§238.115. Emergency lighting. — Inbound Citations

49 C.F.R. § 238.115

Cited by 7 regulations in release Current.

Citations to 49 C.F.R. § 238.115 as a whole

Citations to §238.115(a)(1)

  • (a) Prior to January 1, 2017, the requirements specified in paragraphs (a)(1) through (4) of this section apply to each passenger car ordered on or after September 8, 2000, or placed in service for the first time on or after September 9, 2002. Emergency lighting shall be provided in each passenger car and shall include the following:
    (1) A minimum, average illumination level of 1 foot-candle measured at floor level adjacent to each exterior door and each interior door providing access to an exterior door (such as a door opening into a vestibule);
    (2) A minimum, average illumination level of 1 foot-candle measured 25 inches above floor level along the center of each aisle and passageway;
    (3) A minimum illumination level of 0.1 foot-candle measured 25 inches above floor level at any point along the center of each aisle and passageway; and
    (i) Operating in all equipment orientations within 45 degrees of vertical;
    (ii) Operating after the initial shock of a collision or derailment resulting in the following individually applied accelerations:
    (A) 8g;
    (B) 4g; and
    (C) 4g; and
    (iii) Operating all emergency lighting for a period of at least 90 minutes without a loss of more than 40% of the minimum illumination levels specified in this paragraph (a).

Citations to §238.115(a)(2)

  • (a) Prior to January 1, 2017, the requirements specified in paragraphs (a)(1) through (4) of this section apply to each passenger car ordered on or after September 8, 2000, or placed in service for the first time on or after September 9, 2002. Emergency lighting shall be provided in each passenger car and shall include the following:
    (1) A minimum, average illumination level of 1 foot-candle measured at floor level adjacent to each exterior door and each interior door providing access to an exterior door (such as a door opening into a vestibule);
    (2) A minimum, average illumination level of 1 foot-candle measured 25 inches above floor level along the center of each aisle and passageway;
    (3) A minimum illumination level of 0.1 foot-candle measured 25 inches above floor level at any point along the center of each aisle and passageway; and
    (i) Operating in all equipment orientations within 45 degrees of vertical;
    (ii) Operating after the initial shock of a collision or derailment resulting in the following individually applied accelerations:
    (A) 8g;
    (B) 4g; and
    (C) 4g; and
    (iii) Operating all emergency lighting for a period of at least 90 minutes without a loss of more than 40% of the minimum illumination levels specified in this paragraph (a).

Citations to §238.115(a)(3)

  • (a) Prior to January 1, 2017, the requirements specified in paragraphs (a)(1) through (4) of this section apply to each passenger car ordered on or after September 8, 2000, or placed in service for the first time on or after September 9, 2002. Emergency lighting shall be provided in each passenger car and shall include the following:
    (1) A minimum, average illumination level of 1 foot-candle measured at floor level adjacent to each exterior door and each interior door providing access to an exterior door (such as a door opening into a vestibule);
    (2) A minimum, average illumination level of 1 foot-candle measured 25 inches above floor level along the center of each aisle and passageway;
    (3) A minimum illumination level of 0.1 foot-candle measured 25 inches above floor level at any point along the center of each aisle and passageway; and
    (i) Operating in all equipment orientations within 45 degrees of vertical;
    (ii) Operating after the initial shock of a collision or derailment resulting in the following individually applied accelerations:
    (A) 8g;
    (B) 4g; and
    (C) 4g; and
    (iii) Operating all emergency lighting for a period of at least 90 minutes without a loss of more than 40% of the minimum illumination levels specified in this paragraph (a).

Citations to §238.115(a)(4)

  • (a) Prior to January 1, 2017, the requirements specified in paragraphs (a)(1) through (4) of this section apply to each passenger car ordered on or after September 8, 2000, or placed in service for the first time on or after September 9, 2002. Emergency lighting shall be provided in each passenger car and shall include the following:
    (1) A minimum, average illumination level of 1 foot-candle measured at floor level adjacent to each exterior door and each interior door providing access to an exterior door (such as a door opening into a vestibule);
    (2) A minimum, average illumination level of 1 foot-candle measured 25 inches above floor level along the center of each aisle and passageway;
    (3) A minimum illumination level of 0.1 foot-candle measured 25 inches above floor level at any point along the center of each aisle and passageway; and
    (i) Operating in all equipment orientations within 45 degrees of vertical;
    (ii) Operating after the initial shock of a collision or derailment resulting in the following individually applied accelerations:
    (A) 8g;
    (B) 4g; and
    (C) 4g; and
    (iii) Operating all emergency lighting for a period of at least 90 minutes without a loss of more than 40% of the minimum illumination levels specified in this paragraph (a).