§1755.522. RUS general specification for digital, stored program controlled central office equipment.
7 C.F.R. § 1755.522
(1) Test for bridged foreign electromotive force (EMF);
(2) Test for regular line battery;
(3) Test for booster battery voltage and polarity using the test shoe;
(4) Test for open circuits, short, tip ground, and ring ground;
(5) Test for tip or ring negative potential;
(6) Test for capacitance of a subscriber's line;
(7) Supply talking battery to the line with and without booster battery;
(8) Ring the subscriber through the test access circuit or through a test shoe;
(9) Test in and out of the central office; and
(10) Supply a reverse polarity key for voltage readings, except when positive or negative values are displayed directly.
(1) In a central office switching system of 400 or more equipped lines, a single nonduplicated ringing source failure shall not cause the complete loss of ringing capability to more than 100 lines.
(2) In a central office switching system of less than 400 equipped lines, a single nonredundant ringing source failure shall not cause the complete loss of ringing capability to more than 25 percent of the total equipped lines.
(1) In a remote switching terminal (RST) of 400 or more equipped lines, a single nonduplicated ringing source failure shall not cause the complete loss of ringing capability to more than 100 lines.
(2) In a remote switching terminal (RST) of less than 400 equipped lines, a single nonredundant ringing source failure shall not cause the complete loss of ringing capability to more than 25 percent of the total equipped lines.
(1) The failure of any single nonduplicated power converter shall not reduce the grade of service of common control and service circuits to any individual line or trunk by more than 50 percent.
(2) The failure of any single nonduplicated power converter shall not reduce the traffic carrying capacity of any trunk group or service links to a host office by more than 50 percent.
(3) In a remote switching terminal (RST) of 400 or more equipped lines, any single nonduplicated power converter failure shall not cause a complete loss of service to more than 100 equipped lines.
(4) In a remote switching terminal (RST) of less than 400 equipped lines, any single nonduplicated power converter failure shall not cause a complete loss of service to more than 25 percent of the total equipped lines.
8.1 Interoffice Trunking
Notes, amendments, and revision history
Amendments
[58 FR 30938, May 28, 1993; 58 FR 36252, July 6, 1993, as amended at 60 FR 1711, Jan. 5, 1995, 60 FR 64312, 64314, Dec. 15, 1995; 69 FR 18803, Apr. 9, 2004]
Authority
Authority: 7 U.S.C. 901 et seq., 1921 et seq., 6941 et seq.
Source
Source: 55 FR 39397, Sept. 27, 1990, unless otherwise noted.