§154.506. Mechanical expansion joint: Limits in a piping system.

46 C.F.R. § 154.506

Mechanical expansion joints in a piping system outside of a cargo tank:
(a)
May be installed only if offsets, loops or bends cannot be installed due to limited space or piping arrangement;
(b)
Must be a bellows type; and
(c)
Must not have insulation or a cover unless necessary to prevent damage.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source