US Codex
C.F.R.
Browse by date
Notes

40 C.F.R. §§ 63.7890–63.7922

27 sections in range

§63.7890. What emissions limitations and work practice standards must I meet for process vents?

40 C.F.R. § 63.7890

(a)
You must control HAP emissions from each new and existing process vent subject to § 63.7885(b)(1) according to emissions limitations and work practice standards in this section that apply to your affected process vents.
(b)
For your affected process vents, you must meet one of the facility-wide emission limit options specified in paragraphs (b)(1) through (4) of this section. If you have multiple affected process vent streams, you may comply with this paragraph using a combination of controlled and uncontrolled process vent streams that achieve the facility-wide emission limit that applies to you.
(1)
Reduce from all affected process vents the total emissions of the HAP listed in Table 1 of this subpart to a level less than 1.4 kilograms per hour (kg/hr) and 2.8 Mg/yr (3.0 pounds per hour (lb/hr) and 3.1 tpy); or
(2)
Reduce from all affected process vents the emissions of total organic compounds (TOC) (minus methane and ethane) to a level below 1.4 kg/hr and 2.8 Mg/yr (3.0 lb/hr and 3.1 tpy); or
(3)
Reduce from all affected process vents the total emissions of the HAP listed in Table 1 of this subpart by 95 percent by weight or more; or
(4)
Reduce from all affected process vents the emissions of TOC (minus methane and ethane) by 95 percent by weight or more.
(c)
For each closed vent system and control device you use to comply with paragraph (b) of this section, you must meet the operating limit requirements and work practice standards in § 63.7925(c) through (j) that apply to your closed vent system and control device.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006]

§63.7891. How do I demonstrate initial compliance with the emissions limitations and work practice standards for process vents?

40 C.F.R. § 63.7891

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7890(b) applicable to your affected process vents by meeting the requirements in paragraphs (b) through (d) of this section.
(b)
You have measured or determined using the procedures for performance tests and design evaluations in § 63.7941 that emission levels from all of your affected process vents meet the facility-wide emission limits in § 63.7890(b) that apply to you, as follows in paragraphs (b)(1) through (4) of this section.
(1)
If you elect to meet § 63.7890(b)(1), you demonstrate that the total emissions of the HAP listed in Table 1 of this subpart from all affected process vents at your facility are less than 1.4 kg/hr and 2.8 Mg/yr (3.0 lb/hr and 3.1 tpy).
(2)
If you elect to meet § 63.7890(b)(2), you demonstrate that emissions of TOC (minus methane and ethane) from all affected process vents at your facility are less than 1.4 kg/hr and 2.8 Mg/yr (3.0 lb/hr and 3.1 tpy).
(3)
If you elect to meet § 63.7890(b)(3), you demonstrate that the total emissions of the HAP listed in Table 1 of this subpart from all affected process vents are reduced by 95 percent by weight or more.
(4)
If you elect to meet § 63.7890(b)(4), you demonstrate that the emissions of TOC (minus methane and ethane) from all affected process vents are reduced by 95 percent by weight or more.
(c)
For each closed vent system and control device you use to comply with § 63.7890(b), you have met each requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
(d)
You have submitted a notification of compliance status according to the requirements in § 63.7950.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7892. What are my inspection and monitoring requirements for process vents?

40 C.F.R. § 63.7892

For each closed vent system and control device you use to comply with § 63.7890(b), you must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7893. How do I demonstrate continuous compliance with the emissions limitations and work practice standards for process vents?

40 C.F.R. § 63.7893

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7890 applicable to your affected process vents by meeting the requirements in paragraphs (b) through (d) of this section.
(b)
You must maintain emission levels from all of your affected process vents to meet the facilitywide emission limits in § 63.7890(b) that apply to you, as specified in paragraphs (b)(1) through (4) of this section.
(1)
If you elect to meet § 63.7890(b)(1), you maintain the total emissions of the HAP listed in Table 1 of this subpart from all affected process vents at your facility are less than 1.4 kg/hr and 2.8 Mg/yr (3.0 lb/hr and 3.1 tpy).
(2)
If you elect to meet § 63.7890(b)(2), you maintain emissions of TOC (minus methane and ethane) from all affected process vents at your facility are less than 1.4 kg/hr and 2.8 Mg/yr (3.0 lb/hr and 3.1 tpy).
(3)
If you elect to meet § 63.7890(b)(3), you maintain the total emissions of the HAP listed in Table 1 of this subpart from all affected process vents are reduced by 95 percent by weight or more.
(4)
If you elect to meet § 63.7890(b)(4), you maintain that the emissions of TOC (minus methane and ethane) from all affected process vents are reduced by 95 percent by weight or more.
(c)
For each closed vent system and control device you use to comply with § 63.7890(b), you have met each requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(d)
Keeping records to document continuous compliance with the requirements of this subpart according to the requirements in § 63.7952.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006]

§63.7895. What emissions limitations and work practice standards must I meet for tanks?

