§63.485. Continuous front-end process vent provisions. — Inbound Citations

40 C.F.R. § 63.485

Cited by 103 regulations in release Current.

Citations to 40 C.F.R. § 63.485 as a whole

  • (v) Neoprene;
  • (2) Section 63.485 for continuous front-end process vents;
  • (i) The owner or operator of an affected source shall comply with this paragraph instead of § 63.120(d)(1)(ii) for the purposes of this subpart. If the control device used to comply with § 63.119(e) is also used to comply with any of the requirements found in §§ 63.485 through 63.501, the performance test required in or accepted by the applicable requirements in §§ 63.485 through 63.501 is acceptable for demonstrating compliance with § 63.119(e), for the purposes of this subpart. The owner or operator will not be required to prepare a design evaluation for the control device as described in § 63.120(d)(1)(i), if the performance test meets the criteria specified in paragraphs (i)(1) and (i)(2) of this section.
    (1) The performance test demonstrates that the control device achieves greater than or equal to the required control efficiency specified in § 63.119(e)(1) or § 63.119(e)(2), as applicable; and
    (2) The performance test is submitted as part of the Notification of Compliance Status required by § 63.506(e)(5). If the performance test report is submitted electronically through the EPA's CEDRI in accordance with § 63.152(h), the process unit(s) tested, the pollutant(s) tested, and the date that such performance test was conducted may be submitted in the notification of compliance status report in lieu of the performance test results. The performance test results must be submitted to CEDRI by the date the notification of compliance status report is submitted.
  • (a) This section applies to owners or operators of existing affected sources who seek to comply with § 63.483(b) by using emissions averaging rather than following the provisions of §§ 63.484, 63.485, 63.486, 63.494, and 63.501.
    (i) All emission points included in an emissions average shall be from the same affected source. There may be an emissions average for each individual affected source located at a plant site.
    (A) If a plant site has only one affected source for which emissions averaging is being used to demonstrate compliance, the number of emission points allowed to be included in the emission average is limited to twenty. This number may be increased by up to five additional points if pollution prevention measures are used to control five or more of the emission points included in the emissions average.
    (B) If a plant site has two or more affected sources for which emissions averaging is being used to demonstrate compliance, the number of emission points allowed in the emissions average for those affected sources is limited to twenty. This number may be increased by up to five additional emission points if pollution prevention measures are used to control five or more of the emission points included in the emissions averages.
    (2) Compliance with the provisions of this section may be based on either organic HAP or TOC.
    (3) For the purposes of the provisions in this section, whenever Method 18 of appendix A-6 to 40 CFR part 60 is specified within the paragraphs of this section or is specified by reference through provisions outside this section, Method 18 or Method 25A of appendices A-6 and A-7 to 40 CFR part 60, respectively, may be used. ASTM D6420-18 (incorporated by reference, see § 63.14) may also be used in lieu of Method 18, if the target compounds are all known and are all listed in Section 1.1 of ASTM D6420-18 as measurable; ASTM D6420-18 must not be used for methane and ethane; and ASTM D6420-18 may not be used as a total VOC method. The use of Method 25A, must conform with the requirements in paragraphs (a)(3)(i) and (ii) of this section.
    (i) The organic HAP used as the calibration gas for Method 25Aof appendix A-7 to 40 CFR part 60 must be the single organic HAP representing the largest percent by volume of the emissions.
    (ii) The use of Method 25A of appendix A-7 to 40 CFR part 60, is acceptable if the response from the high-level calibration gas is at least 20 times the standard deviation of the response from the zero calibration gas when the instrument is zeroed on the most sensitive scale.
  • (a) Performance testing shall be conducted in accordance with § 63.7(a)(1), (a)(3), (d), (e)(1) and (2), (e)(4), (g), and (h), with the exceptions specified in paragraphs (a)(1) through (5) of this section and the additions specified in paragraph (b) of this section. Sections 63.484 through 63.501 also contain specific testing requirements. Beginning no later than the compliance dates specified in § 63.481(n), conduct subsequent performance tests no later than 60 calendar months after the previous performance test.
    (1) Except as specified in paragraph (a)(1)(iii) of this section, performance tests shall be conducted at maximum representative operating conditions achievable during one of the time periods described in paragraph (a)(1)(i) of this section, without causing any of the situations described in paragraph (a)(1)(ii) of this section to occur. Upon request, the owner or operator shall make available to the Administrator such records as may be necessary to determine the conditions of performance tests.
    (i) The 6-month period that ends 2 months before the Notification of Compliance Status is due, according to § 63.506(e)(5); or the 6-month period that begins 3 months before the performance test and ends 3 months after the performance test.
    (ii) Causing damage to equipment; necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or necessitating that the owner or operator make product in excess of demand.
    (iii) Beginning no later than the compliance dates specified in § 63.481(n), paragraphs (a)(1)(i) and (ii) of this section no longer applies and instead the owner or operator must conduct performance tests under such conditions as the Administrator specifies based on representative performance of the affected source for the period being tested. Representative conditions exclude periods of startup and shutdown. You may not conduct performance tests during periods of malfunction. You must record the process information that is necessary to document operating conditions during the test and include in such record an explanation to support that such conditions represent normal operation. Upon request, you must make available to the Administrator such records as may be necessary to determine the conditions of performance tests.
    (2) References in § 63.7(g) to the Notification of Compliance Status requirements in § 63.9(h) shall refer to the requirements in § 63.506(e)(5).
    (3) Because the site-specific test plans in § 63.7(c)(3) are not required, § 63.7(h)(4)(ii) is not applicable.
    (4) The owner or operator shall notify the Administrator of the intent to conduct a performance test at least 30 days before the performance test is scheduled, to allow the Administrator the opportunity to have an observer present during the test. If after 30 days notice for an initially scheduled performance test, there is a delay (due to operational problems, etc.) in conducting the scheduled performance test, the owner or operator of an affected facility shall notify the Administrator as soon as possible of any delay in the original test date, either by providing at least 7 days prior notice of the rescheduled date of the performance test, or by arranging a rescheduled date with the Administrator by mutual agreement.
    (5) Performance tests shall be performed no later than 150 days after the compliance dates specified in this subpart (i.e., in time for the results to be included in the Notification of Compliance Status), rather than according to the time periods in § 63.7(a)(2).
  • (G) The information specified in paragraph (f) of this section shall be included in the Emissions Averaging Plan for:
    (1) Each continuous front-end process vent subject to § 63.485 controlled by a pollution prevention measure or control technique for which monitoring parameters or inspection procedures are not specified in § 63.114; and
    (2) Each storage vessel controlled by pollution prevention or a control technique other than an internal or external floating roof or a closed vent system with a control device.

