§192.243. Nondestructive testing. — Inbound Citations
49 C.F.R. § 192.243
Statutory Authority
Cited by 3 regulations in release Current.
Citations to 49 C.F.R. § 192.243 as a whole
-
(b) The welds on a pipeline to be operated at a pressure that produces a hoop stress of 20 percent or more of SMYS must be nondestructively tested in accordance with § 192.243, except that welds that are visually inspected and approved by a qualified welding inspector need not be nondestructively tested if:(1) The pipe has a nominal diameter of less than 6 inches (152 millimeters); or(2) The pipeline is to be operated at a pressure that produces a hoop stress of less than 40 percent of SMYS and the welds are so limited in number that nondestructive testing is impractical.
Citations to §192.243(b)
-
(7) At least 95 percent of girth welds on a segment that was constructed prior to December 22, 2008, must have been non-destructively examined in accordance with § 192.243(b) and (c).
Citations to §192.243(c)
-
(7) At least 95 percent of girth welds on a segment that was constructed prior to December 22, 2008, must have been non-destructively examined in accordance with § 192.243(b) and (c).