40 C.F.R. § 63.7895

(a)
You must control HAP emissions from each new and existing tank subject to § 63.7886(b)(1)(i) according to emissions limitations and work practice standards in this section that apply to your affected tanks.
(b)
For each affected tank, you must install and operate air pollution controls that meet the requirements in paragraphs (b)(1) through (4) of this section that apply to your tank.
(1)
Unless your tank is used for a waste stabilization process, as defined in § 63.7957, you must determine the maximum HAP vapor pressure (expressed in kilopascals (kPa)) of the remediation material placed in your tank using the procedures specified in § 63.7944.
(2)
If the maximum HAP vapor pressure of the remediation material you place in your tank is less than 76.6 kPa, then you must determine which tank level controls (i.e., Tank Level 1 or Tank Level 2) apply to your tank as shown in Table 2 of this subpart, and based on your tank's design capacity (expressed in cubic meters (m 3)) and the maximum HAP vapor pressure of the remediation material you place in this tank. If your tank is required by Table 2 of this subpart to use Tank Level 1 controls, then you must meet the requirements in paragraph (c) of this section. If your tank is required by Table 2 of this subpart to use Tank Level 2 controls, then you must meet the requirements in paragraph (d) of this section
(3)
If maximum HAP vapor pressure of the remediation material you place in your tank is 76.6 kPa or greater, then the tank must use one of the Tank Level 2 controls specified in paragraphs (d)(3) through (5) of this section. Use of floating roofs under paragraph (d)(1) or (2) of this section is not allowed for tanks managing these remediation materials.
(4)
A tank used for a waste stabilization process, as defined in § 63.7957, must use one of Tank Level 2 controls, as specified in paragraph (d) of this section, that is appropriate for your waste stabilization process.
(c)
If you use Tank Level 1 controls, you must install and operate a fixed roof according to the requirements in § 63.902, with the exceptions specified in paragraphs (c)(1) and (2) of this section. As an alternative to using this fixed roof, you may choose to use one of Tank Level 2 controls in paragraph (d) of this section.
(1)
Where § 63.902(c)(2) provides an exception for a spring-loaded pressure-vacuum relief valve, conservation vent, or similar type of pressure relief device which vents to the atmosphere, for any source for the purposes of this subpart, only a conservation vent is eligible for the exception after January 6, 2021. If your initial startup date is after September 3, 2019, the exception for a spring-loaded pressure-vacuum relief valve, conservation vent, or similar type of pressure relief device does not apply, with the exception of a conservation vent, for the purposes of this subpart after July 10, 2020.
(2)
The provisions of § 63.902(c)(3) do not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; for any source the provisions of § 63.902(c)(3) do not apply for the purposes of this subpart after January 6, 2021.
(d)
If you use Tank Level 2 controls, you must meet the requirements of one of the options in paragraphs (d)(1) through (5) of this section.
(1)
Install and operate a fixed roof with an internal floating roof according to the requirements in § 63.1063(a)(1)(i), (a)(2), and (b); or
(2)
Install and operate an external floating roof according to the requirements in § 63.1063(a)(1)(ii), (a)(2), and (b); or
(3)
Install and operate a fixed roof vented through a closed vent system to a control device according to the requirements in § 63.685(g). You must meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device; or
(4)
Install and operate a pressure tank according to the requirements in § 63.685(h); or
(5)
Locate the tank inside a permanent total enclosure and vent emissions from the enclosure through a closed vent system to a control device that is an enclosed combustion device according to the requirements in § 63.685(i). You must meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device.
(e)
As provided in § 63.6(g), you may request approval from the EPA to use an alternative to the work practice standards in this section that apply to your tanks. If you request for permission to use an alternative to the work practice standards, you must submit the information described in § 63.6(g)(2).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41703, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41703, July 10, 2020]

§63.7896. How do I demonstrate initial compliance with the emissions limitations and work practice standards for tanks?

40 C.F.R. § 63.7896

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7895 that apply to your affected tanks by meeting the requirements in paragraphs (b) through (h) of this section, as applicable to your containers.
(b)
You have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (b)(1) and (2) of this section.
(1)
You have determined the applicable tank control levels specified in § 63.7895(b) for the tanks to be used for your site remediation.
(2)
You have determined, according to the procedures in § 63.7944, and recorded the maximum HAP vapor pressure of the remediation material placed in each affected tank subject to § 63.7886(b)(1)(i) that does not use Tank Level 2 controls.
(c)
You must demonstrate initial compliance of each tank determined under paragraph (b) of this section to require Tank Level 1 controls if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (c)(1) through (3) of this section.
(1)
Each tank using Tank Level 1 controls is equipped with a fixed roof and closure devices according to the requirements in § 63.902(b) and (c), with the exceptions specified in § 63.7895(c)(1) and (2), and you have records documenting the design.
(2)
You have performed an initial visual inspection of the fixed roof and closure devices for defects according to the requirements in § 63.906(a) and you have records documenting the inspection results.
(3)
You will operate the fixed roof and closure devices according to the requirements in § 63.902, with the exceptions specified in § 63.7895(c)(1) and (2).
(d)
You must demonstrate initial compliance of each tank determined under paragraph (b) of this section to require Tank Level 2 controls and using a fixed roof with an internal floating roof according to § 63.7895(d)(1) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (d)(1) through (3) of this section.
(1)
Each tank is equipped with an internal floating roof that meets the requirements in § 63.1063(a) and you have records documenting the design.
(2)
You will operate the internal floating roof according to the requirements in § 63.1063(b).
(3)
You have performed an initial visual inspection according to the requirements in § 63.1063(d)(1) and you have a record of the inspection results.
(e)
You must demonstrate initial compliance of each tank determined under paragraph (b) of this section to require Tank Level 2 controls and using an external floating roof according to § 63.7895(d)(2) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (e)(1) through (3) of this section.
(1)
Each tank is equipped with an external floating roof that meets the requirements in § 63.1063(a) and you have records documenting the design.
(2)
You will operate the external floating roof according to the requirements in § 63.1063(b).
(3)
You have performed an initial seal gap measurement inspection according to the requirements in § 63.1063(d)(3) and you have records of the measurement results.
(f)
You must demonstrate initial compliance of each tank determined under paragraph (b) of this section to require Tank Level 2 controls and using a fixed roof vented to a control device according to § 63.7895(d)(3) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (f)(1) through (4) of this section.
(1)
Each tank is equipped with a fixed roof and closure devices according to the requirements in § 63.685(g), with the exceptions specified in § 63.7895(c)(1) and (2), and you have records documenting the design.
(2)
You have performed an initial visual inspection of fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3) and you have records documenting the inspection results.
(3)
You will operate the fixed roof and closure devices according to the requirements in § 63.685(g).
(4)
You have met each applicable requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
(g)
You must demonstrate initial compliance of each tank determined under paragraph (b) of this section to require Tank Level 2 controls and operates as a pressure tank according to § 63.7895(d)(4) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (g)(1) and (2) of this section.
(1)
Each tank is designed to operate as a pressure tank according to the requirements in § 63.685(h), and you have records documenting the design.
(2)
You will operate the pressure tank and according to the requirements in § 63.685(h).
(h)
You must demonstrate initial compliance of each tank determined under paragraph (b) of this section to require Tank Level 2 controls and using a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (h)(1) and (2) of this section.
(1)
You have submitted as part of your notification of compliance status a signed statement that you have performed the verification procedure according to the requirements in § 63.685(i), and you have records of the supporting calculations and measurements.
(2)
You have met each applicable requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006; 85 FR 41703, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006; 85 FR 41703, July 10, 2020]

§63.7897. What are my inspection and monitoring requirements for tanks?