Citations to §63.485(a)

Citations to §63.485(b)

Citations to §63.485(c)

Citations to §63.485(d)

Citations to §63.485(e)

Citations to §63.485(f)

Citations to §63.485(g)

Citations to §63.485(h)

Citations to §63.485(i)

Citations to §63.485(j)

Citations to §63.485(k)

  • (a) For each continuous front-end process vent located at an affected source, the owner or operator shall comply with the requirements of §§ 63.113 through 63.118, except as provided for in paragraphs (b) through (z) of this section. The owner or operator of continuous front-end process vents that are combined with one or more batch front-end process vents shall comply with paragraph (o) or (p) of this section.
  • (ii) For each monitored parameter for which a maximum or minimum level is required to be established under § 63.114(e) and § 63.485(k) for continuous front-end process vents, § 63.489 for batch front-end process vents and aggregate batch vent streams, § 63.497 for back-end process operations, § 63.143(f) for process wastewater, § 63.503(m) for emission points in emissions averages, paragraph (e)(8) of this section, or paragraph (f) of this section, the information specified in paragraphs (e)(5)(ii)(A) through (e)(5)(ii)(E) of this section shall be submitted in the Notification of Compliance Status, unless this information has been established and provided in the operating permit application. Further, as described in § 63.484(k), for those storage vessels for which the monitoring plan required by § 63.484(k) specifies compliance with the provisions of § 63.505, the owner or operator shall provide the information specified in paragraphs (e)(5)(ii)(A) through (e)(5)(ii)(D) of this section for each monitoring parameter, unless this information has been established and provided in the operating permit application. For those storage vessels for which the monitoring plan required by § 63.484(k) does not require compliance with the provisions of § 63.505, the owner or operator shall provide the information specified in § 63.120(d)(3) as part of the Notification of Compliance Status, unless this information has been established and provided in the operating permit application.
    (A) The required information shall include the specific maximum or minimum level of the monitored parameter(s) for each emission point.
    (B) The required information shall include the rationale for the specific maximum or minimum level for each parameter for each emission point, including any data and calculations used to develop the level and a description of why the level indicates proper operation of the control device.
    (C) The required information shall include a definition of the affected source's operating day, as specified in paragraph (d)(3)(ii) of this section, for purposes of determining daily average values of monitored parameters.
    (D) For batch front-end process vents, the required information shall include a definition of each batch cycle that requires the control of one or more batch emission episodes during the cycle, as specified in § 63.490(c)(2) and 63.505(b)(3)(iii).
    (E) The required information shall include a definition of the affected source's operating month for the purposes of determining monthly average values of residual organic HAP.
  • (1) Approval of alternatives to the requirements in §§ 63.480 through 63.481, 63.483(a) through (c), 63.484, 63.485(a) through (k), (m) through (s), (u), 63.486 through 63.487, 63.488(a), (b)(1) through (4), (5)(iv) through (v), (6) through (7), (c) through (i), 63.493 through 63.494, 63.500(a)(1) through (3), (b), 63.501, 63.502(a) through (f), (i), (k) through (m), and 63.503. Where these standards reference another subpart, the cited provisions will be delegated according to the delegation provisions of the referenced subpart. Where these standards reference another subpart and modify the requirements, the requirements shall be modified as described in this subpart. Delegation of the modified requirements will also occur according to the delegation provisions of the referenced subpart.

Citations to §63.485(l)

Citations to §63.485(l)(1)

  • (l) When reports of process changes are required under § 63.118(g), (h), (i), or (j), paragraphs (l)(1) through (l)(4) of this section shall apply for the purposes of this subpart. In addition, for the purposes of this subpart paragraph (l)(5) of this section applies, and § 63.118(k) does not apply to owners or operators of affected sources.
    (1) For the purposes of this subpart, whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent to become a Group 1 continuous front-end process vent, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator of the affected source shall comply with the Group 1 provisions in §§ 63.113 through 63.118 in accordance with § 63.480(i)(2)(ii) or (i)(2)(iii), as applicable.
    (2) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a TRE greater than 4.0 to become a Group 2 continuous front-end process vent with a TRE less than 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (3) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a flow rate less than 0.005 standard cubic meter per minute (scmm) to become a Group 2 continuous front-end process vent with a flow rate of 0.005 scmm or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (4) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with an organic HAP concentration less than 50 parts per million by volume (ppmv) to become a Group 2 continuous front-end process vent with an organic HAP concentration of 50 ppmv or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (5) The owner or operator is not required to submit a report of a process change if one of the conditions listed in paragraphs (l)(5)(i), (l)(5)(ii), (l)(5)(iii), or (l)(5)(iv) of this section is met.
    (i) The change does not meet the description of a process change in § 63.115(e);
    (ii) The vent stream flow rate is recalculated according to § 63.115(e) and the recalculated value is less than 0.005 standard cubic meter per minute;
    (iii) The organic HAP concentration of the vent stream is recalculated according to § 63.115(e) and the recalculated value is less than 50 parts per million by volume; or
    (iv) The TRE index value is recalculated according to § 63.115(e) and the recalculated value is greater than 4.0.

Citations to §63.485(l)(2)

  • (l) When reports of process changes are required under § 63.118(g), (h), (i), or (j), paragraphs (l)(1) through (l)(4) of this section shall apply for the purposes of this subpart. In addition, for the purposes of this subpart paragraph (l)(5) of this section applies, and § 63.118(k) does not apply to owners or operators of affected sources.
    (1) For the purposes of this subpart, whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent to become a Group 1 continuous front-end process vent, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator of the affected source shall comply with the Group 1 provisions in §§ 63.113 through 63.118 in accordance with § 63.480(i)(2)(ii) or (i)(2)(iii), as applicable.
    (2) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a TRE greater than 4.0 to become a Group 2 continuous front-end process vent with a TRE less than 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (3) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a flow rate less than 0.005 standard cubic meter per minute (scmm) to become a Group 2 continuous front-end process vent with a flow rate of 0.005 scmm or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (4) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with an organic HAP concentration less than 50 parts per million by volume (ppmv) to become a Group 2 continuous front-end process vent with an organic HAP concentration of 50 ppmv or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (5) The owner or operator is not required to submit a report of a process change if one of the conditions listed in paragraphs (l)(5)(i), (l)(5)(ii), (l)(5)(iii), or (l)(5)(iv) of this section is met.
    (i) The change does not meet the description of a process change in § 63.115(e);
    (ii) The vent stream flow rate is recalculated according to § 63.115(e) and the recalculated value is less than 0.005 standard cubic meter per minute;
    (iii) The organic HAP concentration of the vent stream is recalculated according to § 63.115(e) and the recalculated value is less than 50 parts per million by volume; or
    (iv) The TRE index value is recalculated according to § 63.115(e) and the recalculated value is greater than 4.0.

