§173.224. Packaging and control and emergency temperatures for self-reactive materials.
49 C.F.R. § 173.224
(1) The samples are carried in microtiter plates or multi-titer plates made of plastics, glass, porcelain or stoneware as an inner packaging;
(2) only combination packaging with outer packaging comprising boxes (4A, 4B, 4N, 4C1, 4C2, 4D, 4F, 4G, 4H1 and 4H2) are permitted; or
(1) The individual substance is contained in an inner packaging of glass or plastics of maximum capacity of 30 mL placed in an expandable polyethylene foam matrix of at least 130 mm thickness having a density of 18 ± 1 g/L;
(2) Within the foam carrier, inner packagings are segregated from each other by a minimum distance of 40 mm and from the wall of the outer packaging by a minimum distance of 70 mm. The package may contain up to two layers of such foam matrices, each carrying up to twenty-eight inner packagings;
(3) The outer packaging consists only of corrugated fiberboard boxes (4G) having minimum dimensions of 60 cm (length) by 40.5 cm (width) by 30 cm (height) and minimum wall thickness of 1.3 cm.
Notes, amendments, and revision history
Amendments
[Amdt. 173-241, 59 FR 67511, Dec. 29, 1994] ]
Source
Source: Amdt. 173-224, 55 FR 52643, Dec. 21, 1990, unless otherwise noted.
Authority
Authority: 49 U.S.C. 5101-5128, 44701; 49 CFR 1.81, 1.96 and 1.97.
Amendments
[Amdt. 173-241, 59 FR 67511, Dec. 29, 1994] ]