40 C.F.R. § 63.7897

(a)
You must visually inspect each of your tanks using Tank Level 1 controls for defects at least annually according to the requirements in § 63.906(a).
(b)
You must inspect and monitor each of your tanks using Tank Level 2 controls according to the requirements in paragraphs (b)(1) through (5), as applicable to your tanks.
(1)
If you use a fixed roof with an internal floating roof according to § 63.7895(d)(1), you must visually inspect the fixed roof and internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
(2)
If you use an external floating roof according to § 63.7895(d)(2), you must visually inspect the external floating roof according to the requirements in § 63.1063(d)(1) and inspect the seals according to the requirements in § 63.1063(d)(2) and (3).
(3)
If you use a fixed roof vented to a control device according to § 63.7895(d)(3), you must meet requirements in paragraphs (b)(3)(i) and (ii) of this section.
(i)
You must visually inspect the fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3).
(ii)
You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
(4)
If you use a pressure tank according to § 63.7895(d)(4), you must visually inspect the tank and its closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h).
(5)
If you use a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5), you must meet requirements in paragraphs (b)(5)(i) and (ii) of this section.
(i)
You must perform the verification procedure for the permanent total enclosure at least annually according to the requirements in § 63.685(i).
(ii)
You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7898. How do I demonstrate continuous compliance with the emissions limitations and work practice standards for tanks?

40 C.F.R. § 63.7898

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7895 applicable to your affected tanks by meeting the requirements in paragraphs (b) through (d) of this section.
(b)
You must demonstrate continuous compliance with the requirement to determine the applicable tank control level specified in § 63.7895(b) for each affected tank by meeting the requirements in paragraphs (b)(1) through (3) of this section.
(1)
Keeping records of the tank design capacity according to the requirements in § 63.1065(a).
(2)
For tanks subject to § 63.7886(b)(1)(ii) and not using Tank Level 2 controls, meeting the requirements in paragraphs (b)(2)(i) and (ii) of this section.
(i)
Keeping records of the maximum HAP vapor pressure determined according to the procedures in § 63.7944 for the remediation material placed in each affected tank.
(ii)
Performing a new determination of the maximum HAP vapor pressure whenever changes to the remediation material managed in the tank could potentially cause the maximum HAP vapor pressure to increase to a level that is equal to or greater than the maximum HAP vapor pressure for the tank design capacity specified in Table 2. You must keep records of each determination.
(3)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(c)
You must demonstrate continuous compliance for each tank determined to require Tank Level 1 controls by meeting the requirements in paragraphs (c)(1) through (5) of this section.
(1)
Operating and maintaining the fixed roof and closure devices according to the requirements in § 63.902(c), with the exceptions specified in § 63.7895(c)(1) and (2).
(2)
Visually inspecting the fixed roof and closure devices for defects at least annually according to the requirements in § 63.906(a).
(3)
Repairing defects according to the requirements in § 63.63.906(b).
(4)
Recording the information specified in § 63.907(a)(3) and (b).
(5)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(d)
You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a fixed roof with an internal floating roof according to § 63.7895(d)(1) by meeting the requirements in paragraphs (d)(1) through (5) of this section.
(1)
Operating and maintaining the internal floating roof according to the requirements in § 63.1063(b).
(2)
Visually inspecting the internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
(3)
Repairing defects according to the requirements in § 63.1063(e).
(4)
Recording the information specified in § 63.1065(b) through (d).
(5)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(e)
You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using an external floating roof according to § 63.7895(d)(2) by meeting the requirements in paragraphs (e)(1) through (5) of this section.
(1)
Operating and maintaining the external floating roof according to the requirements in § 63.1063(b).
(2)
Visually inspecting the external floating roof according to the requirements in § 63.1063(d)(1) and inspecting the seals according to the requirements in § 63.1063(d)(2) and (3).
(3)
Repairing defects according to the requirements in § 63.1063(e).
(4)
Recording the information specified in § 63.1065(b) through (d).
(5)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(f)
You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a fixed roof vented to a control device according to § 63.7895(d)(3) by meeting the requirements in paragraphs (f)(1) through (6) of this section.
(1)
Operating and maintaining the fixed roof and closure devices according to the requirements in § 63.685(g).
(2)
Visually inspecting the fixed roof and closure devices for defects at least annually according to the requirements in § 63.695(b)(3)(i).
(3)
Repairing defects according to the requirements in § 63.695(b)(4).
(4)
Recording the information specified in § 63.696(e).
(5)
Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(6)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(g)
You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and operated as a pressure tank according to § 63.7895(d)(4) by meeting the requirements in paragraphs (g)(1) through (3) of this section.
(1)
Operating and maintaining the pressure tank and closure devices according to the requirements in § 63.685(h).
(2)
Visually inspecting each pressurized tank and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h), and recording the results of each inspection.
(3)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(h)
You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5) by meeting the requirements in paragraphs (h)(1) through (4) of this section.
(1)
Performing the verification procedure for the enclosure annually according to the requirements in § 63.685(i).
(2)
Recording the information specified in § 63.696(f).
(3)
Meeting each applicable requirement for demonstrating continuous compliance with the emissions limitations and work practice standards for a closed vent system and control device in § 63.7928.
(4)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006; 85 FR 41703, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006; 85 FR 41703, July 10, 2020]

§63.7900. What emissions limitations and work practice standards must I meet for containers?

