§192.463. External corrosion control: Cathodic protection. — Inbound Citations
49 C.F.R. § 192.463
Statutory Authority
Cited by 4 regulations in release Current.
Citations to 49 C.F.R. § 192.463 as a whole
-
(a) Each pipeline that is under cathodic protection must be tested at least once each calendar year, but with intervals not exceeding 15 months, to determine whether the cathodic protection meets the requirements of § 192.463. However, if tests at those intervals are impractical for separately protected short sections of mains or transmission lines, not in excess of 100 feet (30 meters), or separately protected service lines, these pipelines may be surveyed on a sampling basis. At least 10 percent of these protected structures, distributed over the entire system must be surveyed each calendar year, with a different 10 percent checked each subsequent year, so that the entire system is tested in each 10-year period.
-
(G) Perform a coating survey of the eligible Class 3 segment and remediate in accordance with the requirements in § 192.461(f) through (h) if any of the following in paragraphs (a)(4)(i)(1) through (5) are present:(1) Ineffective external coating, as defined in § 192.457;(2) Adequacy of cathodic protection is measured using a minimum negative (cathodic) polarization voltage shift of 100 millivolts in accordance with paragraph I.A.(3) of appendix D to this part;(3) Linear anodes are required to maintain cathodic protection in accordance with § 192.463;(4) Tape wraps or shrink sleeves; or(5) A history of shielding pipe from cathodic protection.
-
(ii) A cathodic protection system designed to protect components in their entirety in accordance with the requirements of § 192.463 of this chapter and placed in operation before October 23, 1981, or within 1 year after the component is constructed or installed, whichever is later.
-
(a) Each buried or submerged component under cathodic protection must be tested at least once each calendar year, but with intervals not exceeding 15 months, to determine whether the cathodic protection meets the requirements of § 192.463 of this chapter.