Citations to §63.485(l)(3)

  • (l) When reports of process changes are required under § 63.118(g), (h), (i), or (j), paragraphs (l)(1) through (l)(4) of this section shall apply for the purposes of this subpart. In addition, for the purposes of this subpart paragraph (l)(5) of this section applies, and § 63.118(k) does not apply to owners or operators of affected sources.
    (1) For the purposes of this subpart, whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent to become a Group 1 continuous front-end process vent, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator of the affected source shall comply with the Group 1 provisions in §§ 63.113 through 63.118 in accordance with § 63.480(i)(2)(ii) or (i)(2)(iii), as applicable.
    (2) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a TRE greater than 4.0 to become a Group 2 continuous front-end process vent with a TRE less than 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (3) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a flow rate less than 0.005 standard cubic meter per minute (scmm) to become a Group 2 continuous front-end process vent with a flow rate of 0.005 scmm or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (4) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with an organic HAP concentration less than 50 parts per million by volume (ppmv) to become a Group 2 continuous front-end process vent with an organic HAP concentration of 50 ppmv or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (5) The owner or operator is not required to submit a report of a process change if one of the conditions listed in paragraphs (l)(5)(i), (l)(5)(ii), (l)(5)(iii), or (l)(5)(iv) of this section is met.
    (i) The change does not meet the description of a process change in § 63.115(e);
    (ii) The vent stream flow rate is recalculated according to § 63.115(e) and the recalculated value is less than 0.005 standard cubic meter per minute;
    (iii) The organic HAP concentration of the vent stream is recalculated according to § 63.115(e) and the recalculated value is less than 50 parts per million by volume; or
    (iv) The TRE index value is recalculated according to § 63.115(e) and the recalculated value is greater than 4.0.

Citations to §63.485(l)(4)

  • (l) When reports of process changes are required under § 63.118(g), (h), (i), or (j), paragraphs (l)(1) through (l)(4) of this section shall apply for the purposes of this subpart. In addition, for the purposes of this subpart paragraph (l)(5) of this section applies, and § 63.118(k) does not apply to owners or operators of affected sources.
    (1) For the purposes of this subpart, whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent to become a Group 1 continuous front-end process vent, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator of the affected source shall comply with the Group 1 provisions in §§ 63.113 through 63.118 in accordance with § 63.480(i)(2)(ii) or (i)(2)(iii), as applicable.
    (2) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a TRE greater than 4.0 to become a Group 2 continuous front-end process vent with a TRE less than 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (3) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with a flow rate less than 0.005 standard cubic meter per minute (scmm) to become a Group 2 continuous front-end process vent with a flow rate of 0.005 scmm or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (4) Whenever a process change, as defined in § 63.115(e), is made that causes a Group 2 continuous front-end process vent with an organic HAP concentration less than 50 parts per million by volume (ppmv) to become a Group 2 continuous front-end process vent with an organic HAP concentration of 50 ppmv or greater and a TRE index value less than or equal to 4.0, the owner or operator shall submit a report within 180 days after the process change is made or with the next Periodic Report, whichever is later. A description of the process change shall be submitted with the report of the process change, and the owner or operator shall comply with the provisions in § 63.113(d) by the dates specified in § 63.481.
    (5) The owner or operator is not required to submit a report of a process change if one of the conditions listed in paragraphs (l)(5)(i), (l)(5)(ii), (l)(5)(iii), or (l)(5)(iv) of this section is met.
    (i) The change does not meet the description of a process change in § 63.115(e);
    (ii) The vent stream flow rate is recalculated according to § 63.115(e) and the recalculated value is less than 0.005 standard cubic meter per minute;
    (iii) The organic HAP concentration of the vent stream is recalculated according to § 63.115(e) and the recalculated value is less than 50 parts per million by volume; or
    (iv) The TRE index value is recalculated according to § 63.115(e) and the recalculated value is greater than 4.0.

Citations to §63.485(l)(6)

Citations to §63.485(m)

Citations to §63.485(n)

Citations to §63.485(o)

Citations to §63.485(o)(1)

Citations to §63.485(o)(1)(i)(A)

  • (i) All requirements for a Group 1 process vent stream in §§ 63.113 through 63.118, except as otherwise provided in this section. As specified in § 63.504(a)(1), performance tests shall be conducted at maximum representative operating conditions. For the purpose of conducting a performance test on a combined vent stream, maximum representative operating conditions shall be when batch emission episodes are occurring that result in the highest organic HAP emission rate (for the combined vent stream) that is achievable during one of the periods listed in § 63.504(a)(1)(i) or § 63.504(a)(1)(ii), without causing any of the situations described in paragraphs (o)(1)(i)(A) through (o)(1)(i)(C) of this section to occur.
    (A) Causing damage to equipment;
    (B) Necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or

Citations to §63.485(o)(1)(i)(B)

  • (i) All requirements for a Group 1 process vent stream in §§ 63.113 through 63.118, except as otherwise provided in this section. As specified in § 63.504(a)(1), performance tests shall be conducted at maximum representative operating conditions. For the purpose of conducting a performance test on a combined vent stream, maximum representative operating conditions shall be when batch emission episodes are occurring that result in the highest organic HAP emission rate (for the combined vent stream) that is achievable during one of the periods listed in § 63.504(a)(1)(i) or § 63.504(a)(1)(ii), without causing any of the situations described in paragraphs (o)(1)(i)(A) through (o)(1)(i)(C) of this section to occur.
    (A) Causing damage to equipment;
    (B) Necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or

Citations to §63.485(o)(1)(i)(C)

  • (i) All requirements for a Group 1 process vent stream in §§ 63.113 through 63.118, except as otherwise provided in this section. As specified in § 63.504(a)(1), performance tests shall be conducted at maximum representative operating conditions. For the purpose of conducting a performance test on a combined vent stream, maximum representative operating conditions shall be when batch emission episodes are occurring that result in the highest organic HAP emission rate (for the combined vent stream) that is achievable during one of the periods listed in § 63.504(a)(1)(i) or § 63.504(a)(1)(ii), without causing any of the situations described in paragraphs (o)(1)(i)(A) through (o)(1)(i)(C) of this section to occur.
    (A) Causing damage to equipment;
    (B) Necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or

