US Codex
C.F.R.
Browse by date
Notes

40 C.F.R. §§ 63.1157–63.1159

3 sections in range

§63.1157. Emission standards for existing sources.

40 C.F.R. § 63.1157

(a)
Pickling lines. No owner or operator of an existing affected continuous or batch pickling line at a steel pickling facility shall cause or allow to be discharged into the atmosphere from the affected pickling line:
(1)
Any gases that contain HCl in a concentration in excess of 18 parts per million by volume (ppmv); or
(2)
HCl at a mass emission rate that corresponds to a collection efficiency of less than 97 percent.
(b)
Hydrochloric acid regeneration plants.
(1)
No owner or operator of an existing affected plant shall cause or allow to be discharged into the atmosphere from the affected plant any gases that contain HCl in a concentration greater than 25 ppmv.
(2)
In addition to the requirement of paragraph (b)(1) of this section, no owner or operator of an existing plant shall cause or allow to be discharged into the atmosphere from the affected plant any gases that contain chlorine (Cl2) in a concentration in excess of 6 ppmv.
Notes, amendments, and revision history

Amendments

[64 FR 33218, June 22, 1999, as amended at 77 FR 58250, Sept. 19, 2012]

Source

Source: 64 FR 33218, June 22, 1999, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments

[64 FR 33218, June 22, 1999, as amended at 77 FR 58250, Sept. 19, 2012]

§63.1158. Emission standards for new or reconstructed sources.

40 C.F.R. § 63.1158

(a)
Pickling lines—
(1)
Continuous pickling lines. No owner or operator of a new or reconstructed affected continuous pickling line at a steel pickling facility shall cause or allow to be discharged into the atmosphere from the affected pickling line:
(i)
Any gases that contain HCl in a concentration in excess of 6 ppmv; or
(ii)
HCl at a mass emission rate that corresponds to a collection efficiency of less than 99 percent.
(2)
Batch pickling lines. No owner or operator of a new or reconstructed affected batch pickling line at a steel pickling facility shall cause or allow to be discharged into the atmosphere from the affected pickling line:
(i)
Any gases that contain HCl in a concentration in excess of 18 ppmv; or
(ii)
HCl at a mass emission rate that corresponds to a collection efficiency of less than 97 percent.
(b)
Hydrochloric acid regeneration plants.
(1)
No owner or operator of a new or reconstructed affected plant shall cause or allow to be discharged into the atmosphere from the affected plant any gases that contain HCl in a concentration greater than 12 ppmv.
(2)
In addition to the requirement of paragraph (b)(1) of this section, no owner or operator of a new or reconstructed affected plant shall cause or allow to be discharged into the atmosphere from the affected plant any gases that contain Cl2 in a concentration in excess of 6 ppmv.
Notes, amendments, and revision history

Source

Source: 64 FR 33218, June 22, 1999, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

§63.1159. Operational and equipment standards for existing, new, or reconstructed sources.

40 C.F.R. § 63.1159

(a)
Hydrochloric acid regeneration plant. The owner or operator of an affected plant must operate the affected plant at all times while in production mode in a manner that minimizes the proportion of excess air fed to the process and maximizes the process offgas temperature consistent with producing usable regenerated acid or iron oxide.
(b)
Hydrochloric acid storage vessels. The owner or operator of an affected vessel shall provide and operate, except during loading and unloading of acid, a closed-vent system for each vessel. Loading and unloading shall be conducted either through enclosed lines or each point where the acid is exposed to the atmosphere shall be equipped with a local fume capture system, ventilated through an air pollution control device.
(c)
General duty to minimize emissions. At all times, each owner or operator must operate and maintain any affected source subject to the requirements of this subpart, including associated air pollution control equipment and monitoring equipment in a manner consistent with safety and good air pollution control practices for minimizing emissions. The general duty to minimize emissions does not require the owner or operator to make any further efforts to reduce emissions if levels required by this standard have been achieved. Determination of whether such operation and maintenance procedures are being used will be based on information available to the Administrator which may include, but is not limited to, monitoring results, review of operation and maintenance procedures, review of operation and maintenance records, and inspection of the source.
Notes, amendments, and revision history

Amendments

[64 FR 33218, June 22, 1999, as amended at 77 FR 58250, Sept. 19, 2012]

Source

Source: 64 FR 33218, June 22, 1999, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.

Amendments