US Codex
C.F.R.
Browse by date
Notes

§195.56. Filing safety-related condition reports. — Inbound Citations

49 C.F.R. § 195.56

Cited by 2 regulations in release Current.

Citations to 49 C.F.R. § 195.56 as a whole

  • (a) Except as provided in paragraph (b) of this section, each operator shall report in accordance with § 195.56 the existence of any of the following safety-related conditions involving pipelines in service:
    (1) General corrosion that has reduced the wall thickness to less than that required for the maximum operating pressure, and localized corrosion pitting to a degree where leakage might result.
    (2) Unintended movement or abnormal loading of a pipeline by environmental causes, such as an earthquake, landslide, or flood, that impairs its serviceability.
    (4) Any malfunction or operating error that causes the pressure of a pipeline to rise above 110 percent of its maximum operating pressure.
    (6) Any safety-related condition that could lead to an imminent hazard and causes (either directly or indirectly by remedial action of the operator), for purposes other than abandonment, a 20 percent or more reduction in operating pressure or shutdown of operation of a pipeline.
  • (b) An operator is not required to submit a safety-related condition report (§ 195.56) electronically.