Citations to §63.485(o)(2)

Citations to §63.485(o)(2)(i)

  • (2) If a batch front-end process vent or aggregate batch vent stream is combined with a continuous front-end process vent prior to the combined vent stream being routed to a recovery device, the TRE index value for the combined vent stream shall be calculated at the exit of the last recovery device. The TRE shall be calculated during periods when one or more batch emission episodes are occurring that result in the highest organic HAP emission rate (in the combined vent stream that is being routed to the recovery device) that is achievable during the 6-month period that begins 3 months before and ends 3 months after the TRE calculation, without causing any of the situations described in paragraphs (o)(2)(i) through (o)(2)(iii) of this section to occur.
    (i) Causing damage to equipment;
    (ii) Necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or

Citations to §63.485(o)(2)(ii)

  • (2) If a batch front-end process vent or aggregate batch vent stream is combined with a continuous front-end process vent prior to the combined vent stream being routed to a recovery device, the TRE index value for the combined vent stream shall be calculated at the exit of the last recovery device. The TRE shall be calculated during periods when one or more batch emission episodes are occurring that result in the highest organic HAP emission rate (in the combined vent stream that is being routed to the recovery device) that is achievable during the 6-month period that begins 3 months before and ends 3 months after the TRE calculation, without causing any of the situations described in paragraphs (o)(2)(i) through (o)(2)(iii) of this section to occur.
    (i) Causing damage to equipment;
    (ii) Necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or

Citations to §63.485(o)(2)(iii)

  • (2) If a batch front-end process vent or aggregate batch vent stream is combined with a continuous front-end process vent prior to the combined vent stream being routed to a recovery device, the TRE index value for the combined vent stream shall be calculated at the exit of the last recovery device. The TRE shall be calculated during periods when one or more batch emission episodes are occurring that result in the highest organic HAP emission rate (in the combined vent stream that is being routed to the recovery device) that is achievable during the 6-month period that begins 3 months before and ends 3 months after the TRE calculation, without causing any of the situations described in paragraphs (o)(2)(i) through (o)(2)(iii) of this section to occur.
    (i) Causing damage to equipment;
    (ii) Necessitating that the owner or operator make product that does not meet an existing specification for sale to a customer; or

Citations to §63.485(o)(6)

Citations to §63.485(p)

Citations to §63.485(p)(5)

Citations to §63.485(q)

Citations to §63.485(q)(1)

Citations to §63.485(q)(1)(iii)

  • (1) Group 1 halogenated continuous front-end process vents at existing affected sources producing butyl rubber or ethylene propylene rubber using a solution process are exempt from the provisions of § 63.113(a)(1)(ii) and § 63.113(c) if the conditions in paragraphs (q)(1)(i) and (ii) of this section are met, and shall comply with the requirements in paragraphs (q)(1)(iii) through (vi) of this section. Group 1 halogenated continuous front-end process vents at new affected sources producing butyl rubber or ethylene propylene rubber using a solution process are not exempt from § 63.113(a)(1)(ii) and § 63.113(c).
    (i) If the halogenated continuous front-end process vent stream was controlled by a combustion device prior to June 12, 1995; and
    (ii) Except as specified in paragraph (q)(3) of this section, if the requirements of § 63.113(a)(2); § 63.113(a)(3); § 63.113(b) and the associated testing requirements in § 63.116; or § 63.11(b) and § 63.504(c) are met.
    (iii) The average HCl emissions from all front-end process operations at affected sources producing butyl rubber and ethylene propylene rubber using a solution process shall not exceed the limits determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section for any consecutive 12-month period. The specific limitation for each elastomer type shall be determined based on the calculation or the emissions level provided in paragraphs (q)(1)(iii)(A) and (B) of this section divided by the base year elastomer product that leaves the stripping operation (or the reactor(s), if the plant has no stripper(s)). The limitation shall be calculated and submitted in accordance with paragraph (q)(1)(iv) of this section.
    (A) For butyl rubber, the HCl emission limitation shall be calculated using the following equation:
    (B) For ethylene propylene rubber using a solution process, the HCl emission limitation, in units of Mg HCl emissions per Mg of ethylene propylene rubber produced, shall be calculated by dividing 27 Mg/yr by the mass of ethylene propylene rubber produced in 2010, in Mg.
    (iv) If the front-end process operation is subject to a HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner and operator must submit the information specified in paragraphs (q)(1)(iv)(A) and (B) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section shall be submitted no later than 180 days from the date of publication of the final rule amendments in the Federal Register.
    (B) Beginning with the first periodic report required to be submitted by § 63.506(e)(6) that is at least 13 months after the compliance date, the total mass of HCl emitted for each of the rolling 12-month periods in the reporting period divided by the total mass of elastomer produced during the corresponding 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.
    (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.
    (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(iv)

  • (1) Group 1 halogenated continuous front-end process vents at existing affected sources producing butyl rubber or ethylene propylene rubber using a solution process are exempt from the provisions of § 63.113(a)(1)(ii) and § 63.113(c) if the conditions in paragraphs (q)(1)(i) and (ii) of this section are met, and shall comply with the requirements in paragraphs (q)(1)(iii) through (vi) of this section. Group 1 halogenated continuous front-end process vents at new affected sources producing butyl rubber or ethylene propylene rubber using a solution process are not exempt from § 63.113(a)(1)(ii) and § 63.113(c).
    (i) If the halogenated continuous front-end process vent stream was controlled by a combustion device prior to June 12, 1995; and
    (ii) Except as specified in paragraph (q)(3) of this section, if the requirements of § 63.113(a)(2); § 63.113(a)(3); § 63.113(b) and the associated testing requirements in § 63.116; or § 63.11(b) and § 63.504(c) are met.
    (iii) The average HCl emissions from all front-end process operations at affected sources producing butyl rubber and ethylene propylene rubber using a solution process shall not exceed the limits determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section for any consecutive 12-month period. The specific limitation for each elastomer type shall be determined based on the calculation or the emissions level provided in paragraphs (q)(1)(iii)(A) and (B) of this section divided by the base year elastomer product that leaves the stripping operation (or the reactor(s), if the plant has no stripper(s)). The limitation shall be calculated and submitted in accordance with paragraph (q)(1)(iv) of this section.
    (A) For butyl rubber, the HCl emission limitation shall be calculated using the following equation:
    (B) For ethylene propylene rubber using a solution process, the HCl emission limitation, in units of Mg HCl emissions per Mg of ethylene propylene rubber produced, shall be calculated by dividing 27 Mg/yr by the mass of ethylene propylene rubber produced in 2010, in Mg.
    (iv) If the front-end process operation is subject to a HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner and operator must submit the information specified in paragraphs (q)(1)(iv)(A) and (B) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section shall be submitted no later than 180 days from the date of publication of the final rule amendments in the Federal Register.
    (B) Beginning with the first periodic report required to be submitted by § 63.506(e)(6) that is at least 13 months after the compliance date, the total mass of HCl emitted for each of the rolling 12-month periods in the reporting period divided by the total mass of elastomer produced during the corresponding 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.
    (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.
    (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(v)

