§572.43. Lumbar spine and pelvis. — Inbound Citations
49 C.F.R. § 572.43
Statutory Authority
Cited by 1 regulation in release Current.
Citations to 49 U.S.C. § 572.43 as a whole
-
(h) For the performance of tests specified in §§ 572.42 and 572.43, the dummy is positioned as follows:(1) The dummy is placed on a flat, rigid, clean, dry, horizontal smooth aluminum surface whose length and width dimensions are not less than 16 inches, so that the dummy's midsagittal plane is vertical and centered on the test surface. The dummy's torso is positioned to meet the requirements of § 572.42 and § 572.43. The seating surface is without the back support and the test dummy is positioned so that the dummy's midsagittal plane is vertical and centered on the seat surface.(3) Performance pre-tests of the assembled dummy are separated in time by a period of not less than 20 minutes unless otherwise specified.(4) Surfaces of the dummy components are not painted except as specified in this part or in drawings subtended by this part.