§195.205. Repair, alteration and reconstruction of aboveground breakout tanks that have been in service. — Inbound Citations
49 C.F.R. § 195.205
Statutory Authority
Cited by 2 regulations in release Current.
Citations to §195.205(b)
-
(c) Breakout tanks that are subject to this part must comply with requirements that apply specifically to breakout tanks and, to the extent applicable, with requirements that apply to pipeline systems and pipeline facilities. If a conflict exists between a requirement that applies specifically to breakout tanks and a requirement that applies to pipeline systems or pipeline facilities, the requirement that applies specifically to breakout tanks prevails. Anhydrous ammonia breakout tanks need not comply with §§ 195.132(b); 195.205(b); 195.264(b) and (e); 195.307; 195.428(c) through (d); and 195.432(b) and (c).
-
(1) In-service Inspection, Rating, Repair, and Alteration, 10th Edition, May 2014, Including Addendum 1 (May 2017); IBR approved for §§ 195.205(b); 195.432(c).