  • (1) Group 1 halogenated continuous front-end process vents at existing affected sources producing butyl rubber or ethylene propylene rubber using a solution process are exempt from the provisions of § 63.113(a)(1)(ii) and § 63.113(c) if the conditions in paragraphs (q)(1)(i) and (ii) of this section are met, and shall comply with the requirements in paragraphs (q)(1)(iii) through (vi) of this section. Group 1 halogenated continuous front-end process vents at new affected sources producing butyl rubber or ethylene propylene rubber using a solution process are not exempt from § 63.113(a)(1)(ii) and § 63.113(c).
    (i) If the halogenated continuous front-end process vent stream was controlled by a combustion device prior to June 12, 1995; and
    (ii) Except as specified in paragraph (q)(3) of this section, if the requirements of § 63.113(a)(2); § 63.113(a)(3); § 63.113(b) and the associated testing requirements in § 63.116; or § 63.11(b) and § 63.504(c) are met.
    (iii) The average HCl emissions from all front-end process operations at affected sources producing butyl rubber and ethylene propylene rubber using a solution process shall not exceed the limits determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section for any consecutive 12-month period. The specific limitation for each elastomer type shall be determined based on the calculation or the emissions level provided in paragraphs (q)(1)(iii)(A) and (B) of this section divided by the base year elastomer product that leaves the stripping operation (or the reactor(s), if the plant has no stripper(s)). The limitation shall be calculated and submitted in accordance with paragraph (q)(1)(iv) of this section.
    (A) For butyl rubber, the HCl emission limitation shall be calculated using the following equation:
    (B) For ethylene propylene rubber using a solution process, the HCl emission limitation, in units of Mg HCl emissions per Mg of ethylene propylene rubber produced, shall be calculated by dividing 27 Mg/yr by the mass of ethylene propylene rubber produced in 2010, in Mg.
    (iv) If the front-end process operation is subject to a HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner and operator must submit the information specified in paragraphs (q)(1)(iv)(A) and (B) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section shall be submitted no later than 180 days from the date of publication of the final rule amendments in the Federal Register.
    (B) Beginning with the first periodic report required to be submitted by § 63.506(e)(6) that is at least 13 months after the compliance date, the total mass of HCl emitted for each of the rolling 12-month periods in the reporting period divided by the total mass of elastomer produced during the corresponding 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.
    (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.
    (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(v)(A)

  • (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.

Citations to §63.485(q)(1)(v)(B)

  • (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.

Citations to §63.485(q)(1)(v)(C)

  • (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.

Citations to §63.485(q)(1)(v)(D)

  • (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.

Citations to §63.485(q)(1)(v)(E)

  • (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.

Citations to §63.485(q)(1)(vi)

  • (1) Group 1 halogenated continuous front-end process vents at existing affected sources producing butyl rubber or ethylene propylene rubber using a solution process are exempt from the provisions of § 63.113(a)(1)(ii) and § 63.113(c) if the conditions in paragraphs (q)(1)(i) and (ii) of this section are met, and shall comply with the requirements in paragraphs (q)(1)(iii) through (vi) of this section. Group 1 halogenated continuous front-end process vents at new affected sources producing butyl rubber or ethylene propylene rubber using a solution process are not exempt from § 63.113(a)(1)(ii) and § 63.113(c).
    (i) If the halogenated continuous front-end process vent stream was controlled by a combustion device prior to June 12, 1995; and
    (ii) Except as specified in paragraph (q)(3) of this section, if the requirements of § 63.113(a)(2); § 63.113(a)(3); § 63.113(b) and the associated testing requirements in § 63.116; or § 63.11(b) and § 63.504(c) are met.
    (iii) The average HCl emissions from all front-end process operations at affected sources producing butyl rubber and ethylene propylene rubber using a solution process shall not exceed the limits determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section for any consecutive 12-month period. The specific limitation for each elastomer type shall be determined based on the calculation or the emissions level provided in paragraphs (q)(1)(iii)(A) and (B) of this section divided by the base year elastomer product that leaves the stripping operation (or the reactor(s), if the plant has no stripper(s)). The limitation shall be calculated and submitted in accordance with paragraph (q)(1)(iv) of this section.
    (A) For butyl rubber, the HCl emission limitation shall be calculated using the following equation:
    (B) For ethylene propylene rubber using a solution process, the HCl emission limitation, in units of Mg HCl emissions per Mg of ethylene propylene rubber produced, shall be calculated by dividing 27 Mg/yr by the mass of ethylene propylene rubber produced in 2010, in Mg.
    (iv) If the front-end process operation is subject to a HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner and operator must submit the information specified in paragraphs (q)(1)(iv)(A) and (B) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section shall be submitted no later than 180 days from the date of publication of the final rule amendments in the Federal Register.
    (B) Beginning with the first periodic report required to be submitted by § 63.506(e)(6) that is at least 13 months after the compliance date, the total mass of HCl emitted for each of the rolling 12-month periods in the reporting period divided by the total mass of elastomer produced during the corresponding 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.
    (v) Compliance with the HCl emission limitations determined in accordance with paragraph (q)(1)(iii) of this section shall be demonstrated in accordance with paragraphs (q)(1)(v)(A) through (E) of this section.
    (A) Calculate your HCl emission limitation in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section, as applicable, record it, and submit it in accordance with paragraph (q)(1)(iv) of this section.
    (B) Each month, calculate and record the HCl emissions from all front-end process operations using engineering assessment. Engineering assessment includes, but is not limited to, the following:
    (1) Use of material balances;
    (2) Estimation of flow rate based on physical equipment design, such as pump or blower capacities;
    (3) Estimation of HCl concentrations based on saturation conditions; and
    (4) Estimation of HCl concentrations based on grab samples of the liquid or vapor.
    (D) Each month, calculate and record the sum of the HCl emissions and the mass of elastomer produced for the previous calendar 12-month period.
    (E) Each month, divide the total mass of HCl emitted for the previous calendar 12-month period by the total mass of elastomer produced during this 12-month period. This value must be recorded in accordance with paragraph (q)(1)(vi) of this section and reported in accordance with paragraph (q)(1)(iv) of this section.
    (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(vi)(A)

  • (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(vi)(B)

  • (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(vi)(C)

  • (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(vi)(D)

  • (vi) If the front-end process operation is subject to an HCl emission limitation in paragraph (q)(1)(iii) of this section, the owner or operator shall maintain the records specified in paragraphs (q)(1)(vi)(A) through (D) of this section.
    (A) The applicable HCl emission limitation determined in accordance with paragraphs (q)(1)(iii)(A) and (B) of this section.
    (B) The HCl emissions from all front-end process operations for each month, along with documentation of all calculations, and other information used in the engineering assessment to estimate these emissions.
    (D) The total mass of HCl emitted for each 12-month period divided by the total mass of elastomer produced during the 12-month period, determined in accordance with paragraph (q)(1)(v) of this section.

