§234.213. Grounds.
49 C.F.R. § 234.213
General. Except as provided in paragraph (b) of this section, each circuit that affects the proper functioning of a highway-rail grade crossing warning system shall be kept free of any ground or combination of grounds that will permit a current flow of 75 percent or more of the value necessary to retain a permissive state of a safety appliance.
Exception. Paragraph (a) of this section does not apply to the following:
Circuits that include track rail;
Alternating current power distribution circuits that are grounded in the interest of safety;
Circuitry internal to microprocessor-based appliances;
Circuitry internal to semiconductor-based memory; and
Common return wires of grounded common return single break circuits.