§95.3205. Unwanted emissions limits.
47 C.F.R. § 95.3205
C-V2X OBUs must comply with the following out-of-band emissions limits. Conducted emissions limits measured at the antenna input shall not exceed:
−16 dBm/100 kHz within ±1 megahertz of the band edges;
−13 dBm/MHz within ±1 megahertz to ±5 megahertz of the band edges;
−16 dBm/MHz within ±5 megahertz to ±30 megahertz of the band edges; and
−28 dBm/MHz beyond 30 megahertz from the band edges.
Notes, amendments, and revision history
Amendments
[89 FR 100855, Dec. 13, 2024]
Source
Source: 89 FR 100855, Dec. 13, 2024, unless otherwise noted.
Authority
Authority: 47 U.S.C. 154, 303, 307.
Source
Source: 82 FR 41104, Aug. 29, 2017, unless otherwise noted.
Amendments