Each restricted gauge that penetrates a cargo tank must have an excess flow valve unless the gauge meets § 154.536.
-
-
(a) Except those connections for tank safety relief valves and for liquid level gauging devices other than those under §§ 154.536 and 154.1310, liquid and vapor connections on a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have shut-off valves that—(1) Are located as close to the tank as practical;(2) Are capable of local manual operation; and
-
(a) Except connections for tank safety relief valves and except for liquid level gauging devices other than those under §§ 154.536 and 154.1310, liquid and vapor connections on a cargo tank with a MARVS greater than 69 kPa gauge (10 psig) must have, as close to the tank as practical, a:(1) Stop valve capable of local manual operation; and