§154.503. Piping and piping system components: Protection from movement.

46 C.F.R. § 154.503

Where thermal movement and movements of the cargo tank and the hull structure may cause stresses that exceed the design stresses, the piping and piping system components and cargo tanks must be protected from movement by:
(a)
Offsets;
(b)
Loops;
(c)
Bends;
(d)
Mechanical expansion joints including—
(1)
Bellows;
(2)
Slip joints;
(3)
Ball joints; or
(e)
Other means specially approved by the Commandant (CG-ENG).
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

§154.506. Mechanical expansion joint: Limits in a piping system.

46 C.F.R. § 154.506

Mechanical expansion joints in a piping system outside of a cargo tank:
(a)
May be installed only if offsets, loops or bends cannot be installed due to limited space or piping arrangement;
(b)
Must be a bellows type; and
(c)
Must not have insulation or a cover unless necessary to prevent damage.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.512. Piping: Thermal isolation.

46 C.F.R. § 154.512

Low temperature piping must be thermally isolated from any adjacent hull structure to prevent the temperature of that structure from dropping below the minimum temperature for the hull material under § 154.170.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.514. Piping: Electrical bonding.

46 C.F.R. § 154.514

(a)
Cargo tanks or piping that are separated from the hull structure by thermal isolation must be electrically bonded to the hull structure by a method under paragraph (c) of this section.
(b)
A pipe joint or a hose connection fitting that has a gasket must be electrically bonded by a method under paragraph (c) of this section that bonds:
(1)
Both sides of the connection to the hull structure; or
(2)
Each side of the connection to the other side.
(c)
An electrical bond must be made by at least one of the following methods:
(1)
A metal bonding strap attached by welding or bolting.
(2)
Two or more bolts that give metal to metal contact between the bolts and the parts to be bonded.
(3)
Metal to metal contact between adjacent parts under designed operating conditions.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.516. Piping: Hull protection.

46 C.F.R. § 154.516

A vessel's hull must be protected from low temperature liquid leakage by a drip pan, or other means specially approved by the Commandant (CG-ENG), at:
(a)
Each piping connection dismantled on a routine basis;
(b)
Cargo discharge and loading manifolds; and
(c)
Pump seals.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

§154.517. Piping: Liquid pressure relief.

46 C.F.R. § 154.517

The cargo loading and discharge crossover headers, cargo hoses, and cargo loading arms must have means to relieve cargo pressure and to remove liquid cargo.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.519. Piping relief valves.

46 C.F.R. § 154.519

(a)
The liquid relief valve that protects the cargo piping system from liquid pressure exceeding the design pressure must discharge into:
(1)
A cargo tank; or
(2)
A cargo vent mast if that vent mast has a means for the detection and removal of the liquid cargo that is specially approved by the Commandant (CG-ENG).
(b)
A relief valve on a cargo pump that protects the cargo piping system must discharge into the pump suction.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

§154.520. Piping calculations.

46 C.F.R. § 154.520

A piping system must be designed to meet the allowable stress values under § 56.07-10 of this chapter and, if the design temperature is −110 °C (−166 °F) or lower, the stress analysis must be specially approved by the Commandant (CG-ENG) and must include:
(a)
Pipe weight loads;
(b)
Acceleration loads;
(c)
Internal pressure loads;
(d)
Thermal loads; and
(e)
Loads from the hull.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

§154.522. Materials for piping.

46 C.F.R. § 154.522

(a)
The materials for piping systems must meet § 154.625 for the minimum design temperature of the piping, except the material for open ended vent piping may be specially approved by the Commandant (CG-ENG) if:
(1)
The temperature of the cargo at the pressure relief valve setting is −55 °C (−67 °F) or warmer; and
(2)
Liquid cannot discharge to the vent piping.
(b)
Materials for piping outside the cargo tanks must have a melting point of at least 925 °C (1697 °F), except for short lengths of pipes with fire resisting insulation that are attached to the cargo tanks.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by USCG-2014-0688, 79 FR 58285, Sept. 29, 2014]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by USCG-2014-0688, 79 FR 58285, Sept. 29, 2014]

§154.524. Piping joints: Welded and screwed couplings.