Citations to §63.485(q)(1)(vii)

Citations to §63.485(q)(1)(x)

Citations to §63.485(r)

Citations to §63.485(s)

Citations to §63.485(s)(1)

  • (s) In addition to the three options for the control of a Group 1 continuous front-end process vent listed in § 63.113(a)(1) through (3), except as specified in § 63.113(a)(4) of subpart G of this part, an owner or operator will be permitted to route emissions of organic HAP to an internal combustion engine, provided the conditions listed in paragraphs (s)(1) through (s)(5) of this section are met.
    (1) The vent stream routed to the internal combustion engine shall not be a halogenated continuous front-end process vent stream.
    (3) The internal combustion engine is operating at all times that organic HAP emissions are being routed to it. The owner or operator shall demonstrate that the internal combustion engine is operating by continuously monitoring the on/off status of the internal combustion engine.
    (4) The owner or operator shall maintain hourly records verifying that the internal combustion engine was operating at all times that emissions were routed to it.
    (5) The owner or operator shall include in the Periodic Report a report of all times that the internal combustion engine was not operating while emissions were being routed to it. Include the start date and time and end date and time for all such periods.
    (6) If an internal combustion engine meeting the requirements of paragraphs (s)(1) through (5) of this section is used to comply with the provisions of § 63.113(a), the internal combustion engine is exempt from the source testing requirements of § 63.116.

Citations to §63.485(s)(2)

  • (s) In addition to the three options for the control of a Group 1 continuous front-end process vent listed in § 63.113(a)(1) through (3), except as specified in § 63.113(a)(4) of subpart G of this part, an owner or operator will be permitted to route emissions of organic HAP to an internal combustion engine, provided the conditions listed in paragraphs (s)(1) through (s)(5) of this section are met.
    (1) The vent stream routed to the internal combustion engine shall not be a halogenated continuous front-end process vent stream.
    (3) The internal combustion engine is operating at all times that organic HAP emissions are being routed to it. The owner or operator shall demonstrate that the internal combustion engine is operating by continuously monitoring the on/off status of the internal combustion engine.
    (4) The owner or operator shall maintain hourly records verifying that the internal combustion engine was operating at all times that emissions were routed to it.
    (5) The owner or operator shall include in the Periodic Report a report of all times that the internal combustion engine was not operating while emissions were being routed to it. Include the start date and time and end date and time for all such periods.
    (6) If an internal combustion engine meeting the requirements of paragraphs (s)(1) through (5) of this section is used to comply with the provisions of § 63.113(a), the internal combustion engine is exempt from the source testing requirements of § 63.116.

Citations to §63.485(s)(3)

  • (s) In addition to the three options for the control of a Group 1 continuous front-end process vent listed in § 63.113(a)(1) through (3), except as specified in § 63.113(a)(4) of subpart G of this part, an owner or operator will be permitted to route emissions of organic HAP to an internal combustion engine, provided the conditions listed in paragraphs (s)(1) through (s)(5) of this section are met.
    (1) The vent stream routed to the internal combustion engine shall not be a halogenated continuous front-end process vent stream.
    (3) The internal combustion engine is operating at all times that organic HAP emissions are being routed to it. The owner or operator shall demonstrate that the internal combustion engine is operating by continuously monitoring the on/off status of the internal combustion engine.
    (4) The owner or operator shall maintain hourly records verifying that the internal combustion engine was operating at all times that emissions were routed to it.
    (5) The owner or operator shall include in the Periodic Report a report of all times that the internal combustion engine was not operating while emissions were being routed to it. Include the start date and time and end date and time for all such periods.
    (6) If an internal combustion engine meeting the requirements of paragraphs (s)(1) through (5) of this section is used to comply with the provisions of § 63.113(a), the internal combustion engine is exempt from the source testing requirements of § 63.116.

Citations to §63.485(s)(4)

  • (s) In addition to the three options for the control of a Group 1 continuous front-end process vent listed in § 63.113(a)(1) through (3), except as specified in § 63.113(a)(4) of subpart G of this part, an owner or operator will be permitted to route emissions of organic HAP to an internal combustion engine, provided the conditions listed in paragraphs (s)(1) through (s)(5) of this section are met.
    (1) The vent stream routed to the internal combustion engine shall not be a halogenated continuous front-end process vent stream.
    (3) The internal combustion engine is operating at all times that organic HAP emissions are being routed to it. The owner or operator shall demonstrate that the internal combustion engine is operating by continuously monitoring the on/off status of the internal combustion engine.
    (4) The owner or operator shall maintain hourly records verifying that the internal combustion engine was operating at all times that emissions were routed to it.
    (5) The owner or operator shall include in the Periodic Report a report of all times that the internal combustion engine was not operating while emissions were being routed to it. Include the start date and time and end date and time for all such periods.
    (6) If an internal combustion engine meeting the requirements of paragraphs (s)(1) through (5) of this section is used to comply with the provisions of § 63.113(a), the internal combustion engine is exempt from the source testing requirements of § 63.116.

