§2.1053. Measurements required: Field strength of spurious radiation. — Inbound Citations
47 C.F.R. § 2.1053
Statutory Authority
Cited by 5 regulations in release Current.
Citations to 47 U.S.C. § 2.1053 as a whole
-
(14) A photograph or drawing of the equipment identification plate or label showing the information to be placed thereon.
-
(b) For equipment operating in the authorized radio services, measurements are required as specified in §§ 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055 and 2.1057. The measurement procedures in ANSI C63.26-2015 (incorporated by reference, see § 2.910) are acceptable for performing compliance measurements for equipment types covered by the measurement standard. See also § 2.947 for acceptable measurement procedures.
-
(a) In all of the measurements set forth in §§ 2.1051 and 2.1053, the spectrum shall be investigated from the lowest radio frequency signal generated in the equipment, without going below 9 kHz, up to at least the frequency shown below:(1) If the equipment operates below 10 GHz: to the tenth harmonic of the highest fundamental frequency or to 40 GHz, whichever is lower.(2) If the equipment operates at or above 10 GHz and below 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 100 GHz, whichever is lower.(3) If the equipment operates at or above 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 200 GHz, whichever is lower.
-
-
(b) Sections 2.906 through 2.1077 describe the procedure for a Supplier's Declaration of Conformity and the procedures to be followed in obtaining certification and the conditions attendant to such a grant.