§192.241. Inspection and test of welds. — Inbound Citations
49 C.F.R. § 192.241
Statutory Authority
Cited by 5 regulations in release Current.
Citations to 49 C.F.R. § 192.241 as a whole
Citations to §192.241(b)
-
(d) When nondestructive testing is required under § 192.241(b), the following percentages of each day's field butt welds, selected at random by the operator, must be nondestructively tested over their entire circumference:(3) In Class 3 and Class 4 locations, at crossings of major or navigable rivers, offshore, and within railroad or public highway rights-of-way, including tunnels, bridges, and overhead road crossings, 100 percent unless impracticable, in which case at least 90 percent. Nondestructive testing must be impracticable for each girth weld not tested.
Citations to §192.241(c)
-
(c) Procedures must be established for the proper interpretation of each nondestructive test of a weld to ensure the acceptability of the weld under § 192.241(c).
-
(a) Each weld that is unacceptable under § 192.241(c) must be removed or repaired. Except for welds on an offshore pipeline being installed from a pipeline vessel, a weld must be removed if it has a crack that is more than 8 percent of the weld length.
-
Each weld that is unacceptable under § 192.241(c) must be repaired as follows: