§111.106-17. Piping: electrical bonding.

46 C.F.R. § 111.106-17

(a)
Tanks or piping systems that are separated from the hull structure by thermal isolation must be electrically bonded to the hull structure by a method under paragraph (c) of this section.
(b)
A pipe joint or a hose connection fitting that has a gasket must be electrically bonded by a method under paragraph (c) of this section that bonds—
(1)
Both sides of the connection to the hull structure; or
(2)
Each side of the connection to the other side.
(c)
An electrical bond must be made by at least one of the following methods:
(1)
A metal bonding strap attached by welding or bolting;
(2)
Two or more bolts that give metal-to-metal contact between the bolts and the parts to be bonded; or
(3)
Other metal-to-metal contact between adjacent parts under designed operating conditions.
Notes, amendments, and revision history

Source

Source: USCG-2012-0208, 79 FR 48930, Aug. 18, 2014, unless otherwise noted.

Authority

Authority: 46 U.S.C. 3306, 3703; DHS Delegation No. 00170.1, Revision No. 01.2. Section 111.05-20 and Subpart 111.106 also issued under sec. 617, Pub. L. 111-281, 124 Stat. 2905.

Source

Source: CGD 74-125A, 47 FR 15236, Apr. 8, 1982, unless otherwise noted.