  • (c) You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
    (1) Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
    (2) Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
    (3) Repairing defects according to the requirements in § 63.1047(d).
    (4) Recording the information specified in § 63.1048(a).
    (5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
    (6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.

Citations to §63.7913(c)(2)

  • (c) You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
    (1) Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
    (2) Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
    (3) Repairing defects according to the requirements in § 63.1047(d).
    (4) Recording the information specified in § 63.1048(a).
    (5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
    (6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.

Citations to §63.7913(c)(3)

  • (c) You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
    (1) Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
    (2) Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
    (3) Repairing defects according to the requirements in § 63.1047(d).
    (4) Recording the information specified in § 63.1048(a).
    (5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
    (6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.

Citations to §63.7913(c)(4)

  • (c) You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
    (1) Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
    (2) Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
    (3) Repairing defects according to the requirements in § 63.1047(d).
    (4) Recording the information specified in § 63.1048(a).
    (5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
    (6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.

Citations to §63.7913(c)(5)

  • (c) You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
    (1) Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
    (2) Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
    (3) Repairing defects according to the requirements in § 63.1047(d).
    (4) Recording the information specified in § 63.1048(a).
    (5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
    (6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.

Citations to §63.7913(c)(6)

  • (c) You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
    (1) Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
    (2) Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
    (3) Repairing defects according to the requirements in § 63.1047(d).
    (4) Recording the information specified in § 63.1048(a).
    (5) Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
    (6) Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.