§56.50-45. Circulating pumps.
46 C.F.R. § 56.50-45
A main circulating pump and emergency means for circulating water through the main condenser must be provided. The emergency means may consist of a connection from an independent power pump fitted between the main circulating pump and the condenser.
Independent sea suctions must be provided for the main circulating and the emergency circulating pumps.
A cross connection between the circulating pumps in the case of multiple units will be acceptable in lieu of an independent power pump connection.