§160.151-35. Servicing.

46 C.F.R. § 160.151-35

(a)
Inspection and repair. Inflatable liferafts carried under the regulations in this chapter, and in chapter I of title 33 CFR, must be inspected periodically by a servicing facility approved by the Coast Guard, repaired as necessary, and repacked. Requirements for periodic inspection and repair of liferafts approved by the Coast Guard appear in §§ 160.151-37 through 160.151-57.
(b)
Manufacturer's requirements. To retain Coast Guard approval of liferafts, the manufacturer must:
(1)
Prepare a servicing manual or manuals complying with § 160.151-37 to cover each model and size of liferaft that the manufacturer produces. The manual or manuals must be submitted to the Commandant for approval.
(2)
At least once each year, issue a list of revisions to the manual or manuals, and issue a list of bulletins affecting the manual or manuals, that are in effect.
(3)
Make available to each servicing facility approved by the Coast Guard the manual or manuals, the revisions, the bulletins, the plans, and any unique parts and tools that may be necessary to service the liferaft. The plans may be either the manufacturing drawings, or special plans prepared especially for use by servicing technicians. They may be incorporated into the manual or manuals.
(4)
Have a training program complying with § 160.151-39 for the certification of servicing technicians.
(5)
Notify the OCMI for the zone in which the servicing facility is located whenever the manufacturer becomes aware of servicing at approved facilities that is not in accordance with the requirements of this subpart, or aware of falsification by an approved facility of records required by this subpart.
(c)
A manufacturer of liferafts not approved by the Coast Guard may establish servicing facilities approved by the Coast Guard for such liferafts in the United States if the manufacturer meets the requirements of paragraph (b) of this section.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-37. Servicing manual.

46 C.F.R. § 160.151-37

(a)
The servicing manual must provide instructions on performing the following tasks:
(1)
Removing the inflatable liferaft from the container for testing without damaging the liferaft or its contents.
(2)
Examining the liferaft and its container for damage and wear including deteriorated structural joints and seams.
(3)
Determining the need for repairs.
(4)
Performing each repair which can be made by a servicing facility.
(5)
Identifying repairs that the manufacturer must perform.
(6)
Determining when liferaft equipment must be replaced.
(7)
Conducting tests required by § 160.151-57.
(8)
Repacking the liferaft.
(9)
Changing the maximum height of stowage of the liferaft by changing the length of the painter.
(10)
Special equipment limitations or packing instructions, if any, necessary to qualify the liferaft for a particular height of stowage.
(11)
Changing the service of the liferaft by changing the contents of the equipment pack.
(12)
Proper marking of the liferaft container, including approval number, persons' capacity, maximum height of stowage, service (equipment pack), and expiration date of servicing.
(13)
A list of parts for—
(i)
Survival equipment;
(ii)
Compressed-gas cylinders;
(iii)
Inflation valves;
(iv)
Relief valves; and
(v)
Repair equipment.
(14)
The necessary pressures for each size of approved liferaft for conducting the “Necessary Additional Pressure” test required by § 160.151-57(k).
(b)
Each revision to a servicing manual, and each bulletin, that authorizes the modification of a liferaft, or that affects the compliance of a liferaft with any requirement under this subpart, must be submitted to and approved by the Commandant. Other revisions and bulletins need not be approved, but a copy of each must be submitted to the Commandant when issued.
(c)
Each manual provided under this section must bear the original signature of a representative of the manufacturer attesting that it is a true copy of the manual approved by the Commandant.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-39. Training of servicing technicians.

46 C.F.R. § 160.151-39

(a)
The training program for certification of servicing technicians must include—
(1)
Training and practice in packing an inflatable liferaft, repairing buoyancy tubes, repairing inflation-system valves, and other inspections and operations described in the approved servicing manual;
(2)
An evaluation at the end of the training to determine whether each trainee has successfully completed the training; and
(3)
Issuance of a certificate of competence to each technician who successfully completes the training.
(b)
The manufacturer shall maintain refresher training for recertification of previously trained servicing technicians. This training must include—
(1)
Checking the performance of the technicians in the inspections and operations described in the manual;
(2)
Retraining of the technicians in inspections and operations for which they are deficient;
(3)
Training and practice in new inspections and operations;
(4)
An evaluation at the end of the training to determine whether or not each trainee has successfully completed the training; and
(5)
Issuance of a certificate of competence to each technician who successfully completes the training.
(c)
Each time the manufacturer holds a course for servicing technicians who will perform servicing on liferafts approved by the Coast Guard, the manufacturer shall notify the cognizant OCMI sufficiently in advance to allow, at the option of the OCMI, for a Coast Guard inspector or inspectors to travel to the site where the training is to occur.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-41. Approval of servicing facilities.