Citations to §63.485(s)(5)

  • (s) In addition to the three options for the control of a Group 1 continuous front-end process vent listed in § 63.113(a)(1) through (3), except as specified in § 63.113(a)(4) of subpart G of this part, an owner or operator will be permitted to route emissions of organic HAP to an internal combustion engine, provided the conditions listed in paragraphs (s)(1) through (s)(5) of this section are met.
    (1) The vent stream routed to the internal combustion engine shall not be a halogenated continuous front-end process vent stream.
    (3) The internal combustion engine is operating at all times that organic HAP emissions are being routed to it. The owner or operator shall demonstrate that the internal combustion engine is operating by continuously monitoring the on/off status of the internal combustion engine.
    (4) The owner or operator shall maintain hourly records verifying that the internal combustion engine was operating at all times that emissions were routed to it.
    (5) The owner or operator shall include in the Periodic Report a report of all times that the internal combustion engine was not operating while emissions were being routed to it. Include the start date and time and end date and time for all such periods.
    (6) If an internal combustion engine meeting the requirements of paragraphs (s)(1) through (5) of this section is used to comply with the provisions of § 63.113(a), the internal combustion engine is exempt from the source testing requirements of § 63.116.
  • (A) All information specified in § 63.122(a)(4) for storage vessels, §§ 63.117(a)(3) and 63.118(f) and 63.485(s)(5) for continuous front-end process vents, § 63.492 for batch front-end process vents and aggregate batch vent streams, § 63.499 for back-end process operations, § 63.104(f)(2) for heat exchange systems, and § 63.146(c) through (g) for process wastewater.

Citations to §63.485(t)

Citations to §63.485(u)

Citations to §63.485(v)

Citations to §63.485(w)

Citations to §63.485(x)

Citations to §63.485(x)(1)

  • (x) Owners and operators of affected sources must make the substitutions as specified in paragraphs (x)(1) through (4) of this section:
    (1) Substitute “For each affected source as described in § 63.480” for each occurrence of the phrase “For each source as defined in § 63.101”.
    (2) Substitute “beginning no later than the compliance dates specified in § 63.481(n)” for each occurrence of the phrase “beginning no later than the compliance dates specified in § 63.100(k)(10)”.
    (3) Substitute “owners and operators of affected sources as described in § 63.480” for each occurrence of the phrase “owners and operators of sources as defined in § 63.101”.
    (4) Substitute “§ 63.508” for each occurrence of “§ 63.108”.

Citations to §63.485(x)(2)

  • (x) Owners and operators of affected sources must make the substitutions as specified in paragraphs (x)(1) through (4) of this section:
    (1) Substitute “For each affected source as described in § 63.480” for each occurrence of the phrase “For each source as defined in § 63.101”.
    (2) Substitute “beginning no later than the compliance dates specified in § 63.481(n)” for each occurrence of the phrase “beginning no later than the compliance dates specified in § 63.100(k)(10)”.
    (3) Substitute “owners and operators of affected sources as described in § 63.480” for each occurrence of the phrase “owners and operators of sources as defined in § 63.101”.
    (4) Substitute “§ 63.508” for each occurrence of “§ 63.108”.

Citations to §63.485(x)(3)

  • (x) Owners and operators of affected sources must make the substitutions as specified in paragraphs (x)(1) through (4) of this section:
    (1) Substitute “For each affected source as described in § 63.480” for each occurrence of the phrase “For each source as defined in § 63.101”.
    (2) Substitute “beginning no later than the compliance dates specified in § 63.481(n)” for each occurrence of the phrase “beginning no later than the compliance dates specified in § 63.100(k)(10)”.
    (3) Substitute “owners and operators of affected sources as described in § 63.480” for each occurrence of the phrase “owners and operators of sources as defined in § 63.101”.
    (4) Substitute “§ 63.508” for each occurrence of “§ 63.108”.

Citations to §63.485(x)(4)

  • (x) Owners and operators of affected sources must make the substitutions as specified in paragraphs (x)(1) through (4) of this section:
    (1) Substitute “For each affected source as described in § 63.480” for each occurrence of the phrase “For each source as defined in § 63.101”.
    (2) Substitute “beginning no later than the compliance dates specified in § 63.481(n)” for each occurrence of the phrase “beginning no later than the compliance dates specified in § 63.100(k)(10)”.
    (3) Substitute “owners and operators of affected sources as described in § 63.480” for each occurrence of the phrase “owners and operators of sources as defined in § 63.101”.
    (4) Substitute “§ 63.508” for each occurrence of “§ 63.108”.

Citations to §63.485(y)

Citations to §63.485(y)(1)

  • (y) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(o), if the Group 1 or Group 2 continuous front-end process vent contains chloroprene such that it is considered to be in chloroprene service, as defined in § 63.482, then the owner or operator must comply with the requirements of paragraphs (y)(1) through (4) of this section in addition to all other applicable requirements specified in § 63.483 and elsewhere in this section.
    (1) Reduce emissions of chloroprene by venting emissions through a closed vent system to a non-flare control device that reduces chloroprene by greater than or equal to 98 percent by weight, or to a concentration less than 1 ppmv for each process vent or to less than 5 pounds per year for all combined process vents within the process. If a combustion device is used, the chloroprene concentration of 1 ppmv must be corrected to 3 percent oxygen.
    (2) To demonstrate compliance with the emission limits specified in paragraph (y)(1) of this section for continuous front-end process vents in chloroprene service, owners and operators must meet the requirements specified in § 63.510.
    (3) Owners and operators must keep the records specified in paragraphs (y)(3)(i) and (y)(3)(ii) of this section in addition to those records specified elsewhere in this section.
    (i) For process vents, include all uncontrolled, undiluted chloroprene concentration measurements, and the calculations used to determine the total uncontrolled chloroprene mass emission rate for the sum of all vent gas streams.
    (ii) The owner or operator must keep records of all periods during which operating values are outside of the applicable operating limits specified in § 63.510(b)(4) through (6) when regulated material is being routed to the non-flare control device. The record must specify the operating parameter, the applicable limit, and the highest (for maximum operating limits) or lowest (for minimum operating limits) value recorded during the period.
    (4) The Periodic Report must include the records for the periods specified in paragraph (y)(3)(ii) of this section. Indicate the start date, start time and duration in hours for each period.

Citations to §63.485(y)(2)

  • (y) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(o), if the Group 1 or Group 2 continuous front-end process vent contains chloroprene such that it is considered to be in chloroprene service, as defined in § 63.482, then the owner or operator must comply with the requirements of paragraphs (y)(1) through (4) of this section in addition to all other applicable requirements specified in § 63.483 and elsewhere in this section.
    (1) Reduce emissions of chloroprene by venting emissions through a closed vent system to a non-flare control device that reduces chloroprene by greater than or equal to 98 percent by weight, or to a concentration less than 1 ppmv for each process vent or to less than 5 pounds per year for all combined process vents within the process. If a combustion device is used, the chloroprene concentration of 1 ppmv must be corrected to 3 percent oxygen.
    (2) To demonstrate compliance with the emission limits specified in paragraph (y)(1) of this section for continuous front-end process vents in chloroprene service, owners and operators must meet the requirements specified in § 63.510.
    (3) Owners and operators must keep the records specified in paragraphs (y)(3)(i) and (y)(3)(ii) of this section in addition to those records specified elsewhere in this section.
    (i) For process vents, include all uncontrolled, undiluted chloroprene concentration measurements, and the calculations used to determine the total uncontrolled chloroprene mass emission rate for the sum of all vent gas streams.
    (ii) The owner or operator must keep records of all periods during which operating values are outside of the applicable operating limits specified in § 63.510(b)(4) through (6) when regulated material is being routed to the non-flare control device. The record must specify the operating parameter, the applicable limit, and the highest (for maximum operating limits) or lowest (for minimum operating limits) value recorded during the period.
    (4) The Periodic Report must include the records for the periods specified in paragraph (y)(3)(ii) of this section. Indicate the start date, start time and duration in hours for each period.

