§195.571. What criteria must I use to determine the adequacy of cathodic protection? — Inbound Citations

49 C.F.R. § 195.571

Cited by 4 regulations in release Current.

Citations to 49 U.S.C. § 195.571 as a whole

  • (2) NACE SP0169-2007, Standard Practice, Control of External Corrosion on Underground or Submerged Metallic Piping Systems, reaffirmed March 15, 2007, (NACE SP0169), IBR approved for §§ 195.571; 195.573(a).
  • (1) Has cathodic protection that substantially meets § 195.571 before the pipeline is placed in service; or
  • (c) You must maintain the test lead wires in a condition that enables you to obtain electrical measurements to determine whether cathodic protection complies with § 195.571.
  • (a) You must do the following to determine whether cathodic protection required by this subpart complies with § 195.571:
    (1) Conduct tests on the protected pipeline at least once each calendar year, but with intervals not exceeding 15 months. However, if tests at those intervals are impractical for separately protected short sections of bare or ineffectively coated pipelines, testing may be done at least once every 3 calendar years, but with intervals not exceeding 39 months.
    (2) Identify not more than 2 years after cathodic protection is installed, the circumstances in which a close-interval survey or comparable technology is practicable and necessary to accomplish the objectives of paragraph 10.1.1.3 of NACE SP 0169 (incorporated by reference, see § 195.3).