§25.1723. Flammable fluid fire protection: EWIS.
14 C.F.R. § 25.1723
EWIS components located in each area where flammable fluid or vapors might escape by leakage of a fluid system must be considered a potential ignition source and must meet the requirements of § 25.863.
Notes, amendments, and revision history
Source
Source: Docket No. FAA-2004-18379, 72 FR 63406, Nov. 8, 2007, unless otherwise noted.
Authority
Authority: 49 U.S.C. 106(f), 106(g), 40113, 44701, 44702 and 44704; Pub. L. 115-254, 132 Stat 3281 (49 U.S.C. 44903 note).
Source
Source: Docket No. 5066, 29 FR 18291, Dec. 24, 1964, unless otherwise noted.