§62.14755a. What are the emission limitations for air curtain incinerators?

40 C.F.R. § 62.14755a

After the date the initial test for opacity is required or completed (whichever is earlier), you must meet the limitations in paragraphs (a) and (b) of this section.
(a)
Maintain opacity to less than or equal to 10 percent opacity (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values), except as described in paragraph (b) of this section.
(b)
Maintain opacity to less than or equal to 35 percent opacity (as determined by the average of three 1-hour blocks consisting of ten 6-minute average opacity values) during the startup period that is within the first 30 minutes of operation.
Notes, amendments, and revision history

Source

Source: 89 FR 100104, Dec. 11, 2024, unless otherwise noted.

Authority

Authority: 42 U.S.C. 7401 et seq.