US Codex
C.F.R.
Browse by date
Notes

§192.715. Transmission lines: Permanent field repair of welds.

49 C.F.R. § 192.715

Each weld that is unacceptable under § 192.241(c) must be repaired as follows:
(a)
If it is feasible to take the segment of transmission line out of service, the weld must be repaired in accordance with the applicable requirements of § 192.245.
(b)
A weld may be repaired in accordance with § 192.245 while the segment of transmission line is in service if:
(1)
The weld is not leaking;
(2)
The pressure in the segment is reduced so that it does not produce a stress that is more than 20 percent of the SMYS of the pipe; and
(3)
Grinding of the defective area can be limited so that at least 1/8-inch (3.2 millimeters) thickness in the pipe weld remains.
(c)
A defective weld which cannot be repaired in accordance with paragraph (a) or (b) of this section must be repaired by installing a full encirclement welded split sleeve of appropriate design.
Notes, amendments, and revision history

Amendments

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-85, 63 FR 37504, July 13, 1998]

Authority

Authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et. seq., and 49 CFR 1.97.

Source

Source: 35 FR 13257, Aug. 19, 1970, unless otherwise noted.

Amendments

[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-85, 63 FR 37504, July 13, 1998]