§63.364. Monitoring requirements.
40 C.F.R. § 63.364
(1) Weigh the EtO gas cylinder(s) used to charge the sterilizer(s) before and after charging. Record these weights to the nearest 45 g (0.1 lb) and calculate the theoretical mass (Mc) vented to the controls using equation 1 to this paragraph.
(2) Install a calibrated rate meter at the sterilizer inlet(s) and continuously measure the flow rate (Qm) and duration of each sterilizer charge. Calculate the theoretical mass (MSCV,n) vented to the controls using equation 2 to this paragraph.
(2) If both this approach is chosen and the SCV is (or SCVs are) combined with another emission stream, then the owner or operator cannot monitor the point after the combination occurs.
(1) Install the required CEMS in the ducts from each emission source that is subject to this rule, leading to the common stack; or
(2) Install the required CEMS described in this section in the common stack and attribute all of the emissions measured at the common stack to the emission source(s).
(1) For each hour in which valid data are obtained for all parameters, you must calculate the pollutant emission rate; and
(2) You must assign the calculated pollutant emission rate to each of the units subject to the rule that share the common stack.