§154.1145. Dry chemical supply.

46 C.F.R. § 154.1145

(a)
A vessel with a cargo carrying capacity less that 1000 m 3 (35,300 ft. 3) must have at least one self-contained dry chemical storage unit for the cargo area with an independent inert gas pressurizing source adjacent to each unit.
(b)
A vessel with a cargo carrying capacity of 1000 m 3 (35,300 ft. 3) or more must have at least two self-contained dry chemical storage units for the cargo area with an independent inert gas pressurizing source adjacent to each unit.
(c)
A vessel with bow and stern loading and discharge areas must have at least one self-contained dry chemical storage unit with an independent inert gas pressurizing source adjacent to the unit for each area.
(d)
Each dry chemical storage unit and associated piping must be designed for:
(1)
Sequential discharge of each hose line and each monitor for 45 seconds; and
(2)
Simultaneous discharge of all hose lines and monitors for 45 seconds.
(e)
Each fully charged dry chemical storage unit must have the greater of the following:
(1)
Enough dry chemical to provide for sequential discharge of each attached hose and monitor for 45 seconds.
(2)
Enough dry chemical to provide for simultaneous discharge of all attached hoses and monitors for 45 seconds.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.1150. Distribution of dry chemical.

46 C.F.R. § 154.1150

(a)
All locations on the above deck cargo area and the cargo piping outside that cargo area must be protected by:
(1)
At least two dry chemical hand hose lines; or
(2)
At least one dry chemical hand hose line and one dry chemical monitor.
(b)
At least one dry chemical storage unit and hand hose line or monitor must be at the after end of the cargo areas.
(c)
Each cargo loading and discharge manifold must be protected by at least one dry chemical monitor.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.1155. Hand hose line: Coverage.

46 C.F.R. § 154.1155

The coverage for the area for a hand hose line under § 154.1150 must not exceed the length of the hand hose line except the coverage for the protection of areas that are inaccessible to personnel must not exceed one-half the projection of the hose at its rated discharge, or 10 m (32.8 ft.), whichever is less.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.1160. Monitor coverage of system.

46 C.F.R. § 154.1160

The coverage of each dry chemical system monitor under § 154.1150 must not exceed:
(a)
10 m (32.8 ft.) at 10 kg/sec (22 lb/sec);
(b)
30 m (98.4 ft.) at 25 kg/sec (55 lb/sec);
(c)
40 m (131.2 ft.) at 45 kg/sec (99 lb/sec);
(d)
An interpolation between 10 m (32.8 ft.) at 10 kg/sec (22 lb/sec) and 30 m (98.4 ft.) at 25 kg/sec (55 lb/sec); or
(e)
An interpolation between 30 m (98.4 ft.) at 25 kg/sec (55 lb/sec) and 40 m (131.2 ft.) at 45 kg/sec (99 lb/sec).
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.1165. Controls.

46 C.F.R. § 154.1165

(a)
Each dry chemical hand hose line must be one that can be actuated at its hose reel or hose storage cabinet.
(b)
Each dry chemical monitor must be one that can be actuated and controlled at the monitor.
(c)
A dry chemical monitor for the cargo loading and discharging manifold areas must be one that can be:
(1)
Actuated from a location other than the monitor and manifold area; and
(2)
Except for pre-aimed monitors, controlled from a location other than the monitor and manifold area.
(d)
Each dry chemical storage unit must have independent piping with a stop valve in the piping for each remote hand hose line and remote monitor where the piping connects to the storage container, if the unit has:
(1)
More than one hand hose line;
(2)
More than one monitor; or
(3)
A combination of hand hose lines and monitors.
(e)
Each stop valve under paragraph (d) of the section must be capable of:
(1)
Manual operation; and
(2)
Being opened from the hose reel or monitor to which it is connected.
(f)
Damage to any dry chemical system hose, monitor, pipe or control circuits must not prevent the operation of other hoses, monitors, or control circuit that are connected to the same storage unit.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3703, 9101; Department of Homeland Security Delegation No. 0170.1.

Source

Source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.

§154.1170. Hand hose line: General.

46 C.F.R. § 154.1170

Each dry chemical hand hose line must:
(a)
Not be longer than 33m (108 ft.);
(b)
Be stored on a hose reel or in a hose cabinet and be one that is operable whether or not it is unwound from a hose reel or removed from a hose cabinet;
(c)
Be non-kinkable;
(d)
Have a nozzle with a valve to start and stop the flow of chemical;
(e)
Have a capacity of at least 3.5 kg/sec (7.7 lb./sec); and
(f)
Be one that can be operated by one person.