§63.115. Process vent provisions—methods and procedures for process vent group determination.
40 C.F.R. § 63.115
(1) Use of material balances based on process stoichiometry to estimate maximum organic HAP concentrations,
(2) Estimation of maximum flow rate based on physical equipment design such as pump or blower capacities,
(3) Estimation of TOC or organic HAP concentrations based on saturation conditions,
(4) Estimation of maximum expected net heating value based on the vent stream concentration of each organic compound or, alternatively, as if all TOC in the vent stream were the compound with the highest heating value.
(1) Process knowledge that no halogen or hydrogen halides are present in the process, or
(2) Applicable engineering assessment as discussed in paragraph (d)(1)(iii) of this section, or
(3) Concentration of organic compounds containing halogens measured by Method 18 of 40 CFR part 60, appendix A, or
(4) Any other method or data that has been validated according to the applicable procedures in Method 301 of appendix A of this part.
Notes, amendments, and revision history
Amendments
[59 FR 19468, Apr. 22, 1994, as amended at 62 FR 2746, Jan. 17, 1997; 66 FR 6931, Jan. 22, 2001; 89 FR 43181, May 16, 2024]
Source
Source: 59 FR 19468, Apr. 22, 1994, unless otherwise noted.
Authority
Authority: 42 U.S.C. 7401 et seq.
Source
Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.
Amendments