§111.107-1. Industrial systems.
46 C.F.R. § 111.107-1
For the purpose of this subpart, an industrial system is a system that—
Is not a ship's service load, as defined in § 110.15-1;
Is used only for the industrial function of the vessel;
Is not connected to the emergency power source; and
Does not have specific requirements addressed elsewhere in this subchapter.
An industrial system that meets the applicable requirements of NFPA 70 (incorporated by reference; see § 110.10-1 of this subchapter) must meet only the following:
Subpart 111.01 of this part—General.
Subpart 111.05 of this part—Equipment Ground, Ground Detection, and Grounded Systems.
Sections 111.12-1(b) and 111.12-1(c)—Prime movers.
Subpart 111.105 of this part—Hazardous Locations.
Cables that penetrate a watertight or fire boundary deck or bulkhead must—
Be installed in accordance with 46 CFR 111.60-5 and meet the flammability-test requirements of either IEEE 1202, IEC 60332-3-22:2018, or IEC 60332-3-21:2018, Category A or A F/R (all incorporated by reference; see § 110.10-1 of this subchapter); or
Be specialty cable installed in accordance with § 111.60-2.
Notes, amendments, and revision history
Amendments
[CGD 94-108, 61 FR 28286, June 4, 1996, as amended at 62 FR 23910, May 1, 1997; USCG-2003-16630, 73 FR 65201, Oct. 31, 2008; USCG-2020-0075, 88 FR 16368, Mar. 16, 2023]
Authority
Authority: 46 U.S.C. 3306, 3703; DHS Delegation No. 00170.1, Revision No. 01.2. Section 111.05-20 and Subpart 111.106 also issued under sec. 617, Pub. L. 111-281, 124 Stat. 2905.
Source
Source: CGD 74-125A, 47 FR 15236, Apr. 8, 1982, unless otherwise noted.
Amendments
[CGD 94-108, 61 FR 28286, June 4, 1996, as amended at 62 FR 23910, May 1, 1997; USCG-2003-16630, 73 FR 65201, Oct. 31, 2008; USCG-2020-0075, 88 FR 16368, Mar. 16, 2023]