40 C.F.R. § 63.7900

(a)
You must control HAP emissions from each new and existing container subject to § 63.7886(b)(1)(ii) according to emissions limitations and work practice standards in this section that apply to your affected containers.
(b)
For each container having a design capacity greater than 0.1 m 3 you must meet the requirements in paragraph (b)(1) or (2) of this section that apply to your container except at the times the container is used for treatment of remediation material by a waste stabilization process, as defined in § 63.7957. As an alternative for any container subject to this paragraph, you may choose to meet the requirements in paragraph (d) of this section.
(1)
If the design capacity of your container is less than or equal to 0.46 m 3, then you must use controls according to the standards for Container Level 1 controls as specified in § 63.922. As an alternative, you may choose to use controls according to either of the standards for Container Level 2 controls as specified in § 63.923. § 63.922(d)(4) and (5) do not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.922(d)(4) and (5) do not apply for the purposes of this subpart for any source after January 6, 2021.
(2)
If the design capacity of your container is greater than 0.46 m3, then you must use controls according to the standards for Container Level 2 controls as specified in § 63.923 except as provided for in paragraph (b)(3) of this section. § 63.923(d)(4) and (5) do not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.923(d)(4) and (5) do not apply for the purposes of this subpart for any source after January 6, 2021.
(3)
As an alternative to meeting the standards in paragraph (b)(2) of this section for containers with a capacity greater than 0.46 m3, if you determine that either of the conditions in paragraph (b)(3)(i) or (ii) apply to the remediation material placed in your container, then you may use controls according to the standards for Container Level 1 controls as specified in § 63.922. § 63.922(d)(4) and (5) do not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.922(d)(4) and (5) do not apply for the purposes of this subpart for any source after January 6, 2021.
(c)
At times when a container having a design capacity greater than 0.1 m3 is used for treatment of a remediation material by a waste stabilization process as defined in § 63.7957, you must control air emissions from the container during the process whenever the remediation material in the container is exposed to the atmosphere according to the standards for Container Level 3 controls as specified in § 63.924. You must meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device. § 63.924(d) does not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.924(d) does not apply for the purposes of this subpart for any source after January 6, 2021.
(d)
As an alternative to meeting the requirements in paragraph (b) of this section, you may choose to use controls on your container according to the standards for Container Level 3 controls as specified in § 63.924. You must meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device. § 63.924(d) does not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.924(d) does not apply for the purposes of this subpart for any source after January 6, 2021.
(e)
As provided in § 63.6(g), you may request approval from the EPA to use an alternative to the work practice standards in this section that apply to your containers. If you request for permission to use an alternative to the work practice standards, you must submit the information described in § 63.6(g)(2).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41703, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41703, July 10, 2020]

§63.7901. How do I demonstrate initial compliance with the emissions limitations and work practice standards for containers?

40 C.F.R. § 63.7901

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7900 that apply to your affected containers by meeting the requirements in paragraphs (b) through (e) of this section, as applicable to your containers.
(b)
You have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (b)(1) and (2) of this section.
(1)
You have determined the applicable container control levels specified in § 63.7900 for the containers to be used for your Site Remediation.
(2)
You have determined and recorded the maximum vapor pressure or total organic concentration for the remediation material placed in containers with a design capacity greater than 0.46 m 3, and do not use Container Level 2 or Level 3 controls.
(c)
You must demonstrate initial compliance of each container determined under paragraph (b) of this section to require Container Level 1 controls if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (c)(1) and (2) of this section.
(1)
Each container using Container Level 1 controls will be one of the containers specified in § 63.922(b).
(2)
You will operate each container cover and closure device according to the requirements in § 63.922(d), with the exceptions specified in § 63.7900(b)(1).
(d)
You must demonstrate initial compliance of each container determined under paragraph (b) of this section to require Container Level 2 controls if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (d)(1) through (4) of this section.
(1)
Each container using Container Level 2 controls will be one of the containers specified in § 63.923(b).
(2)
You will transfer remediation materials into and out of each container according to the procedures in § 63.923(d).
(3)
You will operate and maintain the container covers and closure devices according to the requirements in § 63.923(d), with the exceptions specified in § 63.7900(b)(2).
(4)
You have records that the container meets the applicable U.S. Department of Transportation regulations, or you have conducted an initial test of each container for no detectable organic emissions using the procedures in § 63.925(a), and have records documenting the test results, or you have demonstrated within the last 12 months that each container is vapor-tight according to the procedures in § 63.925(a) and have records documenting the test results.
(e)
You must demonstrate initial compliance of each container determined under paragraph (b) of this section to require Container Level 3 controls if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (e)(1) and (2) of this section.
(1)
For each permanent total enclosure you use to comply with § 63.7900, you have performed the verification procedure according to the requirements in § 63.924(c)(1), and prepare records of the supporting calculations and measurements.
(2)
You have met each applicable requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

§63.7902. What are my inspection and monitoring requirements for containers?

40 C.F.R. § 63.7902

(a)
You must inspect each container using Container Level 1 or Container Level 2 controls according to the requirements in § 63.926(a).
(b)
If you use Container Level 3 controls, you must meet requirements in paragraphs (b)(1) and (2) of this section, as applicable to your site remediation.
(1)
You must perform the verification procedure for each permanent total enclosure annually according to the requirements in § 63.924(c)(1).
(2)
You must monitor and inspect each closed vent system and control device according to the requirements in § 63.7927 that apply to you.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7903. How do I demonstrate continuous compliance with the emissions limitations and work practice standards for containers?

40 C.F.R. § 63.7903

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7900 applicable to your affected containers by meeting the requirements in paragraphs (b) through (e) of this section.
(b)
You must demonstrate continuous compliance with the requirement to determine the applicable container control level specified in § 63.7900(b) for each affected tank by meeting the requirements in paragraphs (b)(1) through (3) of this section.
(1)
Keeping records of the quantity and design capacity for each type of container used for your site remediation and subject to § 63.7886(b)(1)(ii).
(2)
For containers subject to § 63.7886(b)(1)(ii) with a design capacity greater than 0.46 m 3 and not using Container Level 2 or Container Level 3 controls, meeting the requirements in paragraphs (b)(2)(i) and (ii) of this section.
(i)
Keeping records of the maximum vapor pressure or total organic concentration for the remediation material placed in the containers, as applicable to the conditions in § 63.7900(b)(3)(i) or (ii) for which your containers qualify to use Container Level 1 controls.
(ii)
Performing a new determination whenever changes to the remediation material placed in the containers could potentially cause the maximum vapor pressure or total organic concentration to increase to a level that is equal to or greater than the conditions specified in § 63.7900(b)(3)(i) or (ii), as applicable to your containers. You must keep records of each determination.
(3)
Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
(c)
You must demonstrate continuous compliance for each container determined to require Container Level 1 controls by meeting the requirements in paragraphs (c)(1) through (5) of this section.
(1)
Operating and maintaining covers for each container according to the requirements in § 63.922(d), with the exceptions specified in § 63.7900(b)(1).
(2)
Inspecting each container annually according to the requirements in § 63.926(a)(2).
(3)
Emptying or repairing each container according to the requirements in § 63.926(a)(3).
(4)
Keeping records of an inspection that includes the information in paragraphs (a)(4)(i) and (ii) of this section.
(i)
Date of each inspection; and
(ii)
If a defect is detected during an inspection, the location of the defect, a description of the defect, the date of detection, the corrective action taken to repair the defect, and if repair is delayed, the reason for any delay and the date completion of the repair is expected.
(5)
Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
(d)
You must demonstrate continuous compliance for each container determined to require Container Level 2 controls by meeting the requirements in paragraphs (d)(1) through (6) of this section.
(1)
Transferring remediation material in and out of the container according to the requirements in § 63.923(c).
(2)
Operating and maintaining container covers according to the requirements in § 63.923(d), with the exceptions specified in § 63.7900(b)(2).
(3)
Inspecting each container annually according to the requirements in § 63.926(a)(2).
(4)
Emptying or repairing containers according to the requirements in § 63.926(a)(3).
(5)
Keeping records of each inspection that include the information in paragraphs (d)(5)(i) and (ii) of this section.
(i)
Date of each inspection; and
(ii)
If a defect is detected during an inspection, the location of the defect, a description of the defect, the date of detection, the corrective action taken to repair the defect, and if repair is delayed, the reason for any delay and the date completion of the repair is expected.
(6)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(e)
You must demonstrate continuous compliance for each container determined to require Container Level 3 controls by meeting the requirements in paragraphs (e)(1) through (4) of this section.
(1)
Performing the verification procedure for the enclosure annually according to the requirements in § 63.685(i).
(2)
Recording the information specified in § 63.696(f).
(3)
Meeting each applicable requirement for demonstrating continuous compliance with the emissions limitations and work practice standards for a closed vent system and control device in § 63.7928.
(4)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

§63.7905. What emissions limitations or work practice standards must I meet for surface impoundments?

40 C.F.R. § 63.7905

(a)
You must control HAP emissions from each new and existing surface impoundment subject to § 63.7886(b)(1)(iii) according to emissions limitations and work practice standards in this section that apply to your affected surface impoundments.
(b)
For each affected surface impoundment, you must install and operate air pollution controls that meet either of the options in paragraphs (b)(1) or (2) of this section.
(1)
Install and operate a floating membrane cover according to the requirements in § 63.942. § 63.942(c)(2) and (3) do not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.942(c)(2) and (3) do not apply for the purposes of this subpart for any source after January 6, 2021; or
(2)
Install and operate a cover vented through a closed vent system to a control device according to the requirements in § 63.943. You must meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device. § 63.943(c)(2) does not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.943(c)(2) does not apply for the purposes of this subpart for any source after January 6, 2021.
(c)
As provided in § 63.6(g), you may request approval from the EPA to use an alternative to the work practice standards in this section that apply to your surface impoundments. If you request for permission to use an alternative to the work practice standards, you must submit the information described in § 63.6(g)(2).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

§63.7906. How do I demonstrate initial compliance with the emissions limitations or work practice standards for surface impoundments?

40 C.F.R. § 63.7906

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7905 that apply to your affected surface impoundments by meeting the requirements in paragraphs (b) and (c) of this section, as applicable to your surface impoundments.
(b)
You must demonstrate initial compliance of each surface impoundment using a floating membrane cover according to § 63.7905(b)(1) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (b)(1) through (3) of this section.
(1)
You have installed a floating membrane cover and closure devices that meet the requirements in § 63.942(b), and you have records documenting the design and installation.
(2)
You will operate the cover and closure devices according to the requirements in § 63.942(c), with the exceptions specified in § 63.7905(b)(1).
(3)
You have performed an initial visual inspection of each surface impoundment and closure devices according to the requirements in § 63.946(a), and you have records documenting the inspection results.
(c)
You must demonstrate initial compliance of each surface impoundment using a cover vented to a control device according to § 63.7905(b)(2) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (c)(1) through (4) of this section.
(1)
You have installed a cover and closure devices that meet the requirements in § 63.943(b), and have records documenting the design and installation.
(2)
You will operate the cover and closure devices according to the requirements in § 63.943(c), with the exceptions specified in § 63.7905(b)(2).
(3)
You have performed an initial visual inspection of each cover and closure devices according to the requirements in § 63.946(b), and have records documenting the inspection results.
(4)
You have met each applicable requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

§63.7907. What are my inspection and monitoring requirements for surface impoundments?

40 C.F.R. § 63.7907

(a)
If you use a floating membrane cover according to § 63.7905(b)(1), you must visually inspect the floating membrane cover and its closure devices at least annually according to the requirements in § 63.946(a).
(b)
If you use a cover vented to a control device according to § 63.7905(b)(2), you must meet requirements in paragraphs (b)(1) and (2) of this section.
(1)
You must visually inspect the cover and its closure devices for defects according to the requirements in § 63.946(b).
(2)
You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7908. How do I demonstrate continuous compliance with the emissions limitations and work practice standards for surface impoundments?

40 C.F.R. § 63.7908

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7905 applicable to your affected surface impoundments by meeting the requirements in paragraphs (b) and (c) of this section as applicable to your surface impoundments.
(b)
You must demonstrate continuous compliance for each surface impoundment using a floating membrane cover according to § 63.7905(b)(1) by meeting the requirements in paragraphs (b)(1) through (5) of this section.
(1)
Operating and maintaining the floating membrane cover and closure devices according to the requirements in § 63.942(c), with the exceptions specified in § 63.7905(b)(1).
(2)
Visually inspecting the floating membrane cover and closure devices for defects at least annually according to the requirements in § 63.946(a).
(3)
Repairing defects according to the requirements in § 63.946(c).
(4)
Recording the information specified in § 63.947(a)(2) and (a)(3).
(5)
Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
(c)
You must demonstrate continuous compliance for each surface impoundment using a cover vented to a control device according to § 63.7905(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
(1)
Operating and maintaining the floating membrane cover and closure devices according to the requirements in § 63.943(c), with the exceptions specified in § 63.7905(b)(2).
(2)
Visually inspecting the cover and its closure devices for defects at least annually according to the requirements in § 63.946(b).
(3)
Repairing defects according to the requirements in § 63.946(c).
(4)
Recording the information specified in § 63.947(a)(2) and (a)(3).
(5)
Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(6)
Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41704, July 10, 2020]

§63.7910. What emissions limitations and work practice standards must I meet for separators?