46 C.F.R. § 160.151-41

(a)
To obtain and maintain Coast Guard approval as an “approved servicing facility” for a particular manufacturer's inflatable liferafts, a facility must meet the requirements, and follow the procedures, of this section.
(b)
The owner or operator of a servicing facility desiring Coast Guard approval shall apply to the cognizant OCMI. The application must include—
(1)
The name and address of the facility;
(2)
The name(s) of its competent servicing technician(s);
(3)
Identification of the manufacturer(s) of the liferafts the facility will service; and
(4)
Any limits or special conditions that should apply to the approval of the facility.
(c)
The owner or operator of the servicing facility shall arrange for an inspection with the OCMI to whom the owner or operator applied under paragraph (b) of this section. A currently trained servicing technician shall successfully demonstrate the complete service to each make and type of liferaft for which approval as a servicing facility is sought, in the presence of a Coast Guard inspector or of a third-party inspector accepted by the OCMI, or such technician shall present evidence of having performed such service at the time of initial or refresher training. The service must include:
(1)
Removing the liferaft from the container for testing without damaging the liferaft or its contents;
(2)
Examining the liferaft and its container for damage and wear;
(3)
Determining the need for repairs;
(4)
Determining whether equipment must be replaced;
(5)
Conducting the tests required by § 160.151-57;
(6)
Repacking the liferaft;
(7)
Inflating the fully packed liferaft using its inflation mechanism; and
(8)
Repairing a leak in a main buoyancy chamber, and subjecting the repaired chamber to the Necessary Additional Pressure test described in § 160.151-57(k). This repair may be done on a liferaft that actually needs it, on one condemned, or on an inflatable chamber fabricated of liferaft material specifically for this purpose. (An otherwise serviceable liferaft should not be damaged for this purpose.)
(d)
Whenever servicing of liferafts takes place, each servicing facility must allow Coast Guard inspectors or third-party inspectors accepted by the OCMI access to the place where the servicing occurs.
(e)
Each servicing facility must employ at least one servicing technician who has successfully completed the manufacturer's training described in § 160.151-39 (a) or (b), including training in the servicing of davit-launched liferafts if the facility will service these. The training must have been completed within the preceding—
(1)
12 months for the facility to obtain its approval to service the liferafts of a particular manufacturer; or
(2)
36 months for the facility to retain approval to service the liferafts of a particular manufacturer.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-43. Conditions at servicing facilities.

46 C.F.R. § 160.151-43

(a)
Each facility must maintain a room to service inflatable liferafts that—
(1)
Is clean;
(2)
Is fully enclosed;
(3)
Has enough space to service the number of liferafts likely to be present for service at one time;
(4)
Has a ceiling high enough to hold and allow overturning of a fully inflated liferaft of the largest size to be serviced, or is furnished with an equally efficient means to facilitate the inspection of bottom seams;
(5)
Has a smooth floor that will not damage a liferaft, can be easily cleaned, and is kept clean and free from oil, grease, and abrasive material;
(6)
Is well lit but free from direct sunlight;
(7)
Is arranged to maintain an even temperature and low humidity in each area where liferafts are pressure tested, including by mechanical air-conditioning equipment in climates where it is necessary;
(8)
Is arranged so that stored liferafts are not subjected to excessive loads and, if stacked one directly on top of another, does not have them stacked more than two liferafts high;
(9)
Is efficiently ventilated but free of drafts; and
(10)
Is a designated no-smoking area.
(b)
In addition to the room required by paragraph (a) of this section, each facility must maintain areas or rooms for storage of liferafts awaiting servicing, repair, or delivery; for repair and painting of reinforced plastic containers; for storage of pyrotechnics and other materials, such as spare parts and required equipment; and for administrative purposes.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-45. Equipment required for servicing facilities.

