US Codex
C.F.R.
Browse by date
Notes

§179.300-14. Attachments not otherwise specified.

49 C.F.R. § 179.300-14

Siphon pipes and their couplings on the inside of the tank head and lugs on the outside of the tank head for attaching the valve protective housing must be fusion-welded in place prior to postweld heat treatment. All other fixtures and appurtenances, except as specifically provided for, are prohibited.
Notes, amendments, and revision history

Amendments

[Amdt. 179-10, 36 FR 21355, Nov. 6, 1971]

Authority

Authority: 49 U.S.C. 5101-5128; 49 CFR 1.81 and 1.97.

Source

Source: 29 FR 18995, Dec. 29, 1964, unless otherwise noted. Redesignated at 32 FR 5606, Apr. 5, 1967.

Amendments

[Amdt. 179-10, 36 FR 21355, Nov. 6, 1971]