§27.804. Field strength limits at WMTS facility.
47 C.F.R. § 27.804
For any operation in the 1392-1395 MHz band, the predicted or measured field strength—into the WMTS band at 1395-1400 MHz—shall not exceed 150 uV/m at the location of any registered WMTS healthcare facility. When performing measurements to determine compliance with this provision, measurement instrumentation employing an average detector and a resolution bandwidth of 1 MHz may be used, provided it accurately represents the true interference potential of the equipment.
Notes, amendments, and revision history
Source
Source: 67 FR 41855, June 20, 2002, unless otherwise noted.
Authority
Authority: 47 U.S.C. 154, 301, 302a, 303, 307, 309, 332, 336, 337, 1403, 1404, 1451, and 1452, unless otherwise noted.
Source