§62.14745a. What must I do if I close my air curtain incinerator and then restart it?

40 C.F.R. § 62.14745a

(a)
If you close your incinerator but will reopen it prior to the final compliance date in this subpart, you must comply with the final standards in this subpart on January 10, 2025.
(b)
If you close your incinerator but will restart it after January 10, 2025, you must complete emission control retrofits and meet the emission limitations under this subpart on the date your incinerator restarts operation.
Notes, amendments, and revision history

Source

Source: 89 FR 100104, Dec. 11, 2024, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 43 FR 51393, Nov. 3, 1978, unless otherwise noted.

§62.14750a. What must I do if I plan to permanently close my air curtain incinerator and not restart it?

40 C.F.R. § 62.14750a

If you plan to permanently close your incinerator rather than comply with this subpart, submit a closure notification, including the date of closure, to the Administrator no later than six months prior to the date your operation will cease. The closure date cannot be later than January 10, 2025, for sources that will not operate on and after the compliance date under this subpart. In addition, while still in operation, your air curtain incinerator is subject to the same requirement to apply for and obtain an operating permit under title V of the Clean Air Act that applies to an air curtain incinerator that will not be permanently closing.
Notes, amendments, and revision history

Source

Source: 89 FR 100104, Dec. 11, 2024, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 43 FR 51393, Nov. 3, 1978, unless otherwise noted.

§62.14755a. What are the emission limitations for air curtain incinerators?

40 C.F.R. § 62.14755a

After the date the initial test for opacity is required or completed (whichever is earlier), you must meet the limitations in paragraphs (a) and (b) of this section.
(a)
Maintain opacity to less than or equal to 10 percent opacity (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values), except as described in paragraph (b) of this section.
(b)
Maintain opacity to less than or equal to 35 percent opacity (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values) during the startup period that is within the first 30 minutes of operation.
Notes, amendments, and revision history

Source

Source: 89 FR 100104, Dec. 11, 2024, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 43 FR 51393, Nov. 3, 1978, unless otherwise noted.

§62.14760a. How must I monitor opacity for air curtain incinerators?

40 C.F.R. § 62.14760a

(a)
Use Method 9 of 40 CFR part 60, appendix A-4, to determine compliance with the opacity limitation.
(b)
Conduct an initial test for opacity as specified in § 60.8 of this chapter no later than 180 days after your final compliance date under this subpart.
(c)
After the initial test for opacity, conduct annual tests no more than 12 calendar months following the date of your previous test.
Notes, amendments, and revision history

Source

Source: 89 FR 100104, Dec. 11, 2024, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source

Source: 43 FR 51393, Nov. 3, 1978, unless otherwise noted.

§62.14765a. What are the recordkeeping and reporting requirements for air curtain incinerators?

40 C.F.R. § 62.14765a

(a)
Keep records of results of all initial and annual opacity tests onsite in either paper copy or electronic format, unless the Administrator approves another format, for at least 5 years.
(b)
Make all records available for submittal to the Administrator or for an inspector's onsite review.
(c)
Submit an initial report no later than 60 days following the initial opacity test that includes the information specified in paragraphs (c)(1) and (2) of this section.
(1)
The types of materials you plan to combust in your ACI; and
(2)
The results (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values) of the initial opacity tests.
(d)
Submit annual opacity test results within 12 months following the previous report.
(e)
Submit initial and annual opacity test reports as electronic or paper copy on or before the applicable submittal date and keep a copy onsite for a period of 5 years.
Notes, amendments, and revision history

Source

Source: 89 FR 100104, Dec. 11, 2024, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.

Source