§2.910. Incorporation by reference. — Inbound Citations
47 C.F.R. § 2.910
Statutory Authority
Cited by 7 regulations in release Current.
Citations to 47 C.F.R. § 2.910 as a whole
-
(b) For equipment operating in the authorized radio services, measurements are required as specified in §§ 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055 and 2.1057. The measurement procedures in ANSI C63.26-2015 (incorporated by reference, see § 2.910) are acceptable for performing compliance measurements for equipment types covered by the measurement standard. See also § 2.947 for acceptable measurement procedures.
-
(b) Sections 2.906 through 2.1077 describe the procedure for a Supplier's Declaration of Conformity and the procedures to be followed in obtaining certification and the conditions attendant to such a grant.
-
(d) When the measurement method used requires the testing of radiated emissions on a validated test site, the site attenuation must comply with either: the requirements of ANSI C63.4a-2017 (incorporated by reference, see § 2.910) or the requirements of sections 5.4.4 through 5.5 of ANSI C63.4-2014 (incorporated by reference, see § 2.910).(1) Measurement facilities used to make radiated emission measurements from 30 MHz to 1 GHz must comply with the site validation requirements in either ANSI C63.4a-2017 or ANSI C63.4-2014 (clause 5.4.4);(2) Measurement facilities used to make radiated emission measurements from 1 GHz to 18 GHz must comply with the site validation requirement of ANSI C63.25.1-2018 (incorporated by reference, see § 2.910);(3) Measurement facilities used to make radiated emission measurements from 18 GHz to 40 GHz must comply with the site validation requirement of ANSI C63.4-2014 (clause 5.5.1 a) 1)), such that the site validation criteria called out in CISPR 16-1-4:2010-04 (incorporated by reference, see § 2.910) is met.(4) Test site revalidation must occur on an interval not to exceed three years.
-
(1) Successful completion of an ISO/IEC 17011 (incorporated by reference, see § 2.910) peer review, such as being a signatory to an accreditation agreement that is acceptable to the Commission.
-
(a) Prior to October 30, 2025, a prospective or accredited testing laboratory or telecommunication certification body must be capable of meeting the requirements and conditions of ISO/IEC 17025:2005(E) (incorporated by reference, see § 2.910) or ISO/IEC 17025:2017(E) (incorporated by reference, see § 2.910). On or after October 30, 2025, a prospective or accredited testing laboratory or telecommunication certification body must be capable of meeting the requirements and conditions of ISO/IEC 17025:2017(E) (incorporated by reference, see § 2.910).
-
(4) By means of accreditation specifying the group of equipment to be certified and the applicable regulations for product evaluation, meets all appropriate specifications in ISO/IEC 17065 (incorporated by reference, see § 2.910) for the scope of equipment the TCB would certify.
-
(1) The certification system must be based on type testing as identified in ISO/IEC 17065 (incorporated by reference, see § 2.910).