US Codex
C.F.R.
Browse by date
Notes

§192.489. Remedial measures: Cast iron and ductile iron pipelines.

49 C.F.R. § 192.489

(a)
General graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a degree where a fracture or any leakage might result, must be replaced.
(b)
Localized graphitization. Each segment of cast iron or ductile iron pipe on which localized graphitization is found to a degree where any leakage might result, must be replaced or repaired, or sealed by internal sealing methods adequate to prevent or arrest any leakage.
Notes, amendments, and revision history

Source

Source: Amdt. 192-4, 36 FR 12302, June 30, 1971, unless otherwise noted.

Authority

Authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103, 60101 et. seq., and 49 CFR 1.97.

Source

Source: 35 FR 13257, Aug. 19, 1970, unless otherwise noted.