§84.172. Airflow resistance test.

42 C.F.R. § 84.172

(a)
Resistance to airflow will be measured in the tight-fitting respiratory inlet covering of a complete particulate respirator mounted on a test fixture with air flowing at continuous rate of 85 ±2 liters per minute, before each test conducted in accordance with § 84.173.
(b)
Resistance of a complete tight-fitting powered air-purifying particulate respirator system will be measured with the blower off if the manufacturer indicates that the respirator should not be doffed in the event of a blower failure.
(c)
The maximum allowable resistance requirements for air-purifying particulate respirators are as follows: