§63.7897. What are my inspection and monitoring requirements for tanks? — Inbound Citations

40 C.F.R. § 63.7897

Cited by 9 regulations in release Current.

Citations to 40 C.F.R. § 63.7897 as a whole

  • (a) For each site remediation with an affected source designated under § 63.7882, you must meet the standards specified in §§ 63.7885 through 63.7955, as applicable to your affected source, unless your site remediation meets the requirements for an exemption under paragraph (b) of this section.
  • (i) If the remediation material management unit is a tank, then you control HAP emissions according to the standards specified in §§ 63.7895 through 63.7898.
  • (a) For each closed-vent system and control device you use to comply with requirements in §§ 63.7890 through 63.7922, as applicable to your affected sources, you must meet the emissions limitations and work practice standards in this section.
  • (ii) You may not transfer the remediation material unless the owner or operator of the facility receiving your remediation material has submitted to the EPA a written certification that he or she will manage remediation material received from you according to the requirements of §§ 63.7885 through 63.7957. The receiving facility owner or operator may revoke the written certification by sending a written statement to the EPA and to you providing at least 90 days notice that they rescind acceptance of responsibility for compliance with the regulatory provisions listed in this section. Upon expiration of the notice period, you may not transfer your remediation material to the facility.

Citations to §63.7897(b)(1)

  • (b) You must inspect and monitor each of your tanks using Tank Level 2 controls according to the requirements in paragraphs (b)(1) through (5), as applicable to your tanks.
    (1) If you use a fixed roof with an internal floating roof according to § 63.7895(d)(1), you must visually inspect the fixed roof and internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
    (2) If you use an external floating roof according to § 63.7895(d)(2), you must visually inspect the external floating roof according to the requirements in § 63.1063(d)(1) and inspect the seals according to the requirements in § 63.1063(d)(2) and (3).
    (3) If you use a fixed roof vented to a control device according to § 63.7895(d)(3), you must meet requirements in paragraphs (b)(3)(i) and (ii) of this section.
    (i) You must visually inspect the fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
    (4) If you use a pressure tank according to § 63.7895(d)(4), you must visually inspect the tank and its closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h).
    (5) If you use a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5), you must meet requirements in paragraphs (b)(5)(i) and (ii) of this section.
    (i) You must perform the verification procedure for the permanent total enclosure at least annually according to the requirements in § 63.685(i).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.

Citations to §63.7897(b)(2)

  • (b) You must inspect and monitor each of your tanks using Tank Level 2 controls according to the requirements in paragraphs (b)(1) through (5), as applicable to your tanks.
    (1) If you use a fixed roof with an internal floating roof according to § 63.7895(d)(1), you must visually inspect the fixed roof and internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
    (2) If you use an external floating roof according to § 63.7895(d)(2), you must visually inspect the external floating roof according to the requirements in § 63.1063(d)(1) and inspect the seals according to the requirements in § 63.1063(d)(2) and (3).
    (3) If you use a fixed roof vented to a control device according to § 63.7895(d)(3), you must meet requirements in paragraphs (b)(3)(i) and (ii) of this section.
    (i) You must visually inspect the fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
    (4) If you use a pressure tank according to § 63.7895(d)(4), you must visually inspect the tank and its closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h).
    (5) If you use a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5), you must meet requirements in paragraphs (b)(5)(i) and (ii) of this section.
    (i) You must perform the verification procedure for the permanent total enclosure at least annually according to the requirements in § 63.685(i).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.

Citations to §63.7897(b)(3)

  • (b) You must inspect and monitor each of your tanks using Tank Level 2 controls according to the requirements in paragraphs (b)(1) through (5), as applicable to your tanks.
    (1) If you use a fixed roof with an internal floating roof according to § 63.7895(d)(1), you must visually inspect the fixed roof and internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
    (2) If you use an external floating roof according to § 63.7895(d)(2), you must visually inspect the external floating roof according to the requirements in § 63.1063(d)(1) and inspect the seals according to the requirements in § 63.1063(d)(2) and (3).
    (3) If you use a fixed roof vented to a control device according to § 63.7895(d)(3), you must meet requirements in paragraphs (b)(3)(i) and (ii) of this section.
    (i) You must visually inspect the fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
    (4) If you use a pressure tank according to § 63.7895(d)(4), you must visually inspect the tank and its closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h).
    (5) If you use a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5), you must meet requirements in paragraphs (b)(5)(i) and (ii) of this section.
    (i) You must perform the verification procedure for the permanent total enclosure at least annually according to the requirements in § 63.685(i).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.

Citations to §63.7897(b)(4)

  • (b) You must inspect and monitor each of your tanks using Tank Level 2 controls according to the requirements in paragraphs (b)(1) through (5), as applicable to your tanks.
    (1) If you use a fixed roof with an internal floating roof according to § 63.7895(d)(1), you must visually inspect the fixed roof and internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
    (2) If you use an external floating roof according to § 63.7895(d)(2), you must visually inspect the external floating roof according to the requirements in § 63.1063(d)(1) and inspect the seals according to the requirements in § 63.1063(d)(2) and (3).
    (3) If you use a fixed roof vented to a control device according to § 63.7895(d)(3), you must meet requirements in paragraphs (b)(3)(i) and (ii) of this section.
    (i) You must visually inspect the fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
    (4) If you use a pressure tank according to § 63.7895(d)(4), you must visually inspect the tank and its closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h).
    (5) If you use a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5), you must meet requirements in paragraphs (b)(5)(i) and (ii) of this section.
    (i) You must perform the verification procedure for the permanent total enclosure at least annually according to the requirements in § 63.685(i).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.

Citations to §63.7897(b)(5)

  • (b) You must inspect and monitor each of your tanks using Tank Level 2 controls according to the requirements in paragraphs (b)(1) through (5), as applicable to your tanks.
    (1) If you use a fixed roof with an internal floating roof according to § 63.7895(d)(1), you must visually inspect the fixed roof and internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
    (2) If you use an external floating roof according to § 63.7895(d)(2), you must visually inspect the external floating roof according to the requirements in § 63.1063(d)(1) and inspect the seals according to the requirements in § 63.1063(d)(2) and (3).
    (3) If you use a fixed roof vented to a control device according to § 63.7895(d)(3), you must meet requirements in paragraphs (b)(3)(i) and (ii) of this section.
    (i) You must visually inspect the fixed roof and closure devices for defects according to the requirements in § 63.695(b)(3).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.
    (4) If you use a pressure tank according to § 63.7895(d)(4), you must visually inspect the tank and its closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h).
    (5) If you use a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5), you must meet requirements in paragraphs (b)(5)(i) and (ii) of this section.
    (i) You must perform the verification procedure for the permanent total enclosure at least annually according to the requirements in § 63.685(i).
    (ii) You must monitor and inspect the closed vent system and control device according to the requirements in § 63.7927 that apply to you.