46 C.F.R. § 160.151-45

Each servicing facility approved by the Coast Guard must maintain equipment to carry out the operations described in the manufacturer's servicing manual approved in accordance with § 160.151-35(b)(1), including—
(a)
A set of plans, as specified in § 160.151-35(b)(3), for each inflatable liferaft to be serviced;
(b)
A current copy of this subpart;
(c)
A current copy of the manual approved in accordance with § 160.151-35(b)(1), including all revisions and bulletins in effect as indicated on the annual list issued in accordance with § 160.151-35(b)(2);
(d)
Hot presses (if applicable);
(e)
Safety-type glue pots or equivalents;
(f)
Abrasive devices;
(g)
A source of clean, dry, pressurized air; hoses; and attachments for inflating liferafts;
(h)
A source of vacuum; hoses; and attachments for deflating liferafts;
(i)
Mercury manometer, water manometer, or other pressure-measurement device or pressure gauge of equivalent accuracy and sensitivity;
(j)
Thermometer;
(k)
Barometer, aneroid or mercury;
(l)
Calibrated torque-wrench for assembling the inflation system;
(m)
Accurate weighing scale;
(n)
Repair materials and equipment, and spare parts as specified in the applicable manual, except that items of limited “shelf life” need not be stocked if they are readily available;
(o)
A complete stock of the survival equipment required to be stowed in the liferafts, except for items of equipment that are readily available;
(p)
A means for load-testing davit-launched liferafts, unless the facility services only non-davit-launched liferafts;
(q)
A supply of parts for all inflation components and valves specified in the applicable manual; and
(r)
A tool board that clearly indicates where each small tool is stored, or has an equivalent means to make sure that no tools are left in the liferaft when repacked.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-47. Requirements for owners or operators of servicing facilities.

46 C.F.R. § 160.151-47

To maintain Coast Guard approval, the owner or operator of each servicing facility approved by the Coast Guard must—
(a)
Ensure that servicing technicians have received sufficient information and training to follow instructions for changes and for new techniques related to the inflatable liferafts serviced by the facility, and have available at least one copy of each manufacturer's approved servicing manual, revision, and bulletin;
(b)
Calibrate each pressure gauge, mechanically-operated barometer, and weighing scale at intervals of not more than 1 year, or in accordance with the equipment manufacturer's requirements;
(c)
Ensure that each liferaft serviced under the facility's Coast Guard approval is serviced by or under the direct supervision of a servicing technician who has completed the requirements of either § 160.151-39 (a) or (b);
(d)
Ensure that each liferaft serviced under the facility's Coast Guard approval is serviced in accordance with the approved manual;
(e)
Specify which makes of liferafts the facility is approved to service when representing that the facility is approved by the Coast Guard; and
(f)
Ensure that the facility does not service any make of liferaft for an inspected vessel of the U.S. or any other U.S.-flag vessel required to carry approved liferafts, unless the facility is approved by the Coast Guard to service that make of liferafts.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-49. Approval of servicing facilities at remote sites.

46 C.F.R. § 160.151-49

A servicing facility may be approved for servicing liferafts at a remote site, provided that appropriate arrangements have been made to ensure that each such site meets the requirements of §§ 160.151-41(e), 160.151-43, and 160.151-45. The facility must have a portable assortment of test equipment, spare parts, and replacement survival equipment to accompany the technician doing the servicing. However, if repair of liferafts will not be attempted at a remote site, equipment needed for repair does not need to be available at that site. A facility must be specifically authorized in its letter of approval to conduct servicing at a remote site.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-51. Notice of approval.

46 C.F.R. § 160.151-51

If the cognizant OCMI determines that the servicing facility meets the applicable requirements of §§ 160.151-39 through 160.151-47, the OCMI notifies the facility that it is approved and notifies the Commandant. The Commandant issues an approval letter to the servicing facility with copies to the OCMI and to the manufacturer(s) whose liferafts the facility is approved to service. The letter will specify any limits on the approval, and will assign the facility's approval code for use on the inspection sticker required by § 160.151-57(m)(3). The Commandant will maintain a current list of approved facilities.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-53. Notice to OCMI of servicing.

