§236.106. Relays.
49 C.F.R. § 236.106
Each relay, the functioning of which affects the safety of train operations, shall be tested at least once every four years except:
Alternating current centrifugal type relay shall be tested at least once every 12 months;
Alternating current vane type relay and direct current polar type relay shall be tested at least once every 2 years; and
Relay with soft iron magnetic structure shall be tested at least once every 2 years.