40 C.F.R. § 63.7910

(a)
You must control HAP emissions from each new and existing oil-water separator and organic-water separator subject to § 63.7886(b)(1)(iv) according to emissions limitations and work practice standards in this section that apply to your affected separators.
(b)
For each affected separator, you must install and operate air pollution controls that meet one of the options in paragraphs (b)(1) through (3) of this section.
(1)
Install and operate a floating roof according to the requirements in § 63.1043. For portions of the separator where it is infeasible to install and operate a floating roof, such as over a weir mechanism, you must comply with the requirements specified in paragraph (b)(2) of this section. § 63.1043(c)(2) does not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.1043(c)(2) does not apply for the purposes of this subpart for any source after January 6, 2021.
(2)
Install and operate a fixed roof vented through a closed vent system to a control device according to the requirements in § 63.1044. You must meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device. § 63.1044(c)(2) does not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.1044(c)(2) does not apply for the purposes of this subpart for any source after January 6, 2021.
(3)
Install and operate a pressurized separator according to the requirements in § 63.1045. § 63.1045(b)(3)(i) does not apply for the purposes of this subpart if your initial startup date is after September 3, 2019; § 63.1045(b)(3)(i) does not apply for the purposes of this subpart for any source after January 6, 2021.
(c)
As provided in § 63.6(g), you may request approval from the EPA to use an alternative to the work practice standards in this section that apply to your separators. If you request for permission to use an alternative to the work practice standards, you must submit the information described in § 63.6(g)(2).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

§63.7911. How do I demonstrate initial compliance with the emissions limitations and work practice standards for separators?

40 C.F.R. § 63.7911

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7910 that apply to your affected separators by meeting the requirements in paragraphs (b) through (d) of this section, as applicable to your separators.
(b)
You must demonstrate initial compliance of each separator using a floating roof according to § 63.7910(b)(1) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (b)(1) through (4) of this section.
(1)
You have installed a floating roof and closure devices that meet the requirements in § 63.1043(b), and you have records documenting the design and installation.
(2)
You will operate the floating roof and closure devices according to the requirements in § 63.1043(c), with the exceptions specified in § 63.7910(b)(1).
(3)
You have performed an initial seal gap measurement inspection using the procedures in § 63.1046(b), and you have records documenting the measurement results.
(4)
You have performed an initial visual inspection of the floating roof and closure devices for defects according to the requirements in § 63.1047(b)(2), and you have records documenting the inspection results.
(5)
For any portions of the separator using a fixed roof vented to a control device according to § 63.7910(b)(1), you have met the requirements in paragraphs (c)(1) through (4) of this section.
(c)
You must demonstrate initial compliance of each separator using a fixed roof vented to a control device according to § 63.7910(b)(2) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (c)(1) through (4) of this section.
(1)
You have installed a fixed roof and closure devices that meet the requirements in § 63.1042(b), and you have records documenting the design and installation.
(2)
You will operate the fixed roof and its closure devices according to the requirements in § 63.1042(c). § 63.1042(c)(3) does not apply for the purposes of this subpart if your initial date is after September 3, 2019; § 63.1042(c)(3) does not apply for the purposes of this subpart for any source after January 6, 2021.
(3)
You have performed an initial visual inspection of the fixed roof and closure devices for defects according to the requirements in § 63.1047(a).
(4)
You have met each applicable requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
(d)
You must demonstrate initial compliance of each pressurized separator that operates as a closed system according to § 63.7910(b)(3) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (d)(1) and (2) of this section.
(1)
You have installed a pressurized separator that operates as a closed system according to the requirements in § 63.1045(b)(1) and (b)(2), and you have records of the design and installation.
(2)
You will operate the pressurized separator as a closed system according to the requirements in § 63.1045(b)(3), with the exceptions specified in § 63.7910(b)(3).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

§63.7912. What are my inspection and monitoring requirements for separators?

40 C.F.R. § 63.7912

(a)
If you use a floating roof according to § 63.7910(b)(1), you must meet requirements in paragraphs (a)(1) and (2) of this section.
(1)
Measure the seal gaps at least annually according to the requirements in § 63.1047(b)(1).
(2)
Visually inspect the floating roof at least annually according to the requirements in § 63.1047(b)(2).
(b)
If you use a cover vented to a control device according to § 63.7910(b)(1) or (2), you must meet requirements in paragraphs (b)(1) and (2) of this section.
(1)
You must visually inspect the cover and its closure devices for defects according to the requirements in § 63.1047(c).
(2)
You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
(c)
If you use a pressurized separator that operates as a closed system according to § 63.7910(b)(3), you must visually inspect each pressurized separator and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.1045(b), with the exceptions specified in § 63.7910(b)(3).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

§63.7913. How do I demonstrate continuous compliance with the emissions limitations and work practice standards for separators?

40 C.F.R. § 63.7913

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7910 applicable to your affected separators by meeting the requirements in paragraphs (b) through (d) of this section as applicable to your surface impoundments.
(b)
You must demonstrate continuous compliance for each separator using a floating roof according to § 63.7910(b)(1) by meeting the requirements in paragraphs (b)(1) through (6) of this section.
(1)
Operating and maintaining the floating roof according to the requirements in § 63.1043(b).
(2)
Performing seal gap measurement inspections at least annually according to the requirements in § 63.1047(b)(1).
(3)
Visually inspecting the floating roof at least annually according to the requirements in § 63.1047(b)(2).
(4)
Repairing defects according to the requirements in § 63.1047(d).
(5)
Recording the information specified in § 63.1048(a) and (b).
(6)
Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
(c)
You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
(1)
Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
(2)
Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
(3)
Repairing defects according to the requirements in § 63.1047(d).
(4)
Recording the information specified in § 63.1048(a).
(5)
Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(6)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(d)
You must demonstrate continuous compliance for each pressurized separator operated as a closed system according to § 63.7910(b)(3) by meeting the requirements in paragraphs (d)(1) and (2) of this section.
(1)
Operating the pressurized separator at all times according to the requirements in § 63.1045, with the exceptions specified in § 63.7910(b)(3).
(2)
Visually inspecting each pressurized tank and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.1045(b), and recording the results of each inspection.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006; 85 FR 41705, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69017, Nov. 29, 2006; 85 FR 41705, July 10, 2020]

§63.7915. What emissions limitations and work practice standards must I meet for transfer systems?