46 C.F.R. § 154.524

Pipe lengths without flanges must be joined by one of the following:
(a)
A butt welded joint with complete penetration at the weld root except that for design temperatures colder than −10 °C (14 °F) the butt weld must be double welded or must be welded using:
(1)
A backing ring that for design pressures greater than 979 kPa gauge (142 psig) must be removed after the weld is completed;
(2)
A consumable insert; or
(3)
An inert gas back-up on the first weld pass.
(b)
A slip-on welded joint with sleeves and attachment welds is allowed for an open ended pipe with an external diameter of 50 mm (2 in.) or less and a design temperature of −55 °C (−67 °F), or warmer.
(c)
A socket weld fitting with attachment welds is allowed for pipe with an external diameter of 50 mm (2 in.) or less and a design temperature of −55 °C (−67 °F) or warmer.
(d)
Screwed couplings are allowed for instrumentation and control piping that meets § 56.30-20 and § 56.50-105 (a)(4) and (b)(4) of this chapter.
(e)
A method or fitting specially approved by the Commandant (CG-ENG).
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

§154.526. Piping joints: Flange connection.

46 C.F.R. § 154.526

Flange connections for pipe joints must meet § 56.30-10 and § 56.50-105 (a)(4) and (b)(4) of this chapter.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.528. Piping joints: Flange type.

46 C.F.R. § 154.528

(a)
A flange must be one of the following types:
(1)
Welding neck.
(2)
Slip-on.
(3)
Socket weld.
(b)
If the piping is designed for a temperature between −10 °C (14 °F) and −55 °C (−67 °F), the pipe flange may be a:
(1)
Slip-on type, if the nominal pipe size is 100 mm (4 in.) or less;
(2)
Socket weld, if the nominal pipe size is 50 mm (2 in.) or less; or
(3)
Welding neck.
(c)
If the piping is designed for a temperature lower than −55 °C (−67 °F), the pipe flange must be a welding neck type.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.530. Valves: Cargo tank MARVS 69 kPa gauge (10 psig) or lower.

46 C.F.R. § 154.530

(a)
Except those connections for tank safety relief valves and for liquid level gauging devices other than those under §§ 154.536 and 154.1310, liquid and vapor connections on a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have shut-off valves that—
(1)
Are located as close to the tank as practical;
(2)
Are capable of local manual operation; and
(3)
May be remotely controlled.
(b)
The cargo piping system for a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have at least one remotely controlled quick-closing shut-off valve for closing liquid and vapor piping between vessel and shore that meets §§ 154.540 and 154.544.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 77-069, 52 FR 31630, Aug. 21, 1987]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 77-069, 52 FR 31630, Aug. 21, 1987]

§154.532. Valves: Cargo tank MARVS greater than 69 kPa gauge (10 psig).

46 C.F.R. § 154.532

(a)
Except connections for tank safety relief valves and except for liquid level gauging devices other than those under §§ 154.536 and 154.1310, liquid and vapor connections on a cargo tank with a MARVS greater than 69 kPa gauge (10 psig) must have, as close to the tank as practical, a:
(1)
Stop valve capable of local manual operation; and
(2)
A remotely controlled quick-closing shut-off valve.
(b)
If the nominal pipe size of a liquid or vapor connection is less than 50 mm (2 in.), an excess flow valve may be substituted for the quick-closing valve under paragraph (a) of this section.
(c)
One valve may be substituted for the manual controlled stop valve and the remotely controlled quick-closing shut-off valve required under paragraph (a) of this section if that valve:
(1)
Meets §§ 154.540 and 154.544; and
(2)
Is capable of local manual operation.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.534. Cargo pumps and cargo compressors.

46 C.F.R. § 154.534

Cargo pumps and cargo compressors must shut-down automatically when the quick-closing shut-off valves under §§ 154.530 and 154.532 are closed by the emergency shut-down system required under § 154.540.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.536. Cargo tank gauging and measuring connections.

