US Codex
C.F.R.
Browse by date
Notes

§195.569. Do I have to examine exposed portions of buried pipelines?

49 C.F.R. § 195.569

Whenever you have knowledge that any portion of a buried pipeline is exposed, you must examine the exposed portion for evidence of external corrosion if the pipe is bare, or if the coating is deteriorated. If you find external corrosion requiring corrective action under § 195.585, you must investigate circumferentially and longitudinally beyond the exposed portion (by visual examination, indirect method, or both) to determine whether additional corrosion requiring remedial action exists in the vicinity of the exposed portion.
Notes, amendments, and revision history

Source

Source: Amdt. 195-73, 66 FR 67004, Dec. 27, 2001, unless otherwise noted.

Authority

Authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et seq., and 49 CFR 1.97.

Source

Source: Amdt. 195-22, 46 FR 38360, July 27, 1981, unless otherwise noted.