§64.59. Spring loaded pressure relief valve.

46 C.F.R. § 64.59

A spring loaded pressure relief valve must—
(a)
Be set at a nominal pressure of 125 percent of the maximum allowable working pressure;
(b)
Have a minimum normal venting capacity that is sufficient to prevent the tank pressure from exceeding 137.5 percent of the maximum allowable working pressure;
(c)
Close after discharge of a pressure not lower than 115 percent of the maximum allowable working pressure; and
(d)
If closed, remain closed at any pressure less than 115 percent of the maximum allowable working pressure.
Notes, amendments, and revision history

Authority

Authority: 46 U.S.C. 3306, 3703; 49 U.S.C. App. 1804; Department of Homeland Security Delegation No. 00170.1, Revision No. 01.3.