§192.375. Service lines: Plastic.
49 C.F.R. § 192.375
Each plastic service line outside a building must be installed below ground level, except that—
It may be installed in accordance with § 192.321(g); and
It may terminate above ground level and outside the building, if—
The above ground level part of the plastic service line is protected against deterioration and external damage;
The plastic service line is not used to support external loads; and
The riser portion of the service line meets the design requirements of § 192.204.
Each plastic service line inside a building must be protected against external damage.