46 C.F.R. § 154.536

Unless the outward flow from a cargo tank is less than the flow through a circular hole of 1.4 mm (0.055 in.) in diameter, cargo tank connections for gauging or measuring devices must have the excess flow, shut-off, or quick-closing shut-off valves under § 154.530 or § 154.532.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.538. Cargo transfer connection.

46 C.F.R. § 154.538

A cargo transfer connection must have a:
(a)
Remotely controlled quick-closing shut-off valve that meets §§ 154.540 and 154.544; or
(b)
Blank flange.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.540. Quick-closing shut-off valves: Emergency shut-down system.

46 C.F.R. § 154.540

The quick-closing shut-off valves under §§ 154.530, 154.532, and 154.538 must have an emergency shut-down system that:
(a)
Closes all the valves;
(b)
Is actuated by a single control in at least two locations remote from the quick-closing valves;
(c)
Is actuated by a single control in each cargo control station under § 154.320; and
(d)
Has fusible elements at each tank dome and cargo loading and discharge manifold that melt between 98 °C (208 °F) and 104 °C (220 °F) and actuate the emergency shut-down system.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.544. Quick-closing shut-off valves.

46 C.F.R. § 154.544

The quick-closing shut-off valve under §§ 154.530, 154.532 and 154.538 must:
(a)
Be a shut-off valve;
(b)
Close from the time of actuation in 30 seconds or less;
(c)
Be the fail-closed type; and
(d)
Be capable of local manual closing.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 77-069, 52 FR 31630, Aug. 21, 1987]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 77-069, 52 FR 31630, Aug. 21, 1987]

§154.546. Excess flow valve: Closing flow.

46 C.F.R. § 154.546

(a)
The rated closing flow of vapor or liquid cargo for an excess flow valve must be specially approved by the Commandant (CG-ENG).
(b)
An excess flow valve allowed under § 154.532(b) must close automatically at the rated closing flow.
Notes, amendments, and revision history

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

Amendments

[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]

§154.548. Cargo piping: Flow capacity.

46 C.F.R. § 154.548

Piping with an excess flow valve must have a vapor or liquid flow capacity that is greater than the rated closing flow under § 154.546.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.550. Excess flow valve: Bypass.

46 C.F.R. § 154.550

If the excess flow valve allowed under § 154.532(b) has a bypass, the bypass must be of 1.0 mm (0.0394 in.) or less in diameter.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.551. Cargo hose: General.

46 C.F.R. § 154.551

Each of the vessel's liquid and vapor cargo hose for loading or discharging cargo must meet §§ 154.552 through 154.562.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.552. Cargo hose: Compatibility.

46 C.F.R. § 154.552

Liquid and vapor cargo hoses must:
(a)
Not chemically react with the cargo; and
(b)
Withstand design temperature.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.554. Cargo hose: Bursting pressure.

46 C.F.R. § 154.554

Cargo hose that may be exposed to the pressure in the cargo tank, the cargo pump discharge, or the vapor compressor discharge must have a bursting pressure of at least five times the maximum working pressure on the hose during cargo transfer.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.556. Cargo hose: Maximum working pressure.

46 C.F.R. § 154.556

A cargo hose must have a maximum working pressure not less than the maximum pressure to which it may be subjected and at least 1034 kPa gauge (150 psig).
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.558. Cargo hose: Marking.

46 C.F.R. § 154.558

Each cargo hose must be marked with the:
(a)
Maximum working pressure; and
(b)
Minimum service temperature for service at other than ambient temperature.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.560. Cargo hose: Prototype test.

46 C.F.R. § 154.560

(a)
Each cargo hose must be of a type that passes a prototype test at a pressure of at least five times its maximum working pressure at or below the minimum service temperature.
(b)
Each cargo hose must not be the hose used in the prototype test.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.562. Cargo hose: Hydrostatic test.

46 C.F.R. § 154.562

Each cargo hose must pass a hydrostatic pressure test at ambient temperature of at least one and a half times its specified maximum working pressure but not more than two-fifths its bursting pressure.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source