Citations to §63.485(y)(3)

  • (y) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(o), if the Group 1 or Group 2 continuous front-end process vent contains chloroprene such that it is considered to be in chloroprene service, as defined in § 63.482, then the owner or operator must comply with the requirements of paragraphs (y)(1) through (4) of this section in addition to all other applicable requirements specified in § 63.483 and elsewhere in this section.
    (1) Reduce emissions of chloroprene by venting emissions through a closed vent system to a non-flare control device that reduces chloroprene by greater than or equal to 98 percent by weight, or to a concentration less than 1 ppmv for each process vent or to less than 5 pounds per year for all combined process vents within the process. If a combustion device is used, the chloroprene concentration of 1 ppmv must be corrected to 3 percent oxygen.
    (2) To demonstrate compliance with the emission limits specified in paragraph (y)(1) of this section for continuous front-end process vents in chloroprene service, owners and operators must meet the requirements specified in § 63.510.
    (3) Owners and operators must keep the records specified in paragraphs (y)(3)(i) and (y)(3)(ii) of this section in addition to those records specified elsewhere in this section.
    (i) For process vents, include all uncontrolled, undiluted chloroprene concentration measurements, and the calculations used to determine the total uncontrolled chloroprene mass emission rate for the sum of all vent gas streams.
    (ii) The owner or operator must keep records of all periods during which operating values are outside of the applicable operating limits specified in § 63.510(b)(4) through (6) when regulated material is being routed to the non-flare control device. The record must specify the operating parameter, the applicable limit, and the highest (for maximum operating limits) or lowest (for minimum operating limits) value recorded during the period.
    (4) The Periodic Report must include the records for the periods specified in paragraph (y)(3)(ii) of this section. Indicate the start date, start time and duration in hours for each period.

Citations to §63.485(y)(4)

  • (y) For each affected source as described in § 63.480, beginning no later than the compliance dates specified in § 63.481(o), if the Group 1 or Group 2 continuous front-end process vent contains chloroprene such that it is considered to be in chloroprene service, as defined in § 63.482, then the owner or operator must comply with the requirements of paragraphs (y)(1) through (4) of this section in addition to all other applicable requirements specified in § 63.483 and elsewhere in this section.
    (1) Reduce emissions of chloroprene by venting emissions through a closed vent system to a non-flare control device that reduces chloroprene by greater than or equal to 98 percent by weight, or to a concentration less than 1 ppmv for each process vent or to less than 5 pounds per year for all combined process vents within the process. If a combustion device is used, the chloroprene concentration of 1 ppmv must be corrected to 3 percent oxygen.
    (2) To demonstrate compliance with the emission limits specified in paragraph (y)(1) of this section for continuous front-end process vents in chloroprene service, owners and operators must meet the requirements specified in § 63.510.
    (3) Owners and operators must keep the records specified in paragraphs (y)(3)(i) and (y)(3)(ii) of this section in addition to those records specified elsewhere in this section.
    (i) For process vents, include all uncontrolled, undiluted chloroprene concentration measurements, and the calculations used to determine the total uncontrolled chloroprene mass emission rate for the sum of all vent gas streams.
    (ii) The owner or operator must keep records of all periods during which operating values are outside of the applicable operating limits specified in § 63.510(b)(4) through (6) when regulated material is being routed to the non-flare control device. The record must specify the operating parameter, the applicable limit, and the highest (for maximum operating limits) or lowest (for minimum operating limits) value recorded during the period.
    (4) The Periodic Report must include the records for the periods specified in paragraph (y)(3)(ii) of this section. Indicate the start date, start time and duration in hours for each period.

Citations to §63.485(z)

  • (o) All affected sources that commenced construction or reconstruction on or before April 25, 2023, must be in compliance with the chloroprene requirements in §§ 63.484(u), 63.485(y) and (z), 63.487(j), 63.494(a)(7), 63.501(a)(10)(iv), 63.502(a)(3) and (a)(7), 63.509, and 63.510 upon initial startup or on October 15, 2024, whichever is later. All affected sources that commenced construction or reconstruction after April 25, 2023, must be in compliance with the chloroprene requirements in §§ 63.484(u), 63.485(x) and (z), 63.487(j), 63.494(a)(7), § 63.501(a)(10)(iv), 63.502(q), 63.502(a)(3) and (a)(7), 63.509, and 63.510 upon initial startup, or on July 15, 2024, whichever is later.
  • (a) For each continuous front-end process vent located at an affected source, the owner or operator shall comply with the requirements of §§ 63.113 through 63.118, except as provided for in paragraphs (b) through (z) of this section. The owner or operator of continuous front-end process vents that are combined with one or more batch front-end process vents shall comply with paragraph (o) or (p) of this section.
  • (4) In addition to complying with the requirements in paragraphs (i)(1) through (i)(3) of this section, for batch front-end process vents that are in chloroprene service and subject to the requirements of § 63.510 that are designated as maintenance vents, owners and operators may not release more than 1.0 tons of chloroprene from all maintenance vents combined (i.e., including maintenance vents subject to this paragraph (i)(4), § 63.485(z), or § 63.494(a)(7)(iii)) per any consecutive 12-month period. The owner or operator must keep monthly records of the quantity in tons of chloroprene released from each maintenance vent and include a description of the method used to estimate this quantity.
  • (iii) An owner or operator may designate a back-end process vent in chloroprene service as a maintenance vent if the vent is only used as a result of startup, shutdown, maintenance, or inspection of equipment where equipment is emptied, depressurized, degassed, or placed into service; however, owners and operators may not release more than 1.0 tons of chloroprene from all maintenance vents combined (i.e., including maintenance vents subject to this paragraph (a)(7)(iii), § 63.485(z), or § 63.487(i)(4)) per any consecutive 12-month period. The owner or operator must keep monthly records of the quantity in tons of chloroprene released from each maintenance vent and include a description of the method used to estimate this quantity.