in.) above the floor as shown in Figure 9. The unsupported end of the package shall be raised so that the lowest corner reaches the height listed above and then allowed to fall freely. Figure 9 is as follows:
(2) The procedure of paragraph (e)(4)(iv)(B)(1) of this section shall be repeated for the diagonally opposite corner.
(3) The packaged housing and contents shall be capable of enduring a single drop on each edge of the base of its normal shipping position from the required height without damage and shall remain operational without function impairment. The packaged housing and contents shall be placed on its base with one edge supported on a sill 15 cm (6 in.) high and the unsupported edge raised to the required height as shown in Figure 10 and allowed to fall freely. Figure 10 is as follows:
(4) The procedure of (e)(4)(iv)(B)(3) of this section shall be repeated for all edges of the base.
(2) Figure 11 is as follows:
Notes, amendments, and revision history
Amendments
[59 FR 53044, Oct. 21, 1994, as amended at 69 FR 18803, Apr. 9, 2004]
Authority
Authority: 7 U.S.C. 901 et seq., 1921 et seq., 6941 et seq.
Source
Source: 55 FR 39397, Sept. 27, 1990, unless otherwise noted.
Amendments
[59 FR 53044, Oct. 21, 1994, as amended at 69 FR 18803, Apr. 9, 2004]