§173.24b. Additional general requirements for bulk packagings. — Inbound Citations

49 C.F.R. § 173.24b

Cited by 7 regulations in release Current.

Citations to 49 U.S.C. § 173.24b as a whole

  • (a) A pesticide product that does not meet the definition of a hazardous material in 49 CFR 171.8 must be packaged in a nonrefillable container that, if portable, is designed, constructed, and marked to comply with the requirements of 49 CFR 173.4, 173.5, 173.6, 173.24, 173.24a, 173.24b, 173.28, 173.155, 173.203, 173.213, 173.240(c), 173.240(d), 173.241(c), 173.241(d), part 178, and part 180 that are applicable to a Packing Group III material, or, if subject to a special permit, according to the applicable requirements of 49 CFR part 107 subpart B. The requirements in this paragraph apply to the pesticide product as it is packaged for transportation in commerce.
  • (1) A pesticide product that does not meet the definition of a hazardous material in 49 CFR 171.8 must be packaged in a refillable container that, if portable, is designed, constructed, and marked to comply with the requirements of 49 CFR 173.4, 173.5, 173.6, 173.24, 173.24a, 173.24b, 173.28, 173.155, 173.203, 173.213, 173.240(c), 173.240(d), 173.241(c), 173.241(d), part 178, and part 180 that are applicable to a Packing Group III material, or, if subject to a special permit, according to the applicable requirements of 49 CFR part 107 subpart B. The requirements in this paragraph apply to the pesticide product as it is packaged for transportation in commerce.
  • (viii) The requirements of §§ 173.1, 173.21, 173.24, 173.24a, 173.24b, 174.1, 177.804, 177.817, 177.834(j), and 177.837(d) of this subchapter;
  • (c) Except as otherwise provided, the loading of a liquefied gas into a cargo tank or portable tank shall be determined by weight or by a suitable liquid level gauging device. The vapor pressure (psig) at 115 °F. must not exceed the design pressure of the cargo tank or portable tank container. The outage and filling limits for liquefied gases must be as prescribed in § 173.24b of this part, except that this requirement does not apply to:
    (1) Such tank is required to be equipped with suitable pressure control valves and may not be filled to a level exceeding 95 percent of the volumetric capacity of the tank.
    (2) Such tank must be filled to allow at least two percent outage below the inlet of the pressure relief valve or pressure control valve under conditions of incipient opening, with the tank in a level attitude.
  • (d) Notwithstanding requirements in § 173.24b of this subpart, when filling an IBC with liquids, sufficient ullage must be left to ensure that, at the mean bulk temperature of 50 °C (122 °F), the IBC is not filled to more than 98 percent of its water capacity.
  • (f) The package will be capable of withstanding the effects of any acceleration, vibration or vibration resonance that may arise under normal conditions of transport without any deterioration in the effectiveness of the closing devices on the various receptacles or in the integrity of the package as a whole and without loosening or unintentionally releasing the nuts, bolts, or other securing devices even after repeated use (see §§ 173.24, 173.24a, and 173.24b).

Citations to §173.24b(a)

  • (1) When filling packagings and receptacles for liquids, sufficient ullage (outage) must be left to ensure that neither leakage nor permanent distortion of the packaging or receptacle will occur as a result of an expansion of the liquid caused by temperatures likely to be encountered during transportation. Requirements for outage and filling limits for non-bulk and bulk packagings are specified in §§ 173.24a(d) and 173.24b(a), respectively.