§192.711. Transmission lines: General requirements for repair procedures.
49 C.F.R. § 192.711
Temporary repairs. Each operator must take immediate temporary measures to protect the public whenever:
A leak, imperfection, or damage that impairs its serviceability is found in a segment of steel transmission line operating at or above 40 percent of the SMYS; and
It is not feasible to make a permanent repair at the time of discovery.
Permanent repairs. An operator must make permanent repairs on its pipeline system according to the following:
Non-integrity management repairs for gathering lines and offshore transmission lines— For gathering lines subject to this section in accordance with § 192.9 and for offshore transmission lines, an operator must make permanent repairs as soon as feasible.
Non-integrity management repairs for onshore transmission lines— Except for gathering lines exempted from this section in accordance with § 192.9 and offshore transmission lines, after May 24, 2023, whenever an operator discovers any condition that could adversely affect the safe operation of a pipeline segment not covered by an integrity management program under subpart O of this part, it must correct the condition as prescribed in § 192.714.
Integrity management repairs— When an operator discovers a condition on a pipeline covered under Subpart O-Gas Transmission Pipeline Integrity Management, the operator must remediate the condition as prescribed by § 192.933(d).
Welded patch. Except as provided in § 192.717(b)(3), no operator may use a welded patch as a means of repair.
Notes, amendments, and revision history
Amendments
[Amdt. 192-114, 75 FR 48604, Aug. 11, 2010, as amended by Amdt. 192-132, 87 FR 52270, Aug. 24, 2022]
Authority
Authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et. seq., and 49 CFR 1.97.
Source
Source: 35 FR 13257, Aug. 19, 1970, unless otherwise noted.
Amendments
[Amdt. 192-114, 75 FR 48604, Aug. 11, 2010, as amended by Amdt. 192-132, 87 FR 52270, Aug. 24, 2022]