46 C.F.R. § 160.151-53

(a)
Before servicing an inflatable liferaft under the servicing facility's Coast Guard approval, the owner or operator of the facility must tell the cognizant OCMI for each liferaft to be serviced—
(1)
The make and size of the liferaft;
(2)
The age of the liferaft; and
(3)
Whether the liferaft is due for a five-year inflation test.
(b)
The OCMI will inform the servicing facility whether the servicing of the liferaft must be witnessed by an inspector.
(c)
If the OCMI requires the servicing of the liferaft to be witnessed by an inspector—
(1)
The servicing facility must arrange a schedule with the OCMI that will allow a Coast Guard inspector to travel to the site where the servicing is to occur;
(2)
The owner or operator of the servicing facility, by permission of the OCMI, may arrange for the servicing to be witnessed instead by a third-party inspector accepted by the OCMI if a Coast Guard marine inspector is not available in a timely manner; and
(3)
The servicing facility must not begin servicing the liferaft until the inspector arrives at the site.
(d)
No deviation from servicing-manual procedures may occur without the prior approval of the OCMI. To request the approval of a deviation, the owner or operator of the servicing facility shall notify the OCMI of the proposed deviation from the procedures, and must explain to the OCMI the need for the deviation.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-55. Withdrawal of approval.

46 C.F.R. § 160.151-55

(a)
The OCMI may withdraw the approval of the servicing facility, or may suspend its approval pending correction of deficiencies, if the Coast Guard inspector or accepted third-party inspector finds that—
(1)
The facility does not meet the requirements of §§ 160.151-41 through 160.151-47, or
(2)
The servicing is not performed in accordance with § 160.151-57.
(b)
A withdrawal of approval may be appealed in accordance with part 1, subpart 1.03, of this chapter.
(c)
The OCMI may remove a suspension pending correction of deficiencies if the servicing facility demonstrates that the deficiencies have been corrected.
Notes, amendments, and revision history

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

§160.151-57. Servicing procedure.