40 C.F.R. § 63.7915

(a)
You must control HAP emissions from each new and existing transfer system subject to § 63.7886(b)(1)(v) according to emissions limitations and work practice standards in this section that apply to your affected transfer systems.
(b)
For each affected transfer system that is an individual drain system as defined in § 63.7957, you must install and operate controls according to the requirements in § 63.962.
(c)
For each affected transfer system that is not an individual drain system as defined in § 63.7957, you must use one of the transfer systems specified in paragraphs (c)(1) through (3) of this section.
(1)
A transfer system that uses covers according to the requirements in § 63.689(d).
(2)
A transfer system that consists of continuous hard piping. All joints or seams between the pipe sections must be permanently or semi-permanently sealed (e.g., a welded joint between two sections of metal pipe or a bolted and gasketed flange).
(3)
A transfer system that is enclosed and vented through a closed vent system to a control device according to the requirements specified in paragraphs (c)(3)(i) and (ii) of this section.
(i)
The transfer system is designed and operated such that an internal pressure in the vapor headspace in the enclosure is maintained at a level less than atmospheric pressure when the control device is operating, and
(ii)
The closed vent system and control device are designed and operated to meet the emissions limitations and work practice standards in § 63.7925 that apply to your closed vent system and control device.
(d)
As provided in § 63.6(g), you may request approval from the EPA to use an alternative to the work practice standards in this section that apply to your transfer systems. If you request for permission to use an alternative to the work practice standards, you must submit the information described in § 63.6(g)(2).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]

§63.7916. How do I demonstrate initial compliance with the emissions limitations and work practice standards for transfer systems?

40 C.F.R. § 63.7916

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7915 that apply to your affected transfer systems by meeting the requirements in paragraphs (b) through (e) of this section, as applicable to your transfer systems.
(b)
You must demonstrate initial compliance of each individual drain system using controls according to § 63.7915(b) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (b)(1) through (3) of this section.
(1)
You have installed air emission controls for each individual drain system and junction box according to the requirements in § 63.962(a) and (b), and you have records documenting the installation and design.
(2)
You will operate the air emission controls according to the requirements in § 63.962(b)(5).
(3)
You have performed an initial visual inspection of each individual drain system according to the requirements in § 63.964(a), and you have records documenting the inspection results.
(c)
You must demonstrate initial compliance of each transfer system using covers according to § 63.7915(c)(1) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (c)(1) through (3) of this section.
(1)
Each transfer system is equipped with covers and closure devices according to the requirements in § 63.689(d)(1) through (4), and you have records documenting the design and installation.
(2)
You have performed an initial inspection of each cover and its closure devices for defects according to the requirements in § 63.695(d)(1) through (5), and you have records documenting the inspection results.
(3)
You will operate each cover and its closure devices according to the requirements in § 63.689(5).
(d)
You must demonstrate initial compliance of each transfer system that consists of hard piping according to § 63.7915(c)(2) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (d)(1) and (2) of this section.
(1)
You have installed a transfer system that consists entirely of hard piping and meets the requirements in § 63.7915(c)(2), and you have records documenting the design and installation.
(2)
You have performed an initial inspection of the entire transfer system to verify that all joints or seams between the pipe sections are permanently or semi-permanently sealed (e.g., a welded joint between two sections of metal pipe or a bolted and gasketed flange), and you have records documenting the inspection results.
(e)
You must demonstrate initial compliance of each transfer system that is enclosed and vented to a control device according to § 63.7915(e)(3) if you have submitted as part of your notification of compliance status, specified in § 63.7950, a signed statement that you have met the requirements in paragraphs (e)(1) and (2) of this section.
(1)
You have installed a transfer system that is designed and operated such that an internal pressure in the vapor headspace in the enclosure is maintained at a level less than atmospheric pressure when the control device is operating, and you have records documenting the design and installation.
(2)
You have met each applicable requirement for demonstrating initial compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7926.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7917. What are my inspection and monitoring requirements for transfer systems?

40 C.F.R. § 63.7917

(a)
If you operate an individual drain system as a transfer system according to § 63.7915(b), you must visually inspect each individual drain system at least annually according to the requirements in § 63.964(a).
(b)
If you operate a transfer system using covers according to § 63.7915(c)(1), you must inspect each cover and its closure devices for defects according to the requirements in § 63.695(d)(1) through (5).
(c)
If you operate a transfer system consisting of hard piping according to § 63.7915(c)(2), you must annually inspect the unburied portion of pipeline and all joints for leaks and other defects. In the event that a defect is detected, you must repair the leak or defect according to the requirements of paragraph (e) of this section.
(d)
If you operate a transfer system that is enclosed and vented to a control device according to § 63.7915(c)(3), you must meet requirements in paragraphs (d)(1) and (2) of this section.
(1)
You must annually inspect all enclosure components (e.g., enclosure sections, closure devices, fans) for defects that would prevent an internal pressure in the vapor headspace in the enclosure from continuously being maintained at a level less than atmospheric pressure when the control device is operating. In the event that a defect is detected, you must repair the defect according to the requirements of paragraph (e) of this section.
(2)
You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
(e)
If you are subject to paragraph (c) or (d) of this section, you must repair all detected defects as specified in paragraphs (e)(1) through (3) of this section.
(1)
You must make first efforts at repair of the defect no later than 5 calendar days after detection and repair shall be completed as soon as possible but no later than 45 calendar days after detection except as provided in paragraph (e)(2) of this section.
(2)
Repair of a defect may be delayed beyond 45 calendar days if you determine that repair of the defect requires emptying or temporary removal from service of the transfer system and no alternative transfer system is available at the site to accept the material normally handled by the system. In this case, you must repair the defect the next time the process or unit that is generating the material handled by the transfer system stops operation. Repair of the defect must be completed before the process or unit resumes operation.
(3)
You must maintain a record of the defect repair according to the requirements specified in § 63.7952.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]

§63.7918. How do I demonstrate continuous compliance with the emissions limitations and work practice standards for transfer systems?

