§63.1158. Emission standards for new or reconstructed sources.
40 C.F.R. § 63.1158
Pickling lines—
Continuous pickling lines. No owner or operator of a new or reconstructed affected continuous pickling line at a steel pickling facility shall cause or allow to be discharged into the atmosphere from the affected pickling line:
Any gases that contain HCl in a concentration in excess of 6 ppmv; or
HCl at a mass emission rate that corresponds to a collection efficiency of less than 99 percent.
Batch pickling lines. No owner or operator of a new or reconstructed affected batch pickling line at a steel pickling facility shall cause or allow to be discharged into the atmosphere from the affected pickling line:
Any gases that contain HCl in a concentration in excess of 18 ppmv; or
HCl at a mass emission rate that corresponds to a collection efficiency of less than 97 percent.
Hydrochloric acid regeneration plants.
No owner or operator of a new or reconstructed affected plant shall cause or allow to be discharged into the atmosphere from the affected plant any gases that contain HCl in a concentration greater than 12 ppmv.
In addition to the requirement of paragraph (b)(1) of this section, no owner or operator of a new or reconstructed affected plant shall cause or allow to be discharged into the atmosphere from the affected plant any gases that contain Cl2 in a concentration in excess of 6 ppmv.
Notes, amendments, and revision history
Source
Source: 64 FR 33218, June 22, 1999, unless otherwise noted.
Authority
Authority: 42 U.S.C. 7401 et seq.
Source