46 C.F.R. § 160.151-57

(a)
Each inflatable liferaft serviced by a servicing facility approved by the Coast Guard must be inspected and tested in accordance with paragraphs (b) through (r) of this section, and the manufacturer's servicing manual approved in accordance with § 160.151-35(b)(1).
(b)
The following procedures must be carried out at each servicing:
(1)
The working-pressure leakage test described in IMO Revised recommendation on testing, as amended by Resolution MSC.295(87), paragraph 2/5.1.5 (incorporated by reference, see § 160.151-5 of this subpart), must be conducted.
(2)
Inflation hoses must be pressurized and checked for damage and leakage as part of the working-pressure leakage test, or in a separate test.
(3)
An inflatable floor must be inflated until it is firm, and let stand for one hour. The inflatable floor must still be firm at the end of the hour.
(4)
The seams connecting the floor to the buoyancy tube must be checked for slippage, rupture, and lifting of edges.
(5)
Each item of survival equipment must be examined, and—
(i)
Replaced at the time of servicing if there is less than 6 months remaining before the expiration date; and
(ii)
Otherwise, repaired or replaced if it is damaged or unserviceable.
(6)
Each battery must be replaced with a fresh one if—
(i)
Its expiration date has passed;
(ii)
It has no expiration date; or
(iii)
It is to return to service in an item of survival equipment, but its measured voltage is less than its rated voltage.
(7)
Each power cell for the top and inside canopy lights must be inspected and tested as prescribed in the servicing manual unless it is a battery serviced in accordance with paragraph (b)(6) of this section. Each cell that is tested and found satisfactory may be reinstalled. Each cell that is outdated, is not tested, or fails the test must be replaced.
(8)
If the liferaft is equipped with an Emergency Position-Indicating Radio Beacon (EPIRB) or a Search and Rescue Transmitter (SART), the EPIRB or SART must be inspected and tested in accordance with the manufacturer's instructions. An EPIRB must be tested using the integrated test circuit and output indicator to determine whether it is operative. Each EPIRB or SART not operative must be repaired or replaced.
(9)
The manual inflation-pump must be tested for proper operation.
(10)
Each damaged, faded, or incorrect instruction label or identification label on the liferaft or its container must be replaced.
(11)
Each liferaft must be examined to ensure that it is properly marked with retroreflective material. The arrangement of the retroreflective material must meet the requirements of IMO Revised recommendation on testing, as amended by Resolution MSC.295(87). Damaged or missing retroreflective material must be replaced with Type I material approved under 46 CFR part 164, subpart 164.018, as complying with SOLAS.
(12)
Each inflation cylinder must be weighed. If its weight loss exceeds five percent of the weight of the charge, it must be recharged.
(c)
When an inflation cylinder is recharged for any reason, the following inflation-head components must be renewed:
(1)
The poppet-pin assembly, if any.
(2)
Each plastic or elastomeric seal, and each other part that deteriorates with age.
(d)
Each recharged inflation cylinder must stand for at least two weeks and be checked for leakage by weighing before being installed in a liferaft. An alternative mechanical or chemical test for fast detection of leakage may be used if the servicing manual approved by the Commandant in accordance with § 160.151-35(b)(1) provides for it.
(e)
Each inflation cylinder that requires a hydrostatic test under 49 CFR 180.205 must be tested and marked in accordance with that section.
(f)
At every second servicing of a davit-launched liferaft, the launching-load test in paragraph 2/5.2 of IMO Revised recommendation on testing, as amended by Resolution MSC.295(87) must be conducted.
(g)
At every fifth annual servicing, before the conduct of the tests and inspections required in paragraphs (b) through (f) of this section, each liferaft must be removed from its container and, while still folded, inflated by the operation of its gas-inflation system.
(h)
Each liferaft showing minor leaks during the gas inflation test conducted in accordance with paragraph (g) of this section, may be repaired.
(i)
Each liferaft ten or more years past its date of manufacture must be condemned if it leaks extensively, or shows fabric damage other than minor porosity, during the gas inflation test conducted in accordance with paragraph (g) of this section.
(j)
After the gas inflation test conducted in accordance with paragraph (g) of this section, the liferaft may be evacuated and refilled with air for the tests in paragraphs (b) through (f) of this section.
(k)
At each annual servicing of a liferaft ten or more years past its date of manufacture during which the gas-inflation test in paragraph (g) of this section is not conducted, a “Necessary Additional Pressure” (NAP) test must be conducted. Before the tests and inspections required in paragraphs (b) through (f) of this section are conducted, the NAP test must be completed, using the following procedure:
(1)
Plug or otherwise disable the pressure-relief valves.
(2)
Gradually raise the pressure to the lesser of 2 times the design working pressure, or that specified in the manufacturer's servicing manual as sufficient to impose a tensile load on the tube fabric of 20 percent of its minimum required tensile strength.
(3)
After 5 minutes, there should be no seam slippage, cracking, other defects, or pressure drop greater than 5 percent. If cracking in the buoyancy tubes is audible, accompanied by pressure loss, condemn the liferaft. If it is not, reduce the pressure in all buoyancy chambers simultaneously by enabling the pressure-relief valves.
(l)
At each annual servicing of a liferaft 10 or more years past its date of manufacture, the integrity of the seams connecting the floor to the buoyancy tube must be checked by the following procedure, or an equivalent procedure specified in the manufacturer's approved servicing manual:
(1)
