§230.70. Safe condition.

49 C.F.R. § 230.70

(a)
Pre-departure inspection. At the beginning of each day the locomotive is used, the steam locomotive operator shall ensure that:
(1)
The brakes on the steam locomotive and tender are in safe and suitable condition for service;
(2)
The air compressor or compressors are in condition to provide an ample supply of air for the locomotive service intended;
(3)
The devices for regulating all pressures are properly performing their functions;
(4)
The brake valves work properly in all positions; and
(5)
The water has been drained from the air-brake system.
(b)
Brake pipe valve required. Each steam locomotive shall have a brake pipe valve attached to the front of the tender, the rear of the back cab wall, or adjacent to the exit of a vestibuled cab. The words “Emergency Brake Valve” shall be clearly displayed near the valve.
Notes, amendments, and revision history

Authority

Authority: 49 U.S.C. 20103, 20107, 20702; 28 U.S.C. 2461 note; and 49 CFR 1.89.

Source

Source: 64 FR 62865, Nov. 17, 1999, unless otherwise noted.