§173.306. Limited quantities of compressed gases. — Inbound Citations

49 C.F.R. § 173.306

Cited by 20 regulations in release Current.

Citations to 49 C.F.R. § 173.306 as a whole

  • (3) Filled, marked, and inspected in accordance with 49 CFR 173.301 through 173.308; and
  • (1) ANSI/ASHRAE Standard 15-1994, Safety Code for Mechanical Refrigeration, 1994, into §§ 173.306; 173.307.
  • (b) Packagings for limited quantity materials are specified according to hazard class in §§ 173.150 through 173.155, 173.306, and 173.309(b). In addition to exceptions provided for limited quantity materials elsewhere in this part, the following are provided:
    (1) Strong outer packagings as specified in this part, marking requirements specified in subpart D of part 172 of this subchapter, and the 30 kg (66 pounds) gross weight limitation when—
    (i) Unitized in cages, carts, boxes or similar overpacks;
    (A) Rail;
    (B) Private or contract motor carrier; or
    (C) Common carrier in a vehicle under exclusive use for such service; and
    (iii) Transported to or from a manufacturer, a distribution center, or a retail outlet, or transported to a disposal facility from one offeror.
    (2) The 30 kg (66 pounds) gross weight limitation does not apply to packages of limited quantity materials marked in accordance with § 172.315 of this subchapter when offered for transportation or transported by highway or rail between a manufacturer, a distribution center, and a retail outlet provided—
    (i) Inner packagings conform to the quantity limits for inner packagings specified in §§ 173.150(b), 173.152(b), 173.154(b), 173.155(b), 173.306(a) and (b), and 173.309(b), as appropriate;
    (ii) The inner packagings are packed into corrugated fiberboard trays to prevent them from moving freely;
    (iii) The trays are placed in a fiberboard box which is banded and secured to a metal, plastic, composite, or wooden pallet by metal, fabric, or plastic straps, to form a single palletized unit. Hazardous materials should be compatible with the pallet material;
    (iv) The package conforms to the general packaging requirements of subpart B of this part; and
    (v) The maximum net quantity of hazardous material permitted on one palletized unit is 250 kg (550 pounds).
  • (i) Non-toxic aerosols, as defined in § 171.8 of this subchapter and constructed in accordance with § 173.306 of this part, in non-refillable, non-metal containers not exceeding 120 mL (4 fluid ounces) each, or in non-refillable metal containers not exceeding 820 mL (28 fluid ounces) each, except that flammable aerosols may not exceed 500 mL (16.9 fluid ounces) each;
  • (2) Filling limits for compressed gases and cryogenic liquids are specified in §§ 173.301 through 173.306 for cylinders and §§ 173.314 through 173.319 for bulk packagings.
    (i) Except as provided in subpart C of part 171 of this subchapter, packages prepared under § 173.167 of this part, or packages prepared under Packing Instruction Y963 of the ICAO Technical Instructions, packages offered or intended for transportation by aircraft must conform to the general requirements for transportation by aircraft in § 173.27.
  • (4) Each fire extinguisher must be tested, without evidence of failure or damage, to at least three times its charged pressure at 21 °C (70 °F) but not less than 825 kPa (120 psig) before initial shipment, and must be marked to indicate the year of the test (within 90 days of the actual date of the original test) and with the words “MEETS DOT REQUIREMENTS.” This marking is considered a certification that the fire extinguisher is manufactured in accordance with the requirements of this section. The words “This extinguisher meets all requirements of 49 CFR 173.306” may be displayed on fire extinguishers manufactured prior to January 1, 1976;

Citations to §173.306(a)

Citations to §173.306(a)(1)

  • (1) Except for a limited quantity of a compressed gas in a container of not more than 4 fluid ounces capacity meeting the requirements in § 173.306(a)(1) of this subchapter, the proper shipping name “Aerosol,” UN1950, may be used only for a non-refillable receptacle containing a gas compressed, liquefied, or dissolved under pressure the sole purpose of which is to expel a nonpoisonous (other than Division 6.1, Packing Group III material) liquid, paste, or powder and fitted with a self-closing release device (see § 171.8). In addition, an aerosol must be in a metal packaging when the packaging exceeds 7.22 cubic inches.

Citations to §173.306(a)(3)(v)

Citations to §173.306(b)

Citations to §173.306(e)(1)

  • (i) Reconditioned (used) refrigerating machines (UN 2857, Div. 2.2) may be excepted from the marking requirements of § 172.302(c) of this subchapter and transported by motor vehicle when they conform to the requirements prescribed in § 173.306(e)(1), are secured or permanently attached to the motor vehicle, and are:
    (A) Permanently affixed to a steel base structure,
    (B) Permanently affixed to a trailer, or
    (C) Manufactured with a rigid internal structure designed for transportation and stacking conditions such that they do not leak and do not deteriorate, distort, or become damaged in a manner that could adversely affect their safety or reduce their strength in transportation, cause instability in stacks of refrigerating machines, or cause damage to these machines in a way that is likely to reduce safety in transportation.

Citations to §173.306(f)(1)

Citations to §173.306(f)(2)

Citations to §173.306(f)(3)

Citations to §173.306(f)(4)

Citations to §173.306(f)(4)(i)

Citations to §173.306(f)(4)(ii)

Citations to §173.306(f)(4)(iii)

Citations to §173.306(h)

Citations to §173.306(i)