40 C.F.R. § 63.7918

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7915 applicable to your affected transfer system by meeting the requirements in paragraphs (b) through (e) of this section as applicable to your transfer systems.
(b)
You must demonstrate continuous compliance for each individual drain system using controls according to § 63.7915(b) by meeting the requirements in paragraphs (b)(1) through (5) of this section.
(1)
Operating and maintaining the air emission controls for individual drain systems according to the requirements in § 63.962.
(2)
Visually inspecting each individual drain system at least annually according to the requirements in § 63.964(a).
(3)
Repairing defects according to the requirements in § 63.964(b).
(4)
Recording the information specified in § 63.965(a).
(5)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(c)
You must demonstrate continuous compliance for each transfer system using covers according to § 63.7915(c)(1) by meeting the requirements in paragraphs (c)(1) through (4) of this section.
(1)
Operating and maintaining each cover and its closure devices according to the requirements in § 63.689(d)(1) through (5).
(2)
Performing inspections of each cover and its closure devices for defects at least annually according to the requirements in § 63.695(d)(1) through (5).
(3)
Repairing defects according to the requirements in § 63.695(5)
(4)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(d)
You must demonstrate continuous compliance for each transfer system that consists of hard piping according to § 63.7915(c)(2) by meeting the requirements in paragraphs (d)(1) through (4) of this section.
(1)
Operating and maintaining the pipeline to ensure that all joints or seams between the pipe sections remain permanently or semi-permanently sealed (e.g., a welded joint between two sections of metal pipe or a bolted and gasketed flange).
(2)
Inspecting the pipeline for defects at least annually according to the requirements in § 63.7917(c).
(3)
Repairing defects according to the requirements in § 63.7917(e).
(4)
Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
(e)
You must demonstrate continuous compliance for each transfer system that is enclosed and vented to a control device according to § 63.7915(c)(3) by meeting the requirements in paragraphs (e)(1) through (5) of this section.
(1)
Operating and maintaining the enclosure to ensure that the internal pressure in the vapor headspace in the enclosure is maintained continuously at a level less than atmospheric pressure when the control device is operating.
(2)
Inspecting the enclosure and its closure devices for defects at least annually according to the requirements in § 63.7918(d).
(3)
Repairing defects according to the requirements in § 63.7918(e).
(4)
Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
(5)
Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 71 FR 69018, Nov. 29, 2006]

§63.7920. What emissions limitations and work practice standards must I meet for equipment leaks?

40 C.F.R. § 63.7920

(a)
You must control HAP emissions from each new and existing equipment subject to § 63.7887 according to emissions limitations and work practice standards in this section that apply to your affected equipment.
(b)
For your affected equipment, you must meet the requirements in either paragraph (b)(1) or (2) of this section.
(1)
Control equipment leaks according to all applicable requirements under 40 CFR part 63, subpart TT— National Emission Standards for Equipment Leaks—Control Level 1, with the differences noted in paragraph (b)(3) of this section for the purposes of this subpart; or
(2)
Control equipment leaks according to all applicable requirements under 40 CFR part 63, subpart UU— National Emission Standards for Equipment Leaks—Control Level 2.
(3)
(i)
For the purpose of complying with the requirements of § 63.1006(b)(2), the instrument reading that defines a leak is 500 parts per million or greater.
(ii)
For the purpose of complying with the requirements of § 63.1007(b)(2), the instrument reading that defines a leak is 5,000 parts per million or greater for pumps handling polymerizing monomers; 2,000 parts per million or greater for pumps in food/medical service; and 1,000 parts per million or greater for all other pumps.
(c)
If you use a closed vent system and control device to comply with this section, as an alternative to meeting the standards in § 63.1015 or § 63.1034 for closed vent systems and control devices, you may elect to meet the requirements in §§ 63.7925 through 63.7928 that apply to your closed vent system and control device.
(d)
For the purposes of this subpart, the requirements of § 63.7920(e) of this subpart apply rather than those of § 63.1030 or of § 63.1011, as applicable, for pressure relief devices in gas and vapor service. The requirements of § 63.7920(e) of this subpart apply rather than those of § 63.1029 or of § 63.1010, as applicable, for pressure relief devices in liquid service.
(e)
Operate each pressure relief device under normal operating conditions, as indicated by an instrument reading of less than 500 ppm above the background level as detected by the method specified in § 63.1004(b) or § 63.1023(b), as applicable.
(f)
As provided in § 63.6(g), you may request approval from the EPA to use an alternative to the work practice standards in this section that apply to your equipment. If you request for permission to use an alternative to the work practice standards, you must submit the information described in § 63.6(g)(2).
Notes, amendments, and revision history

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[68 FR 58190, Oct. 8, 2003, as amended at 85 FR 41705, July 10, 2020]

§63.7921. How do I demonstrate initial compliance with the emissions limitations and work practice standards for equipment leaks?

40 C.F.R. § 63.7921

(a)
You must demonstrate initial compliance with the emissions limitations and work practice standards in § 63.7920 that apply to your affected equipment by meeting the requirements in paragraphs (b) and (c) of this section, as applicable to your affected sources.
(b)
If you control equipment leaks according to the requirements under § 63.7920(b)(1), you must demonstrate initial compliance if you have met the requirements in paragraphs (b)(1) and (2) of this section.
(1)
You include the information required in § 63.1018(a)(1) in your notification of compliance status report.
(2)
You have submitted as part of your notification of compliance status a signed statement that—
(i)
You will meet the requirements in §§ 63.1002 through 63.1016 that apply to your affected equipment.
(ii)
You have identified the equipment subject to control according to the requirements in § 63.1003, including equipment designated as unsafe to monitor, and have records supporting the determinations with a written plan for monitoring the equipment according to the requirements in § 63.1003(c)(4).
(c)
If you control equipment leaks according to the requirements under § 63.7920(b)(2), you must demonstrate initial compliance if you have met the requirements in paragraphs (c)(1) and (2) of this section.
(1)
You have included the information required in § 63.1039(a) in your notification of compliance status report.
(2)
You have submitted as part of your notification of compliance status a signed statement that—
(i)
You will meet the requirements in §§ 63.1021 through 63.1037 that apply to your affected equipment.
(ii)
You have identified the equipment subject to control according to the requirements in § 63.1022, including equipment designated as unsafe to monitor, and have records supporting the determinations with a written plan for monitoring the equipment according to the requirements in § 63.1022(c)(4).
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.7922. How do I demonstrate continuous compliance with the work practice standards for equipment leaks?

40 C.F.R. § 63.7922

(a)
You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7920 applicable to your affected equipment by meeting the requirements in paragraphs (b) through (d) of this section that apply to you.
(b)
If you control equipment leaks according to the requirements under § 63.7920(b)(1), you must demonstrate continuous compliance by inspecting, monitoring, repairing, and maintaining records according to the requirements in §§ 63.1002 through 63.1018 that apply to your affected equipment.
(c)
If you control equipment leaks according to the requirements under § 63.7920(b)(2), you must demonstrate continuous compliance by inspecting, monitoring, repairing, and maintaining records according to the requirements in §§ 63.1021 through 63.1039 that apply to your affected equipment.
(d)
You must keep records to demonstrate compliance with the requirements according to the requirements in § 63.7952.
Notes, amendments, and revision history

Source

Source: 68 FR 58190, Oct. 8, 2003, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.