§178.813. Leakproofness test. — Inbound Citations

49 C.F.R. § 178.813

Cited by 2 regulations in release Current.

Citations to 49 C.F.R. § 178.813 as a whole

  • (1) Production testing consists of the leakproofness test prescribed in § 178.813 of this subpart and must be performed on each IBC intended to contain solids discharged by pressure or intended to contain liquids. For this test:
    (i) The IBC need not have its closures fitted, except that the IBC must be fitted with its primary bottom closure.
    (ii) The inner receptacle of a composite IBC may be tested without the outer IBC body, provided the test results are not affected.
  • (1) Each IBC intended to contain solids that are loaded or discharged under pressure or intended to contain liquids must be tested in accordance with the leakproofness test prescribed in § 178.813 of this subchapter prior to its first use in transportation and every 2.5 years thereafter, starting from the date of manufacture or the date of a repair conforming to paragraph (d)(1) of this section. For this test, the IBC is not required to have its closures fitted.