§159.53. General requirements.

33 C.F.R. § 159.53

A device must:
(a)
Under the test conditions described in §§ 159.123 and 159.125, produce an effluent having a fecal coliform bacteria count not greater than 1,000 per 100 milliliters and no visible floating solids (Type I),
(b)
Under the test conditions described in §§ 159.126 and 159.126a, produce an effluent having a fecal coliform bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150 milligrams per liter (Type II), or
(c)
Be designed to prevent the overboard discharge of treated or untreated sewage or any waste derived from sewage (Type III).
Notes, amendments, and revision history

Amendments

[CGD 73-83, 40 FR 4624, Jan. 30, 1975, as amended by CGD 75-213, 41 FR 15325, Apr. 12, 1976]

Authority

Authority: 33 U.S.C. 1322(b)(1); 49 CFR 1.45(b). Subpart E also issued under authority of sec. 1(a)(4), Pub. L. 106-554, 114 Stat. 2763; DHS Delegation No. 00170.1, Revision No. 01.4.

Source

Source: CGD 73-83, 40 FR 4624, Jan. 30, 1975, unless otherwise noted.

Amendments

[CGD 73-83, 40 FR 4624, Jan. 30, 1975, as amended by CGD 75-213, 41 FR 15325, Apr. 12, 1976]