With the buoyancy tube supported a sufficient distance above the floor of the servicing facility to maintain clearance during the test, a person weighing not less than 75 kg (165 lb) shall walk or crawl around the entire perimeter of the floor of the liferaft.
(2)
The seams connecting the floor to the buoyancy tube must then be inspected for slippage, rupture, and lifting of edges.
(m)
The servicing facility must complete the following for each liferaft that passes these inspections and tests:
(1)
Permanently mark the liferaft on its outside canopy, or on a servicing-record panel on an interior portion of one of its buoyancy tubes near an entrance, with—
(i)
The date of the servicing;
(ii)
The identification and location of the servicing facility; and
(iii)
If applicable, an indication that the special fifth-year servicing was performed.
(2)
Permanently and legibly mark on the identification device provided in accordance with § 160.151-17(c), or on the outside canopy of the liferaft, the name, if known, of the vessel on which the raft will be installed or the name, if known, of the vessel owner.
(3)
Affix an inspection sticker to the liferaft container or valise. The sticker must be of a type that will remain legible for at least 2 years when exposed to a marine environment, and that cannot be removed without being destroyed. The sticker must be about 100 mm × 150 mm (4 by 6 inches), with the last digit of the year of expiration superimposed over a background color that corresponds to the colors specified for the validation stickers for recreational-boat numbers in 33 CFR 174.15(c), and be marked with the Coast Guard identifying insignia in accordance with the requirements of 33 CFR 23.12. The sticker must also contain the following:
(i)
The name of the manufacturer of the liferaft.
(ii)
The year and month of expiration determined in accordance with paragraph (n) of this section.
(iii)
Identification of the servicing facility, printed on the sticker or indicated on the sticker by punch using an approval code issued by the Commandant.
(n)
The expiration date of the servicing sticker is 12 months after the date the liferaft was repacked, except that:
(1)
For a new liferaft, the expiration date may be not more than two years after the date the liferaft was first packed, if—
(i)
Dated survival equipment in the liferaft will not expire before the sticker expiration date; and
(ii)
The liferaft will not be installed on a vessel certificated under SOLAS.
(2)
For a liferaft stored indoors, under controlled temperatures (between 0 °C (32 °F) and 45 °C (113 °F)), for not more than 6 months from the date it was serviced or first packed, the expiration date may be extended up to the length of time the liferaft remained in storage.
(3)
For a liferaft stored indoors, under controlled temperatures (between 0 °C (32 °F) and 45 °C (113 °F)), for not more than 12 months from the date it was serviced or first packed, the expiration date may be extended up to the length of time the liferaft remained in storage, if the liferaft is opened, inspected, and repacked in a servicing facility approved in accordance with §§ 160.151-49 and 160.151-51. When the liferaft is opened—
(i)
The condition of the liferaft must be visually checked and found to be satisfactory;
(ii)
The inflation cylinders must be checked and weighed in accordance with paragraph (b)(12) of this section;
(iii)
All survival equipment whose expiration date has passed must be replaced; and
(iv)
All undated batteries must be replaced.
(o)
The servicing facility must remove and destroy the markings of Coast Guard approval on each liferaft condemned in the course of any servicing test or inspection.
(p)
The servicing facility must issue a certificate to the liferaft owner or owner's agent for each liferaft it services. The certificate must include—
(1)
The name of the manufacturer of the liferaft;
(2)
The serial number of the liferaft;
(3)
The date of servicing and repacking;
(4)
A record of the fifth-year gas-inflation test required in paragraph (g) of this section, whenever that test is performed;
(5)
A record of the hydrostatic test of each inflation cylinder required in paragraph (e) of this section, whenever that test is performed;
(6)
A record of any deviation from the procedures of the manufacturer's servicing manual authorized by the OCMI in accordance with § 160.151-53(d);
(7)
The identification of the servicing facility, including its name, address, and the approval code assigned by the Commandant in accordance with § 160.151-51;
(8)
The name, if known, of the vessel or vessel owner receiving the liferaft; and
(9)
The date the liferaft is returned to the owner or owner's agent.
(q)
The servicing facility must keep a record of each liferaft approved by the Coast Guard that it services for at least five years, and must make those records available to the Coast Guard upon request. Those records must include—
(1)
The serial number of the liferaft;
(2)
The date of servicing and repacking;
(3)
The identification of any Coast Guard or third-party inspector present;
(4)
The name, if known, of the vessel or vessel owner receiving the liferaft; and
(5)
The date the liferaft is returned to the owner or owner's agent.
(r)
The servicing facility must prepare and transmit to the OCMI, at least annually, statistics showing the nature and extent of damage to and defects found in liferafts during servicing and repair. The facility must notify the OCMI immediately of any critical defects it finds that may affect other liferafts.
Notes, amendments, and revision history

Amendments

[CGD 85-205, 62 FR 25547, May 9, 1997, as amended by USCG-1998-4442, 63 FR 52192, Sept. 30, 1998; USCG-2010-0759, 75 FR 60004, Sept. 29, 2010, as amended by USCG-2010-0048, 76 FR 62999, Oct. 11, 2011; 77 FR 9865, Feb. 21, 2012]

Source

Source: CGD 85-205, 62 FR 25547, May 9, 1997, unless otherwise noted.

Authority

Authority: 46 U.S.C. 2103, 3306, 3703, 4302; E.O. 12234; 45 FR 58801; 3 CFR, 1980 Comp., p. 277; and DHS Delegation 00170.1, Revision No. 01.4.

Amendments

[CGD 85-205, 62 FR 25547, May 9, 1997, as amended by USCG-1998-4442, 63 FR 52192, Sept. 30, 1998; USCG-2010-0759, 75 FR 60004, Sept. 29, 2010, as amended by USCG-2010-0048, 76 FR 62999, Oct. 11, 2011; 77 FR 9865, Feb. 21, 2012]